ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~

碩士 === 國立臺灣科技大學 === 電子工程系 === 96 === The main subject of this paper is to detect the ECG R wave by using only two uniploar leads and the wireless transmit the heart beat pulse by 5.5KHz frequency. Due to the non-coded transmittion each heart beat will occur a 5.5KHz radio frequency radiation to the...

Full description

Bibliographic Details
Main Authors: Hung-Yuh Su, 蘇鴻裕
Other Authors: Jhin-Fang Huang
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/79056822067801956378
id ndltd-TW-096NTUS5428192
record_format oai_dc
spelling ndltd-TW-096NTUS54281922016-05-13T04:15:17Z http://ndltd.ncl.edu.tw/handle/79056822067801956378 ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ 兩點式心跳R波信號取出與5.5KHz無編碼無綫傳輸設計~以電動跑步機應用為例~ Hung-Yuh Su 蘇鴻裕 碩士 國立臺灣科技大學 電子工程系 96 The main subject of this paper is to detect the ECG R wave by using only two uniploar leads and the wireless transmit the heart beat pulse by 5.5KHz frequency. Due to the non-coded transmittion each heart beat will occur a 5.5KHz radio frequency radiation to the receiver side, the receiver receives the radiation pulse then form as a square wave for console calculation to count the heart rate value. By the experiments found that the textile chest belt design could have more stable heart signal pick-up, more comfortable for long-time wearing so that more suit for the using of sporting purpose. The detail analysis and considerations for each section of the system such as the pair resonation of conductance and capacitance design and the sponge added under the receiver module PCB board as a damping effect which can reduce mechanical vibration which makes the system more reliable. The results of the study founds as an application for treadmill wireless transmittion purpose , 5.5KHz radio frequency still is the competitively chose . Jhin-Fang Huang 黃進芳 2008 學位論文 ; thesis 163 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電子工程系 === 96 === The main subject of this paper is to detect the ECG R wave by using only two uniploar leads and the wireless transmit the heart beat pulse by 5.5KHz frequency. Due to the non-coded transmittion each heart beat will occur a 5.5KHz radio frequency radiation to the receiver side, the receiver receives the radiation pulse then form as a square wave for console calculation to count the heart rate value. By the experiments found that the textile chest belt design could have more stable heart signal pick-up, more comfortable for long-time wearing so that more suit for the using of sporting purpose. The detail analysis and considerations for each section of the system such as the pair resonation of conductance and capacitance design and the sponge added under the receiver module PCB board as a damping effect which can reduce mechanical vibration which makes the system more reliable. The results of the study founds as an application for treadmill wireless transmittion purpose , 5.5KHz radio frequency still is the competitively chose .
author2 Jhin-Fang Huang
author_facet Jhin-Fang Huang
Hung-Yuh Su
蘇鴻裕
author Hung-Yuh Su
蘇鴻裕
spellingShingle Hung-Yuh Su
蘇鴻裕
ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
author_sort Hung-Yuh Su
title ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
title_short ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
title_full ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
title_fullStr ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
title_full_unstemmed ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
title_sort ecg r wave detection by the way of two uni-polar and 5.5khz non-coded radio frequency wireless tansmittion ~ as an example of treadmill application~
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/79056822067801956378
work_keys_str_mv AT hungyuhsu ecgrwavedetectionbythewayoftwounipolarand55khznoncodedradiofrequencywirelesstansmittionasanexampleoftreadmillapplication
AT sūhóngyù ecgrwavedetectionbythewayoftwounipolarand55khznoncodedradiofrequencywirelesstansmittionasanexampleoftreadmillapplication
AT hungyuhsu liǎngdiǎnshìxīntiàorbōxìnhàoqǔchūyǔ55khzwúbiānmǎwúxiànchuánshūshèjìyǐdiàndòngpǎobùjīyīngyòngwèilì
AT sūhóngyù liǎngdiǎnshìxīntiàorbōxìnhàoqǔchūyǔ55khzwúbiānmǎwúxiànchuánshūshèjìyǐdiàndòngpǎobùjīyīngyòngwèilì
_version_ 1718267639539695616