ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~
碩士 === 國立臺灣科技大學 === 電子工程系 === 96 === The main subject of this paper is to detect the ECG R wave by using only two uniploar leads and the wireless transmit the heart beat pulse by 5.5KHz frequency. Due to the non-coded transmittion each heart beat will occur a 5.5KHz radio frequency radiation to the...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2008
|
Online Access: | http://ndltd.ncl.edu.tw/handle/79056822067801956378 |
id |
ndltd-TW-096NTUS5428192 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-096NTUS54281922016-05-13T04:15:17Z http://ndltd.ncl.edu.tw/handle/79056822067801956378 ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ 兩點式心跳R波信號取出與5.5KHz無編碼無綫傳輸設計~以電動跑步機應用為例~ Hung-Yuh Su 蘇鴻裕 碩士 國立臺灣科技大學 電子工程系 96 The main subject of this paper is to detect the ECG R wave by using only two uniploar leads and the wireless transmit the heart beat pulse by 5.5KHz frequency. Due to the non-coded transmittion each heart beat will occur a 5.5KHz radio frequency radiation to the receiver side, the receiver receives the radiation pulse then form as a square wave for console calculation to count the heart rate value. By the experiments found that the textile chest belt design could have more stable heart signal pick-up, more comfortable for long-time wearing so that more suit for the using of sporting purpose. The detail analysis and considerations for each section of the system such as the pair resonation of conductance and capacitance design and the sponge added under the receiver module PCB board as a damping effect which can reduce mechanical vibration which makes the system more reliable. The results of the study founds as an application for treadmill wireless transmittion purpose , 5.5KHz radio frequency still is the competitively chose . Jhin-Fang Huang 黃進芳 2008 學位論文 ; thesis 163 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 電子工程系 === 96 === The main subject of this paper is to detect the ECG R wave by using only two uniploar leads and the wireless transmit the heart beat pulse by 5.5KHz frequency.
Due to the non-coded transmittion each heart beat will occur a 5.5KHz radio frequency radiation to the receiver side, the receiver receives the radiation pulse then form as a square wave for console calculation to count the heart rate value.
By the experiments found that the textile chest belt design could have more stable heart signal pick-up, more comfortable for long-time wearing so that more suit for the using of sporting purpose.
The detail analysis and considerations for each section of the system such as the pair resonation of conductance and capacitance design and the sponge added under the receiver module PCB board as a damping effect which can reduce mechanical vibration which makes the system more reliable.
The results of the study founds as an application for treadmill wireless transmittion purpose , 5.5KHz radio frequency still is the competitively chose .
|
author2 |
Jhin-Fang Huang |
author_facet |
Jhin-Fang Huang Hung-Yuh Su 蘇鴻裕 |
author |
Hung-Yuh Su 蘇鴻裕 |
spellingShingle |
Hung-Yuh Su 蘇鴻裕 ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ |
author_sort |
Hung-Yuh Su |
title |
ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ |
title_short |
ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ |
title_full |
ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ |
title_fullStr |
ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ |
title_full_unstemmed |
ECG R Wave Detection by the Way of Two Uni-polar and 5.5KHz Non-Coded Radio Frequency Wireless Tansmittion ~ As an Example of Treadmill Application~ |
title_sort |
ecg r wave detection by the way of two uni-polar and 5.5khz non-coded radio frequency wireless tansmittion ~ as an example of treadmill application~ |
publishDate |
2008 |
url |
http://ndltd.ncl.edu.tw/handle/79056822067801956378 |
work_keys_str_mv |
AT hungyuhsu ecgrwavedetectionbythewayoftwounipolarand55khznoncodedradiofrequencywirelesstansmittionasanexampleoftreadmillapplication AT sūhóngyù ecgrwavedetectionbythewayoftwounipolarand55khznoncodedradiofrequencywirelesstansmittionasanexampleoftreadmillapplication AT hungyuhsu liǎngdiǎnshìxīntiàorbōxìnhàoqǔchūyǔ55khzwúbiānmǎwúxiànchuánshūshèjìyǐdiàndòngpǎobùjīyīngyòngwèilì AT sūhóngyù liǎngdiǎnshìxīntiàorbōxìnhàoqǔchūyǔ55khzwúbiānmǎwúxiànchuánshūshèjìyǐdiàndòngpǎobùjīyīngyòngwèilì |
_version_ |
1718267639539695616 |