Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption

碩士 === 國立臺灣大學 === 醫學工程學研究所 === 96 === It has been shown that focused ultrasound (FUS) could disrupt local blood-brain barrier (BBB) noninvasively via the injection of ultrasound contrast agent (UCA). In this study, we use single frequency (518kHz) ultrasound and confocal dual frequency (513kHz+523kH...

Full description

Bibliographic Details
Main Authors: Sheng-Kai Wu, 吳聖凱
Other Authors: 林文澧
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/92131000650518674389
id ndltd-TW-096NTU05530035
record_format oai_dc
spelling ndltd-TW-096NTU055300352015-11-25T04:04:36Z http://ndltd.ncl.edu.tw/handle/92131000650518674389 Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption 單頻與共焦雙頻聚焦式超音波配合超音波顯影劑應用於局部血腦屏障開啟之探討 Sheng-Kai Wu 吳聖凱 碩士 國立臺灣大學 醫學工程學研究所 96 It has been shown that focused ultrasound (FUS) could disrupt local blood-brain barrier (BBB) noninvasively via the injection of ultrasound contrast agent (UCA). In this study, we use single frequency (518kHz) ultrasound and confocal dual frequency (513kHz+523kHz) ultrasound with the injection of UCA to disrupt the local BBB. Single frequency ultrasound and dual frequency ultrasound were set at almost the same acoustic negative peak pressure, and the pulse length was 10 ms. The brain of male Wistar rats were sonicated by ultrasound with the injection of UCA. The BBB disruption was evaluated by the extravasation of Evans Blue (EB). Additionally, we try out to find the optimal ultrasound parameters without producing hemorrhage, we use single frequency ultrasound with different doses of UCA. Expect this parameter could apply on future application. There was no difference at the total extravasation amount of EB between single and dual frequency ultrasound, but the EB distribution were slightly different. Because of the short duty cycle (1%), the enhancement of cavitation effect produced by dual frequency was not obvious. In addition, the BBBD area was related to the pressure distribution. The BBBD area produced by dual frequency ultrasound was larger than single frequency ultrasound. We optimize the ultrasound parameter to 20s sonication with 10μl/kg ultrasound contrast agent dose, in this case, we could open the BBB precisely on the focal region and cause nearly no hemorrhage. When the MR enhancement was quantitatively evaluated by the EB extravasation, the correlation was very high. When it went to T1-weighted SE, the correlation coefficient between them was 0.911 (p < 0.01). When it went to T1-weighted GE, the correlation coefficient between them was 0.981 (p < 0.01). In our result, we could use MR images to take the place of EB extravasation, and we could monitor the penetration of drugs or molecules in time. 林文澧 2008 學位論文 ; thesis 62 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 醫學工程學研究所 === 96 === It has been shown that focused ultrasound (FUS) could disrupt local blood-brain barrier (BBB) noninvasively via the injection of ultrasound contrast agent (UCA). In this study, we use single frequency (518kHz) ultrasound and confocal dual frequency (513kHz+523kHz) ultrasound with the injection of UCA to disrupt the local BBB. Single frequency ultrasound and dual frequency ultrasound were set at almost the same acoustic negative peak pressure, and the pulse length was 10 ms. The brain of male Wistar rats were sonicated by ultrasound with the injection of UCA. The BBB disruption was evaluated by the extravasation of Evans Blue (EB). Additionally, we try out to find the optimal ultrasound parameters without producing hemorrhage, we use single frequency ultrasound with different doses of UCA. Expect this parameter could apply on future application. There was no difference at the total extravasation amount of EB between single and dual frequency ultrasound, but the EB distribution were slightly different. Because of the short duty cycle (1%), the enhancement of cavitation effect produced by dual frequency was not obvious. In addition, the BBBD area was related to the pressure distribution. The BBBD area produced by dual frequency ultrasound was larger than single frequency ultrasound. We optimize the ultrasound parameter to 20s sonication with 10μl/kg ultrasound contrast agent dose, in this case, we could open the BBB precisely on the focal region and cause nearly no hemorrhage. When the MR enhancement was quantitatively evaluated by the EB extravasation, the correlation was very high. When it went to T1-weighted SE, the correlation coefficient between them was 0.911 (p < 0.01). When it went to T1-weighted GE, the correlation coefficient between them was 0.981 (p < 0.01). In our result, we could use MR images to take the place of EB extravasation, and we could monitor the penetration of drugs or molecules in time.
author2 林文澧
author_facet 林文澧
Sheng-Kai Wu
吳聖凱
author Sheng-Kai Wu
吳聖凱
spellingShingle Sheng-Kai Wu
吳聖凱
Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption
author_sort Sheng-Kai Wu
title Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption
title_short Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption
title_full Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption
title_fullStr Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption
title_full_unstemmed Investigation of Single Frequency and Confocal Dual Frequency Focused Ultrasound with Contrast Agent on Local Blood-Brain Barrier Disruption
title_sort investigation of single frequency and confocal dual frequency focused ultrasound with contrast agent on local blood-brain barrier disruption
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/92131000650518674389
work_keys_str_mv AT shengkaiwu investigationofsinglefrequencyandconfocaldualfrequencyfocusedultrasoundwithcontrastagentonlocalbloodbrainbarrierdisruption
AT wúshèngkǎi investigationofsinglefrequencyandconfocaldualfrequencyfocusedultrasoundwithcontrastagentonlocalbloodbrainbarrierdisruption
AT shengkaiwu dānpínyǔgòngjiāoshuāngpínjùjiāoshìchāoyīnbōpèihéchāoyīnbōxiǎnyǐngjìyīngyòngyújúbùxuènǎopíngzhàngkāiqǐzhītàntǎo
AT wúshèngkǎi dānpínyǔgòngjiāoshuāngpínjùjiāoshìchāoyīnbōpèihéchāoyīnbōxiǎnyǐngjìyīngyòngyújúbùxuènǎopíngzhàngkāiqǐzhītàntǎo
_version_ 1718135379430735872