Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound

碩士 === 國立臺灣大學 === 資訊工程學研究所 === 96 === Several imaging modalities such as mammography, ultrasound (US), and magnetic resonance imaging (MRI) have been applied to evaluating the therapeutic response of neoadjuvant therapy for breast cancer. In this paper, the three-dimensional (3-D) Doppler US is adop...

Full description

Bibliographic Details
Main Authors: Yung-Hsiang Lei, 雷詠翔
Other Authors: Ruey-Feng Chang
Format: Others
Language:en_US
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/98661906923191756438
id ndltd-TW-096NTU05392141
record_format oai_dc
spelling ndltd-TW-096NTU053921412016-05-11T04:17:10Z http://ndltd.ncl.edu.tw/handle/98661906923191756438 Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound 利用3-D彩色超音波的乳房腫瘤化學治療反應評估 Yung-Hsiang Lei 雷詠翔 碩士 國立臺灣大學 資訊工程學研究所 96 Several imaging modalities such as mammography, ultrasound (US), and magnetic resonance imaging (MRI) have been applied to evaluating the therapeutic response of neoadjuvant therapy for breast cancer. In this paper, the three-dimensional (3-D) Doppler US is adopted for evaluating the vascularity. The conventional vascularity index (VI) method is usually used to evaluate the vascularity. From our experiments, this method could not have enough reproducibility for monitoring the chemotherapy response due to the artificial vessel noise by breath and heartbeat. Hence, a new vascularity evaluation method based on the vessel length is proposed to reduce the vessel noise in this paper. At first, the 3-D thinning algorithm for the vessel image is performed to extract the vessel skeleton and then the vessel lengths could be found from the skeleton as the vascularity. Nevertheless, this proposed vessel length information still does not have enough reproducibility due to the vessel noise. In order to improve the vessel reproducibility, a vessel noise reduction method is developed to analyze the vessel lengths. In the proposed noise reduction method, only the lengths of vessels larger than a threshold are counted. The threshold could be a fixed value or proportion to the maximum vessel radius. In the relative noise reduction method, the average reproducibilities of 20% and 10% reductions are 0.075 and 0.078 in our cases. The reproducibility of fixed threshold reduction by 5-pixel and 3-pixel are 0.119 and 0.097 respectively. The relative threshold reductions have better performance than the fixed threshold reductions. Furthermore, the response during the chemotherapy for a patient could also be evaluated by the changes of vessel lengths. The therapy evaluation result of 20% reduction is worse than that of 10% reduction. Therefore, we conclude that the 10% noise reduction method is a better evaluation method for the response of chemotherapy. Ruey-Feng Chang 張瑞峰 2008 學位論文 ; thesis 38 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 資訊工程學研究所 === 96 === Several imaging modalities such as mammography, ultrasound (US), and magnetic resonance imaging (MRI) have been applied to evaluating the therapeutic response of neoadjuvant therapy for breast cancer. In this paper, the three-dimensional (3-D) Doppler US is adopted for evaluating the vascularity. The conventional vascularity index (VI) method is usually used to evaluate the vascularity. From our experiments, this method could not have enough reproducibility for monitoring the chemotherapy response due to the artificial vessel noise by breath and heartbeat. Hence, a new vascularity evaluation method based on the vessel length is proposed to reduce the vessel noise in this paper. At first, the 3-D thinning algorithm for the vessel image is performed to extract the vessel skeleton and then the vessel lengths could be found from the skeleton as the vascularity. Nevertheless, this proposed vessel length information still does not have enough reproducibility due to the vessel noise. In order to improve the vessel reproducibility, a vessel noise reduction method is developed to analyze the vessel lengths. In the proposed noise reduction method, only the lengths of vessels larger than a threshold are counted. The threshold could be a fixed value or proportion to the maximum vessel radius. In the relative noise reduction method, the average reproducibilities of 20% and 10% reductions are 0.075 and 0.078 in our cases. The reproducibility of fixed threshold reduction by 5-pixel and 3-pixel are 0.119 and 0.097 respectively. The relative threshold reductions have better performance than the fixed threshold reductions. Furthermore, the response during the chemotherapy for a patient could also be evaluated by the changes of vessel lengths. The therapy evaluation result of 20% reduction is worse than that of 10% reduction. Therefore, we conclude that the 10% noise reduction method is a better evaluation method for the response of chemotherapy.
author2 Ruey-Feng Chang
author_facet Ruey-Feng Chang
Yung-Hsiang Lei
雷詠翔
author Yung-Hsiang Lei
雷詠翔
spellingShingle Yung-Hsiang Lei
雷詠翔
Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
author_sort Yung-Hsiang Lei
title Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
title_short Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
title_full Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
title_fullStr Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
title_full_unstemmed Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
title_sort breast cancer chemotherapy response evaluation using 3-d power doppler ultrasound
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/98661906923191756438
work_keys_str_mv AT yunghsianglei breastcancerchemotherapyresponseevaluationusing3dpowerdopplerultrasound
AT léiyǒngxiáng breastcancerchemotherapyresponseevaluationusing3dpowerdopplerultrasound
AT yunghsianglei lìyòng3dcǎisèchāoyīnbōderǔfángzhǒngliúhuàxuézhìliáofǎnyīngpínggū
AT léiyǒngxiáng lìyòng3dcǎisèchāoyīnbōderǔfángzhǒngliúhuàxuézhìliáofǎnyīngpínggū
_version_ 1718265604353294336