The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis

碩士 === 國立屏東科技大學 === 生物機電工程系所 === 96 === The research was to set up a signal measuring system, which can precede the analysis of Photoplethysmography(PPG) signal. There were two purposes for the research applying the system. First was to study the correlation between the internal concealed signal of...

Full description

Bibliographic Details
Main Authors: Wei-Chung Chen, 陳韋中
Other Authors: Hsun-Heng Tsai
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/16450581187372403017
id ndltd-TW-096NPUS5415004
record_format oai_dc
spelling ndltd-TW-096NPUS54150042016-12-22T04:12:08Z http://ndltd.ncl.edu.tw/handle/16450581187372403017 The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis 光體積變化描記器量測人體末梢血管體積變化與血管硬化之關係 Wei-Chung Chen 陳韋中 碩士 國立屏東科技大學 生物機電工程系所 96 The research was to set up a signal measuring system, which can precede the analysis of Photoplethysmography(PPG) signal. There were two purposes for the research applying the system. First was to study the correlation between the internal concealed signal of the PPG and the physiological phenomenon. Second was to study the relation between the PPG signal and the atherosclerosis. In the study, the primitive PPG signal was split to several characteristic signals through the Empirical Mode Decomposition(EMD) , then the method of the Fast Fourier Transform was applied to acquire spectrum which can find the signal relating to the heartbeat and the respiration frequency. According to the experiment result, the physiological phenomenon of respiration was successfully found from the characteristic signals which were, through EMD, transferred from the primitive PPG signal. Meanwhile, the Stiffness Index (SI) and the Reflection Index (RI) of atherosclerosis could be found by the measurement of the artery pulse signal collected by the single-finger detection. Compared to the hfPWV and the ABI which are using for the clinical diagnosis on atherosclerosis, the experiment result showed the SI strong correlating to the hfPWV by statistical factor 0.862. The study demonstrated the PPG signal measurement system had strong correlation with hfPWV which is applied for clinical diagnosis on atherosclerosis. So, the system can be for the early stage check tool to diagnose atherosclerosis. Hsun-Heng Tsai 蔡循恒 2008 學位論文 ; thesis 65 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立屏東科技大學 === 生物機電工程系所 === 96 === The research was to set up a signal measuring system, which can precede the analysis of Photoplethysmography(PPG) signal. There were two purposes for the research applying the system. First was to study the correlation between the internal concealed signal of the PPG and the physiological phenomenon. Second was to study the relation between the PPG signal and the atherosclerosis. In the study, the primitive PPG signal was split to several characteristic signals through the Empirical Mode Decomposition(EMD) , then the method of the Fast Fourier Transform was applied to acquire spectrum which can find the signal relating to the heartbeat and the respiration frequency. According to the experiment result, the physiological phenomenon of respiration was successfully found from the characteristic signals which were, through EMD, transferred from the primitive PPG signal. Meanwhile, the Stiffness Index (SI) and the Reflection Index (RI) of atherosclerosis could be found by the measurement of the artery pulse signal collected by the single-finger detection. Compared to the hfPWV and the ABI which are using for the clinical diagnosis on atherosclerosis, the experiment result showed the SI strong correlating to the hfPWV by statistical factor 0.862. The study demonstrated the PPG signal measurement system had strong correlation with hfPWV which is applied for clinical diagnosis on atherosclerosis. So, the system can be for the early stage check tool to diagnose atherosclerosis.
author2 Hsun-Heng Tsai
author_facet Hsun-Heng Tsai
Wei-Chung Chen
陳韋中
author Wei-Chung Chen
陳韋中
spellingShingle Wei-Chung Chen
陳韋中
The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis
author_sort Wei-Chung Chen
title The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis
title_short The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis
title_full The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis
title_fullStr The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis
title_full_unstemmed The Relationship between Peripheral Artery Volume Change Detected by Photoplethysmography and Atherosclerosis
title_sort relationship between peripheral artery volume change detected by photoplethysmography and atherosclerosis
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/16450581187372403017
work_keys_str_mv AT weichungchen therelationshipbetweenperipheralarteryvolumechangedetectedbyphotoplethysmographyandatherosclerosis
AT chénwéizhōng therelationshipbetweenperipheralarteryvolumechangedetectedbyphotoplethysmographyandatherosclerosis
AT weichungchen guāngtǐjībiànhuàmiáojìqìliàngcèréntǐmòshāoxuèguǎntǐjībiànhuàyǔxuèguǎnyìnghuàzhīguānxì
AT chénwéizhōng guāngtǐjībiànhuàmiáojìqìliàngcèréntǐmòshāoxuèguǎntǐjībiànhuàyǔxuèguǎnyìnghuàzhīguānxì
AT weichungchen relationshipbetweenperipheralarteryvolumechangedetectedbyphotoplethysmographyandatherosclerosis
AT chénwéizhōng relationshipbetweenperipheralarteryvolumechangedetectedbyphotoplethysmographyandatherosclerosis
_version_ 1718403306033774592