A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system
碩士 === 國立暨南國際大學 === 生物醫學科技研究所 === 96 === This thesis presents a multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system. It is an all-in-one therapeutic instrument. It includes LCD component, switch circuit and constant current driving circuit....
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2008
|
Online Access: | http://ndltd.ncl.edu.tw/handle/40125179523995416982 |
id |
ndltd-TW-096NCNU0114003 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-096NCNU01140032015-10-13T13:47:50Z http://ndltd.ncl.edu.tw/handle/40125179523995416982 A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system 多功能具迴授控制驅動電路設計應用於光療與電療治療儀系統 Yuan Ho 賀淵 碩士 國立暨南國際大學 生物醫學科技研究所 96 This thesis presents a multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system. It is an all-in-one therapeutic instrument. It includes LCD component, switch circuit and constant current driving circuit. It has been designed by PIC to make up a multi-functional therapy system with light and electrical stimulation for medical application. This text will recommend the treatment of the light and electrical stimulation( micro current electrical stimulation ) to develop at first and overall system structure and theory secondly. Then, we have explained the sub circuit in the system structure, for instance: the driving circuit design and how to reject the offset voltage of op Amp. The phototherapy which is red, blue and green light has different power (under the frequency= 100Hz, duty cycle= 6% and current= 100mA) 12.34mW/cm2, 11.92 mW/cm2, 7 mW/cm2. separately. In this condition(frequency= 100Hz, duty cycle= 6% and current= 100mA ), we can find the better efficiency. After calculation, it can reach the record in the other paper. Micro-current electrical stimulation works at different constant current under frequency= 100Hz and we can find the better linearity at various loading resistance. Tai-Ping Sun 孫台平 2008 學位論文 ; thesis 67 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立暨南國際大學 === 生物醫學科技研究所 === 96 === This thesis presents a multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system. It is an all-in-one therapeutic instrument. It includes LCD component, switch circuit and constant current driving circuit. It has been designed by PIC to make up a multi-functional therapy system with light and electrical stimulation for medical application. This text will recommend the treatment of the light and electrical stimulation( micro current electrical stimulation ) to develop at first and overall system structure and theory secondly. Then, we have explained the sub circuit in the system structure, for instance: the driving circuit design and how to reject the offset voltage of op Amp. The phototherapy which is red, blue and green light has different power (under the frequency= 100Hz, duty cycle= 6% and current= 100mA) 12.34mW/cm2, 11.92 mW/cm2, 7 mW/cm2. separately. In this condition(frequency= 100Hz, duty cycle= 6% and current= 100mA ), we can find the better efficiency. After calculation, it can reach the record in the other paper. Micro-current electrical stimulation works at different constant current under frequency= 100Hz and we can find the better linearity at various loading resistance.
|
author2 |
Tai-Ping Sun |
author_facet |
Tai-Ping Sun Yuan Ho 賀淵 |
author |
Yuan Ho 賀淵 |
spellingShingle |
Yuan Ho 賀淵 A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
author_sort |
Yuan Ho |
title |
A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
title_short |
A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
title_full |
A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
title_fullStr |
A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
title_full_unstemmed |
A multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
title_sort |
multi-function driving circuit design with feedback control for phototherapy and electrical stimulation system |
publishDate |
2008 |
url |
http://ndltd.ncl.edu.tw/handle/40125179523995416982 |
work_keys_str_mv |
AT yuanho amultifunctiondrivingcircuitdesignwithfeedbackcontrolforphototherapyandelectricalstimulationsystem AT hèyuān amultifunctiondrivingcircuitdesignwithfeedbackcontrolforphototherapyandelectricalstimulationsystem AT yuanho duōgōngnéngjùhuíshòukòngzhìqūdòngdiànlùshèjìyīngyòngyúguāngliáoyǔdiànliáozhìliáoyíxìtǒng AT hèyuān duōgōngnéngjùhuíshòukòngzhìqūdòngdiànlùshèjìyīngyòngyúguāngliáoyǔdiànliáozhìliáoyíxìtǒng AT yuanho multifunctiondrivingcircuitdesignwithfeedbackcontrolforphototherapyandelectricalstimulationsystem AT hèyuān multifunctiondrivingcircuitdesignwithfeedbackcontrolforphototherapyandelectricalstimulationsystem |
_version_ |
1717742605789298688 |