The effect of camber on shoulder muscle force in wheelchair propulsion
碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 96 === Wheelchair is the most common device for individuals with spinal cord injury. It is very easy to make the upper extremity get hurt especially shoulder joint when long term using. The camber of the rear wheel is a common characteristic in sports wheelchair, an...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2008
|
Online Access: | http://ndltd.ncl.edu.tw/handle/83630984329624981704 |
id |
ndltd-TW-096NCKU5530032 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-096NCKU55300322015-11-23T04:03:10Z http://ndltd.ncl.edu.tw/handle/83630984329624981704 The effect of camber on shoulder muscle force in wheelchair propulsion 輪椅後輪傾角對肩關節的肌肉力學影響 Chao-Sian Shih 施超獻 碩士 國立成功大學 醫學工程研究所碩博士班 96 Wheelchair is the most common device for individuals with spinal cord injury. It is very easy to make the upper extremity get hurt especially shoulder joint when long term using. The camber of the rear wheel is a common characteristic in sports wheelchair, and it is an important factor in wheelchair propulsion. However, the effect of camber on muscle forces of upper extremities hasn’t been studied in previous studies. The object of this research is to exam the effects of camber on shoulder muscle forces using simulation method to analysis the muscle force in different kinds of camber angle. Twelve healthy subjects, who are unexperience wheelchair users, participated in this study. We use motion capture system to collect the kinematics data. An instrumented wheel with load cell was used to collect the force data. A previously built three dimensional shoulder musculoskeletal model was to calculate muscle forces of thirteen muscles around shoulder joint. In this research, participants were asked to propel wheelchair with 0˚, 9˚, and 15˚ rear wheel camber. Control the average wheelchair propulsion speed in 1m/s and 2m/s. The results indicated that when the speed increase, the activation of the muscle groups activating during propulsion phase increase and maximum muscle force also became larger. Muscle activation pattern did not change with different camber angle. Anterior deltoid had greater muscle force when we increase camber angle. The other usually have minimum in 9˚ or have no significant difference. By the research, we also can provide some information to the wheelchair user and designer. Help them to find some optimal balance between the wheelchair resistance and fraction of effective force. Fong-Chin Su 蘇芳慶 2008 學位論文 ; thesis 64 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 96 === Wheelchair is the most common device for individuals with spinal cord injury. It is very easy to make the upper extremity get hurt especially shoulder joint when long term using. The camber of the rear wheel is a common characteristic in sports wheelchair, and it is an important factor in wheelchair propulsion. However, the effect of camber on muscle forces of upper extremities hasn’t been studied in previous studies. The object of this research is to exam the effects of camber on shoulder muscle forces using simulation method to analysis the muscle force in different kinds of camber angle.
Twelve healthy subjects, who are unexperience wheelchair users, participated in this study. We use motion capture system to collect the kinematics data. An instrumented wheel with load cell was used to collect the force data. A previously built three dimensional shoulder musculoskeletal model was to calculate muscle forces of thirteen muscles around shoulder joint. In this research, participants were asked to propel wheelchair with 0˚, 9˚, and 15˚ rear wheel camber. Control the average wheelchair propulsion speed in 1m/s and 2m/s.
The results indicated that when the speed increase, the activation of the muscle groups activating during propulsion phase increase and maximum muscle force also became larger. Muscle activation pattern did not change with different camber angle. Anterior deltoid had greater muscle force when we increase camber angle. The other usually have minimum in 9˚ or have no significant difference. By the research, we also can provide some information to the wheelchair user and designer. Help them to find some optimal balance between the wheelchair resistance and fraction of effective force.
|
author2 |
Fong-Chin Su |
author_facet |
Fong-Chin Su Chao-Sian Shih 施超獻 |
author |
Chao-Sian Shih 施超獻 |
spellingShingle |
Chao-Sian Shih 施超獻 The effect of camber on shoulder muscle force in wheelchair propulsion |
author_sort |
Chao-Sian Shih |
title |
The effect of camber on shoulder muscle force in wheelchair propulsion |
title_short |
The effect of camber on shoulder muscle force in wheelchair propulsion |
title_full |
The effect of camber on shoulder muscle force in wheelchair propulsion |
title_fullStr |
The effect of camber on shoulder muscle force in wheelchair propulsion |
title_full_unstemmed |
The effect of camber on shoulder muscle force in wheelchair propulsion |
title_sort |
effect of camber on shoulder muscle force in wheelchair propulsion |
publishDate |
2008 |
url |
http://ndltd.ncl.edu.tw/handle/83630984329624981704 |
work_keys_str_mv |
AT chaosianshih theeffectofcamberonshouldermuscleforceinwheelchairpropulsion AT shīchāoxiàn theeffectofcamberonshouldermuscleforceinwheelchairpropulsion AT chaosianshih lúnyǐhòulúnqīngjiǎoduìjiānguānjiédejīròulìxuéyǐngxiǎng AT shīchāoxiàn lúnyǐhòulúnqīngjiǎoduìjiānguānjiédejīròulìxuéyǐngxiǎng AT chaosianshih effectofcamberonshouldermuscleforceinwheelchairpropulsion AT shīchāoxiàn effectofcamberonshouldermuscleforceinwheelchairpropulsion |
_version_ |
1718134171456503808 |