Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems

碩士 === 國立高雄應用科技大學 === 土木工程與防災科技研究所 === 98 === Recently the aseismic performance of buildings and theories and techniques of earthquake isolation are continuously developed. The thesis is proposed to investigate the dynamic responses of buildings using various isolation approaches, including base iso...

Full description

Bibliographic Details
Main Authors: Yang, Jia-Ru, 楊佳儒
Other Authors: Huang, Li-Jeng
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/06761908312986925323
id ndltd-TW-096KUAS0653029
record_format oai_dc
spelling ndltd-TW-096KUAS06530292016-12-05T04:05:15Z http://ndltd.ncl.edu.tw/handle/06761908312986925323 Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems 樓房採用基礎與層間複合隔震系統之振動抑制 Yang, Jia-Ru 楊佳儒 碩士 國立高雄應用科技大學 土木工程與防災科技研究所 98 Recently the aseismic performance of buildings and theories and techniques of earthquake isolation are continuously developed. The thesis is proposed to investigate the dynamic responses of buildings using various isolation approaches, including base isolation, mid-story isolation, multi-stories isolation, etc., under various external loadings. Lumped mass model is employed for simulating the dynamic model of buildings without and with isolation designs wherein horizontal displacement of each story is chosen to be the degree of freedom. Lead Rubber Bearing (LRB) is adopted to be the isolator. Various types of eternal loads are considered, such as free vibration, unit step excitation, harmonic forcing and ground motions. A simplified theoretical model is first employed to depict the fundamental behavior of isolator embedded at base and top-story. It is found that as the mass of top-story isolator is very smaller its behavior is similar to a tuned mass damper (TMD). Then dynamic equations of 8 cases of different layouts of non-isolated and isolated are derived, respectively, and then transformed into state-space descriptions and then Runge-Kutta method is used to calculate the time-domain dynamic responses. Numerical experiments show that the all-stories isolation and base-mid-story isolation systems are better than classical base isolation and mid-story single isolation systems in the inter-story displacements and inter-story accelerations of the floors. Parametric study leads to the fact that adjustment of the mass, damping and stiffness parameters of isolators would cause significant influence of dynamic response of the systems. Mass effect is relatively smaller, damping constants are effectively in reducing the displacements, while frequency ratio =2 is the best choice in the current case. Huang, Li-Jeng 黃立政 2009 學位論文 ; thesis 0 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄應用科技大學 === 土木工程與防災科技研究所 === 98 === Recently the aseismic performance of buildings and theories and techniques of earthquake isolation are continuously developed. The thesis is proposed to investigate the dynamic responses of buildings using various isolation approaches, including base isolation, mid-story isolation, multi-stories isolation, etc., under various external loadings. Lumped mass model is employed for simulating the dynamic model of buildings without and with isolation designs wherein horizontal displacement of each story is chosen to be the degree of freedom. Lead Rubber Bearing (LRB) is adopted to be the isolator. Various types of eternal loads are considered, such as free vibration, unit step excitation, harmonic forcing and ground motions. A simplified theoretical model is first employed to depict the fundamental behavior of isolator embedded at base and top-story. It is found that as the mass of top-story isolator is very smaller its behavior is similar to a tuned mass damper (TMD). Then dynamic equations of 8 cases of different layouts of non-isolated and isolated are derived, respectively, and then transformed into state-space descriptions and then Runge-Kutta method is used to calculate the time-domain dynamic responses. Numerical experiments show that the all-stories isolation and base-mid-story isolation systems are better than classical base isolation and mid-story single isolation systems in the inter-story displacements and inter-story accelerations of the floors. Parametric study leads to the fact that adjustment of the mass, damping and stiffness parameters of isolators would cause significant influence of dynamic response of the systems. Mass effect is relatively smaller, damping constants are effectively in reducing the displacements, while frequency ratio =2 is the best choice in the current case.
author2 Huang, Li-Jeng
author_facet Huang, Li-Jeng
Yang, Jia-Ru
楊佳儒
author Yang, Jia-Ru
楊佳儒
spellingShingle Yang, Jia-Ru
楊佳儒
Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems
author_sort Yang, Jia-Ru
title Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems
title_short Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems
title_full Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems
title_fullStr Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems
title_full_unstemmed Vibration Reduction of Building Using Base and Mid-Story Hybrid Isolated Systems
title_sort vibration reduction of building using base and mid-story hybrid isolated systems
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/06761908312986925323
work_keys_str_mv AT yangjiaru vibrationreductionofbuildingusingbaseandmidstoryhybridisolatedsystems
AT yángjiārú vibrationreductionofbuildingusingbaseandmidstoryhybridisolatedsystems
AT yangjiaru lóufángcǎiyòngjīchǔyǔcéngjiānfùhégézhènxìtǒngzhīzhèndòngyìzhì
AT yángjiārú lóufángcǎiyòngjīchǔyǔcéngjiānfùhégézhènxìtǒngzhīzhèndòngyìzhì
_version_ 1718398641207508992