Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms

碩士 === 輔仁大學 === 公共衛生學系碩士班 === 96 === Abstract Introduction: Electrocautery is widely used to cut and coagulate tissue during surgery in the operating room. A visible smoke with unpleasant odor is produced by electrocautery to pyrolysis tissue. It’s so-called “electrocautery smoke”. Electrocautery s...

Full description

Bibliographic Details
Main Authors: Kuo-Hui Chang, 張國輝
Other Authors: Chin-Sheng Tang
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/7c3wmk
id ndltd-TW-096FJU00058001
record_format oai_dc
spelling ndltd-TW-096FJU000580012019-05-15T20:22:22Z http://ndltd.ncl.edu.tw/handle/7c3wmk Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms 手術室中電刀煙霧之特定化學物質調查 Kuo-Hui Chang 張國輝 碩士 輔仁大學 公共衛生學系碩士班 96 Abstract Introduction: Electrocautery is widely used to cut and coagulate tissue during surgery in the operating room. A visible smoke with unpleasant odor is produced by electrocautery to pyrolysis tissue. It’s so-called “electrocautery smoke”. Electrocautery smoke contains several mutagens and carcinogens. This study intends to quantify certain chemicals with unpleasant odor and hazard in the electrocautery smoke. Meanwhile, the correlation between the concentrations and the factors included the type of diagnosis, surgery, patient’s BMI, suction condition, using electrocautery time and energy will be analyzed. Method: This study was conducted in a medical center hospital of Taipei and focused on the breast surgeries. The investigated chemicals included toluene, styrene, o,m- xylenes, phenol, acrolein and furfural. The electrocautery smoke was collected by different samplers to investigate the concentrations of target chemicals simultaneously. The samplers were SKC 575-002 passive sampler for toluene, styrene and xylenes; SKC active samplers: ST 226-95 (XAD-7), ST 226-118 (XAD-2), SKC 226-01 (charcoal) for phenol, acrolein and furfural respectively. All samplers were assembled in a chamber system and the sampling probe was located at approximately 2 ~ 3 cm from the tip of diathermy pencil. Gas Chromatography-Mass Spectrometer (GC-MS) was utilized for qualification and quantitation purposes. For each sample, the personal (patient) data, surgery, suction, using electrocautery time and energy were recorded for further analyzed. Result: Five individual samples and five cumulated samples were collected. The concentrations of styrene, o,m-xylenes, phenol, acrolein and furfural were lower than lowest quantitation levels(LQLs)in all samples. Toluene was identified in nine samples. The toluene concentration ranges of individual samples were 2.48 mg/m3 ~ 5.50 mg/m3(0.65 ppm ~ 1.45 ppm)and cumulated samples were 1.80 mg/m3 ~ 22.00 mg/m3(0.47 ppm ~ 5.80 ppm). All measured concentrations of toluene are lowered than the 2006 ACGIH TLV-TWA, 50 ppm. Conclusion: No correlation between the chemical concentrations and the type of diagnosis, suction system, using electrocautery time and energy were established in this study. However, the patient’s BMI and type of surgery might affect the toluene concentrations. More research on odor materials of electrocautery smoke should be performed. Keyword: electrocautery smoke, toluene, styrene, o,m-xylenes, phenol, acrolein, furfural, GC-MS. Chin-Sheng Tang 唐進勝 2007 學位論文 ; thesis 90 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 輔仁大學 === 公共衛生學系碩士班 === 96 === Abstract Introduction: Electrocautery is widely used to cut and coagulate tissue during surgery in the operating room. A visible smoke with unpleasant odor is produced by electrocautery to pyrolysis tissue. It’s so-called “electrocautery smoke”. Electrocautery smoke contains several mutagens and carcinogens. This study intends to quantify certain chemicals with unpleasant odor and hazard in the electrocautery smoke. Meanwhile, the correlation between the concentrations and the factors included the type of diagnosis, surgery, patient’s BMI, suction condition, using electrocautery time and energy will be analyzed. Method: This study was conducted in a medical center hospital of Taipei and focused on the breast surgeries. The investigated chemicals included toluene, styrene, o,m- xylenes, phenol, acrolein and furfural. The electrocautery smoke was collected by different samplers to investigate the concentrations of target chemicals simultaneously. The samplers were SKC 575-002 passive sampler for toluene, styrene and xylenes; SKC active samplers: ST 226-95 (XAD-7), ST 226-118 (XAD-2), SKC 226-01 (charcoal) for phenol, acrolein and furfural respectively. All samplers were assembled in a chamber system and the sampling probe was located at approximately 2 ~ 3 cm from the tip of diathermy pencil. Gas Chromatography-Mass Spectrometer (GC-MS) was utilized for qualification and quantitation purposes. For each sample, the personal (patient) data, surgery, suction, using electrocautery time and energy were recorded for further analyzed. Result: Five individual samples and five cumulated samples were collected. The concentrations of styrene, o,m-xylenes, phenol, acrolein and furfural were lower than lowest quantitation levels(LQLs)in all samples. Toluene was identified in nine samples. The toluene concentration ranges of individual samples were 2.48 mg/m3 ~ 5.50 mg/m3(0.65 ppm ~ 1.45 ppm)and cumulated samples were 1.80 mg/m3 ~ 22.00 mg/m3(0.47 ppm ~ 5.80 ppm). All measured concentrations of toluene are lowered than the 2006 ACGIH TLV-TWA, 50 ppm. Conclusion: No correlation between the chemical concentrations and the type of diagnosis, suction system, using electrocautery time and energy were established in this study. However, the patient’s BMI and type of surgery might affect the toluene concentrations. More research on odor materials of electrocautery smoke should be performed. Keyword: electrocautery smoke, toluene, styrene, o,m-xylenes, phenol, acrolein, furfural, GC-MS.
author2 Chin-Sheng Tang
author_facet Chin-Sheng Tang
Kuo-Hui Chang
張國輝
author Kuo-Hui Chang
張國輝
spellingShingle Kuo-Hui Chang
張國輝
Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms
author_sort Kuo-Hui Chang
title Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms
title_short Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms
title_full Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms
title_fullStr Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms
title_full_unstemmed Investigate the Certain Toxic Chemicals of Electrocautery Smoke in Operation Rooms
title_sort investigate the certain toxic chemicals of electrocautery smoke in operation rooms
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/7c3wmk
work_keys_str_mv AT kuohuichang investigatethecertaintoxicchemicalsofelectrocauterysmokeinoperationrooms
AT zhāngguóhuī investigatethecertaintoxicchemicalsofelectrocauterysmokeinoperationrooms
AT kuohuichang shǒushùshìzhōngdiàndāoyānwùzhītèdìnghuàxuéwùzhìdiàochá
AT zhāngguóhuī shǒushùshìzhōngdiàndāoyānwùzhītèdìnghuàxuéwùzhìdiàochá
_version_ 1719099122039914496