The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter
碩士 === 清雲科技大學 === 電機工程研究所 === 96 === Generally,the traditional three-phase three-leg DC-to-AC power inverter are used widely with three phase balanced loads. But, when the three-phase loads are unbalanced, that three phase voltage outputs can not be symmetrical. In this paper presents a three-phase...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2008
|
Online Access: | http://ndltd.ncl.edu.tw/handle/38861606677135525723 |
id |
ndltd-TW-096CYU00442015 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-096CYU004420152015-11-30T04:02:17Z http://ndltd.ncl.edu.tw/handle/38861606677135525723 The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter 三相四臂式直流-交流功率轉換器之控制與實現 Wei-You Sun 孫瑋佑 碩士 清雲科技大學 電機工程研究所 96 Generally,the traditional three-phase three-leg DC-to-AC power inverter are used widely with three phase balanced loads. But, when the three-phase loads are unbalanced, that three phase voltage outputs can not be symmetrical. In this paper presents a three-phase four-leg DC-to-AC power inverter can be supply a midpoint to three phase unbalanced loads.So the three-phase four-leg DC-to-AC power inverter outputs three phase symmetrical voltages. Using symmetrical model analysises three-phase four-leg DC-to-AC power inverter how it suppresses the unbalanced loads. The mathematic model of three-phase four-leg DC-to-AC power inverter is established in different coordinates. Paper accomplishes the decoupling of the three-phase four-leg DC-to-AC power inverter. PI double loop controller based on synchronous frame is applied. The control circuit cosists of digital processor(DSP TMS320F2808PZA),which programmed in C language. The performance of system is simulated MATLAB SIMULINK. Experiments the three-phase four-leg DC-to-AC power inverter can output three-phase balanced AC voltage under the unbalanced loads conditions. Yin-Chin Wu 吳英秦 2008 學位論文 ; thesis 55 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 清雲科技大學 === 電機工程研究所 === 96 === Generally,the traditional three-phase three-leg DC-to-AC power inverter are used widely with three phase balanced loads. But, when the three-phase loads are unbalanced, that
three phase voltage outputs can not be symmetrical. In this paper presents a three-phase four-leg DC-to-AC power inverter can be supply a midpoint to three phase unbalanced loads.So the three-phase four-leg DC-to-AC power inverter outputs three phase symmetrical
voltages.
Using symmetrical model analysises three-phase four-leg DC-to-AC power inverter how it suppresses the unbalanced loads. The mathematic model of three-phase four-leg DC-to-AC power inverter is established in different coordinates. Paper accomplishes the
decoupling of the three-phase four-leg DC-to-AC power inverter. PI double loop controller based on synchronous frame is applied.
The control circuit cosists of digital processor(DSP TMS320F2808PZA),which programmed in C language. The performance of system is simulated MATLAB SIMULINK. Experiments the three-phase four-leg DC-to-AC power inverter can output three-phase balanced AC voltage under the unbalanced loads conditions.
|
author2 |
Yin-Chin Wu |
author_facet |
Yin-Chin Wu Wei-You Sun 孫瑋佑 |
author |
Wei-You Sun 孫瑋佑 |
spellingShingle |
Wei-You Sun 孫瑋佑 The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter |
author_sort |
Wei-You Sun |
title |
The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter |
title_short |
The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter |
title_full |
The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter |
title_fullStr |
The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter |
title_full_unstemmed |
The Control and Implementation of Three-Phase Four-Leg DC-to-AC Power Inverter |
title_sort |
control and implementation of three-phase four-leg dc-to-ac power inverter |
publishDate |
2008 |
url |
http://ndltd.ncl.edu.tw/handle/38861606677135525723 |
work_keys_str_mv |
AT weiyousun thecontrolandimplementationofthreephasefourlegdctoacpowerinverter AT sūnwěiyòu thecontrolandimplementationofthreephasefourlegdctoacpowerinverter AT weiyousun sānxiāngsìbìshìzhíliújiāoliúgōnglǜzhuǎnhuànqìzhīkòngzhìyǔshíxiàn AT sūnwěiyòu sānxiāngsìbìshìzhíliújiāoliúgōnglǜzhuǎnhuànqìzhīkòngzhìyǔshíxiàn AT weiyousun controlandimplementationofthreephasefourlegdctoacpowerinverter AT sūnwěiyòu controlandimplementationofthreephasefourlegdctoacpowerinverter |
_version_ |
1718138909391585280 |