Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line

碩士 === 國立臺灣科技大學 === 電機工程系 === 95 === In Taiwan, the main protection scheme of transmission lines include current differential relay, distance relay and pilot wire relay. The backup protection scheme of transmission lines include three zone distance relay and directional overcurrent relay. Among them...

Full description

Bibliographic Details
Main Authors: Yu-liang Lin, 林裕梁
Other Authors: Jyh-Cherng Gu
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/vzuz4e
id ndltd-TW-095NTUS5442079
record_format oai_dc
spelling ndltd-TW-095NTUS54420792019-05-15T19:48:56Z http://ndltd.ncl.edu.tw/handle/vzuz4e Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line 輸電線Zone-2測距保護之電腦輔助計算與標置 Yu-liang Lin 林裕梁 碩士 國立臺灣科技大學 電機工程系 95 In Taiwan, the main protection scheme of transmission lines include current differential relay, distance relay and pilot wire relay. The backup protection scheme of transmission lines include three zone distance relay and directional overcurrent relay. Among them, the settings of the backup protective relays need to be coordinated. According to the principle of the distance relay settings at present, this paper plans to use the relay settings coordination theory, the network admittance matrix abbreviation and the fault current distribution calculation trying to develop the windowlizing calculating program of distance relay settings. Then using ASPEN software to simulate directional overcurrent relay settings to achieve the coordination between distance relays and directional overcurrent relays of the transmission line. This paper hopes to evaluate the coordination situation of the domestic transmission lines by computer procedure immediately and pinpoint the problems. Then studying the way to improve and providing more suitable approach of the Zone-2 setting of the distance relay. The results of the systematic simulation have been observed, up till now, that the influences of the apparent impedance caused by the infeed and outfeed effects can't be ignored, because the distributed generations are increasing. Or it will cause distance relays to make misjudgment whether the fault point is within the protection zone. this paper further considers the situation in case of one transmission line outage (N-1). The new Zone-2 setting can be used in more extensive power system structure and needn’t change the settings when one transmission line outage temporary. From the results of this paper, the promotion of the Zone-2 protection zone also be observed. So that the approach can be the reference when revising the principle of the distance relay settings at present. Jyh-Cherng Gu 辜志承 2007 學位論文 ; thesis 88 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 95 === In Taiwan, the main protection scheme of transmission lines include current differential relay, distance relay and pilot wire relay. The backup protection scheme of transmission lines include three zone distance relay and directional overcurrent relay. Among them, the settings of the backup protective relays need to be coordinated. According to the principle of the distance relay settings at present, this paper plans to use the relay settings coordination theory, the network admittance matrix abbreviation and the fault current distribution calculation trying to develop the windowlizing calculating program of distance relay settings. Then using ASPEN software to simulate directional overcurrent relay settings to achieve the coordination between distance relays and directional overcurrent relays of the transmission line. This paper hopes to evaluate the coordination situation of the domestic transmission lines by computer procedure immediately and pinpoint the problems. Then studying the way to improve and providing more suitable approach of the Zone-2 setting of the distance relay. The results of the systematic simulation have been observed, up till now, that the influences of the apparent impedance caused by the infeed and outfeed effects can't be ignored, because the distributed generations are increasing. Or it will cause distance relays to make misjudgment whether the fault point is within the protection zone. this paper further considers the situation in case of one transmission line outage (N-1). The new Zone-2 setting can be used in more extensive power system structure and needn’t change the settings when one transmission line outage temporary. From the results of this paper, the promotion of the Zone-2 protection zone also be observed. So that the approach can be the reference when revising the principle of the distance relay settings at present.
author2 Jyh-Cherng Gu
author_facet Jyh-Cherng Gu
Yu-liang Lin
林裕梁
author Yu-liang Lin
林裕梁
spellingShingle Yu-liang Lin
林裕梁
Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line
author_sort Yu-liang Lin
title Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line
title_short Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line
title_full Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line
title_fullStr Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line
title_full_unstemmed Computer-Aided Calculation and Setting for Zone-2 Distance Relay Protection of Transmission Line
title_sort computer-aided calculation and setting for zone-2 distance relay protection of transmission line
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/vzuz4e
work_keys_str_mv AT yulianglin computeraidedcalculationandsettingforzone2distancerelayprotectionoftransmissionline
AT línyùliáng computeraidedcalculationandsettingforzone2distancerelayprotectionoftransmissionline
AT yulianglin shūdiànxiànzone2cèjùbǎohùzhīdiànnǎofǔzhùjìsuànyǔbiāozhì
AT línyùliáng shūdiànxiànzone2cèjùbǎohùzhīdiànnǎofǔzhùjìsuànyǔbiāozhì
_version_ 1719095547838595072