Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing

碩士 === 國立臺灣科技大學 === 電機工程系 === 95 === Issues related to generation of tissue harmonic signal are discussed in this study. Tissue harmonic signal is produced due to finite amplitude distortion when sound wave propagates through the body. Intensity of tissue harmonic is generally low and thus the sensi...

Full description

Bibliographic Details
Main Authors: Yu-Jung Wang, 王裕鈞
Other Authors: Che-Chou Shen
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/3cy6nt
id ndltd-TW-095NTUS5442071
record_format oai_dc
spelling ndltd-TW-095NTUS54420712019-05-15T19:48:56Z http://ndltd.ncl.edu.tw/handle/3cy6nt Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing 使用三倍頻發射相位法於組織諧波信號分析 Yu-Jung Wang 王裕鈞 碩士 國立臺灣科技大學 電機工程系 95 Issues related to generation of tissue harmonic signal are discussed in this study. Tissue harmonic signal is produced due to finite amplitude distortion when sound wave propagates through the body. Intensity of tissue harmonic is generally low and thus the sensitivity and penetration in tissue harmonic imaging is limited. In contrast harmonic imaging, however, suppression of tissue harmonic is beneficial because tissue harmonic may reduce image contrast between contrast agents and surrounding tissues. In the study we propose a new approach, third harmonic transmit phasing , which is based on phasing the frequency-sum and frequency-difference components of tissue harmonic signal to enhance or to suppress tissue harmonic signal. The proposed method doesn’t decrease contrast resolution when the tissue harmonic is enhanced. Though suppression of tissue harmonic is achieved at the cost of elevated sidelobes, improvement of image contrast in contrast harmonic imaging is not affected. Che-Chou Shen 沈哲州 2007 學位論文 ; thesis 75 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 95 === Issues related to generation of tissue harmonic signal are discussed in this study. Tissue harmonic signal is produced due to finite amplitude distortion when sound wave propagates through the body. Intensity of tissue harmonic is generally low and thus the sensitivity and penetration in tissue harmonic imaging is limited. In contrast harmonic imaging, however, suppression of tissue harmonic is beneficial because tissue harmonic may reduce image contrast between contrast agents and surrounding tissues. In the study we propose a new approach, third harmonic transmit phasing , which is based on phasing the frequency-sum and frequency-difference components of tissue harmonic signal to enhance or to suppress tissue harmonic signal. The proposed method doesn’t decrease contrast resolution when the tissue harmonic is enhanced. Though suppression of tissue harmonic is achieved at the cost of elevated sidelobes, improvement of image contrast in contrast harmonic imaging is not affected.
author2 Che-Chou Shen
author_facet Che-Chou Shen
Yu-Jung Wang
王裕鈞
author Yu-Jung Wang
王裕鈞
spellingShingle Yu-Jung Wang
王裕鈞
Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing
author_sort Yu-Jung Wang
title Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing
title_short Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing
title_full Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing
title_fullStr Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing
title_full_unstemmed Analysis of Tissue Harmonic Signal based on Third Harmonic Transmit Phasing
title_sort analysis of tissue harmonic signal based on third harmonic transmit phasing
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/3cy6nt
work_keys_str_mv AT yujungwang analysisoftissueharmonicsignalbasedonthirdharmonictransmitphasing
AT wángyùjūn analysisoftissueharmonicsignalbasedonthirdharmonictransmitphasing
AT yujungwang shǐyòngsānbèipínfāshèxiāngwèifǎyúzǔzhīxiébōxìnhàofēnxī
AT wángyùjūn shǐyòngsānbèipínfāshèxiāngwèifǎyúzǔzhīxiébōxìnhàofēnxī
_version_ 1719095543704059904