Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device

碩士 === 國立臺灣科技大學 === 工業管理系 === 95 === Followed the concepts of using natural postures in the operations of a finger-operated pointing input device (FPD) that was developed earlier in this laboratory, the study redesigned and verified the performance and muscle loading on the hand. Two experiments wer...

Full description

Bibliographic Details
Main Authors: Yi-Cherng Su, 蘇怡誠
Other Authors: Yung-Hui Lee
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/mqy5r2
id ndltd-TW-095NTUS5041019
record_format oai_dc
spelling ndltd-TW-095NTUS50410192019-05-15T19:48:42Z http://ndltd.ncl.edu.tw/handle/mqy5r2 Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device 指控點選輸入裝置之改善設計與使用肌群疲勞測試 Yi-Cherng Su 蘇怡誠 碩士 國立臺灣科技大學 工業管理系 95 Followed the concepts of using natural postures in the operations of a finger-operated pointing input device (FPD) that was developed earlier in this laboratory, the study redesigned and verified the performance and muscle loading on the hand. Two experiments were conducted and nineteen subjects were recruited for the studies. Fitts’ law tests were used for performance comparisons in the first experiment. Operational efficiencies were normalized according to the efficiency of using MICROSOFT mouse. The result showed that the pointing and dragging operational efficiency of FPD was 45.73% and 39.32% of that of the mouse, respectively. They were improvements when compared with that of the previously developed FPD. Comparisons of muscle loading on hand, using Logitech TrackMan and FPD, while playing Microsoft computer game “solitaire,” was conduced in the second experiment. The result showed that the number of times that fatigue occurred at Abductor pollicis longus using FPD was 10%, and was 40% for Opponens pollicis 40%. When using Logitech TrackMan Whell, they were 60% and 70%, respectively. On the contrary, fatigue occurred at the Adductor pollicis for 70% of FPD users’ and there were 10% while using Logitech TrackMan Whell. Subjectively comparing showed that whole appraisal for FPD is of the same level as that of the Logitech TrackMan Whell. We attributed manly to the unfamiliarity of the users for lower performance and higher loading on the hand while using FPD. Improvement of pointing feedback and increase exercise time were suggested for the improvement of task performance. Yung-Hui Lee 李永輝 2007 學位論文 ; thesis 112 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 工業管理系 === 95 === Followed the concepts of using natural postures in the operations of a finger-operated pointing input device (FPD) that was developed earlier in this laboratory, the study redesigned and verified the performance and muscle loading on the hand. Two experiments were conducted and nineteen subjects were recruited for the studies. Fitts’ law tests were used for performance comparisons in the first experiment. Operational efficiencies were normalized according to the efficiency of using MICROSOFT mouse. The result showed that the pointing and dragging operational efficiency of FPD was 45.73% and 39.32% of that of the mouse, respectively. They were improvements when compared with that of the previously developed FPD. Comparisons of muscle loading on hand, using Logitech TrackMan and FPD, while playing Microsoft computer game “solitaire,” was conduced in the second experiment. The result showed that the number of times that fatigue occurred at Abductor pollicis longus using FPD was 10%, and was 40% for Opponens pollicis 40%. When using Logitech TrackMan Whell, they were 60% and 70%, respectively. On the contrary, fatigue occurred at the Adductor pollicis for 70% of FPD users’ and there were 10% while using Logitech TrackMan Whell. Subjectively comparing showed that whole appraisal for FPD is of the same level as that of the Logitech TrackMan Whell. We attributed manly to the unfamiliarity of the users for lower performance and higher loading on the hand while using FPD. Improvement of pointing feedback and increase exercise time were suggested for the improvement of task performance.
author2 Yung-Hui Lee
author_facet Yung-Hui Lee
Yi-Cherng Su
蘇怡誠
author Yi-Cherng Su
蘇怡誠
spellingShingle Yi-Cherng Su
蘇怡誠
Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device
author_sort Yi-Cherng Su
title Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device
title_short Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device
title_full Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device
title_fullStr Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device
title_full_unstemmed Redesign and EMG Evaluation of a Finger-Operated Pointing Input Device
title_sort redesign and emg evaluation of a finger-operated pointing input device
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/mqy5r2
work_keys_str_mv AT yicherngsu redesignandemgevaluationofafingeroperatedpointinginputdevice
AT sūyíchéng redesignandemgevaluationofafingeroperatedpointinginputdevice
AT yicherngsu zhǐkòngdiǎnxuǎnshūrùzhuāngzhìzhīgǎishànshèjìyǔshǐyòngjīqúnpíláocèshì
AT sūyíchéng zhǐkòngdiǎnxuǎnshūrùzhuāngzhìzhīgǎishànshèjìyǔshǐyòngjīqúnpíláocèshì
_version_ 1719095298046820352