Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides

碩士 === 國立臺灣大學 === 化學研究所 === 95 === Trifluroacetic acid (TFA) is a commonly used ion-pair reagent in HPLC to improve peak shapes and hence the separation efficiency of peptides. However, TFA is known to cause significant signal suppression when analyzed by electrospray ionization mass spectrometry (E...

Full description

Bibliographic Details
Main Authors: Yih-Sin Ho, 何怡欣
Other Authors: 何國榮
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/78852419185903082601
id ndltd-TW-095NTU05065036
record_format oai_dc
spelling ndltd-TW-095NTU050650362015-12-07T04:04:10Z http://ndltd.ncl.edu.tw/handle/78852419185903082601 Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides 毛細管電層析質譜於胜肽分析界面之研究 Yih-Sin Ho 何怡欣 碩士 國立臺灣大學 化學研究所 95 Trifluroacetic acid (TFA) is a commonly used ion-pair reagent in HPLC to improve peak shapes and hence the separation efficiency of peptides. However, TFA is known to cause significant signal suppression when analyzed by electrospray ionization mass spectrometry (ESI-MS). In this study, we try to use TFA as mobile phase additive for capillary electrochromatography (CEC) in the analysis of peptides. Liquid junction interface is used and by manipulating the diameter of the spray tip and the ESI voltage applied, the introduction of make-up solution and TFA within into ESI-MS can be prevented successfully. However, the above interface has limited utility when applied in CEC because the flow rate of the spray tip is much higher than CEC flow rate. In order to match the flow rate of the tip and CEC column the optimized flow rate of ESI will not be achieved. Therefore, a low flow interface is introduced and placed in front of liquid junction interface to separate the ESI voltage, and the voltage applied on the make-up solution can be easily adjusted to match the flow rate of both sides of liquid junction without compromising the ESI optimized flow rate. By using liquid junction-low flow interface, it is possible to employ TFA in CEC for peptide separation and alleviate the suppression effect by TFA at the same time. 何國榮 2007 學位論文 ; thesis 97 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 化學研究所 === 95 === Trifluroacetic acid (TFA) is a commonly used ion-pair reagent in HPLC to improve peak shapes and hence the separation efficiency of peptides. However, TFA is known to cause significant signal suppression when analyzed by electrospray ionization mass spectrometry (ESI-MS). In this study, we try to use TFA as mobile phase additive for capillary electrochromatography (CEC) in the analysis of peptides. Liquid junction interface is used and by manipulating the diameter of the spray tip and the ESI voltage applied, the introduction of make-up solution and TFA within into ESI-MS can be prevented successfully. However, the above interface has limited utility when applied in CEC because the flow rate of the spray tip is much higher than CEC flow rate. In order to match the flow rate of the tip and CEC column the optimized flow rate of ESI will not be achieved. Therefore, a low flow interface is introduced and placed in front of liquid junction interface to separate the ESI voltage, and the voltage applied on the make-up solution can be easily adjusted to match the flow rate of both sides of liquid junction without compromising the ESI optimized flow rate. By using liquid junction-low flow interface, it is possible to employ TFA in CEC for peptide separation and alleviate the suppression effect by TFA at the same time.
author2 何國榮
author_facet 何國榮
Yih-Sin Ho
何怡欣
author Yih-Sin Ho
何怡欣
spellingShingle Yih-Sin Ho
何怡欣
Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides
author_sort Yih-Sin Ho
title Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides
title_short Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides
title_full Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides
title_fullStr Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides
title_full_unstemmed Use of low flow-liquid junction interface to alleviate sensitivity loss by Trifluoroacetic acid in the CEC-ESI/MS Analysis of peptides
title_sort use of low flow-liquid junction interface to alleviate sensitivity loss by trifluoroacetic acid in the cec-esi/ms analysis of peptides
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/78852419185903082601
work_keys_str_mv AT yihsinho useoflowflowliquidjunctioninterfacetoalleviatesensitivitylossbytrifluoroaceticacidinthececesimsanalysisofpeptides
AT héyíxīn useoflowflowliquidjunctioninterfacetoalleviatesensitivitylossbytrifluoroaceticacidinthececesimsanalysisofpeptides
AT yihsinho máoxìguǎndiàncéngxīzhìpǔyúshèngtàifēnxījièmiànzhīyánjiū
AT héyíxīn máoxìguǎndiàncéngxīzhìpǔyúshèngtàifēnxījièmiànzhīyánjiū
_version_ 1718145637880430592