Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater

碩士 === 國立臺灣海洋大學 === 食品科學系 === 95 === The efficiency of electrocoagulation on waste water treatment is dependent on the characteristics of water quality and operation parameters. The purposes of this study are to apply the electrocoagulation technology on the treatment of meat wastewater, and to unde...

Full description

Bibliographic Details
Main Authors: DONG-YUAN LIN, 林東源
Other Authors: Chyuan-Yuan Shiau, Ph. D.
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/70090366077047542079
id ndltd-TW-095NTOU5253048
record_format oai_dc
spelling ndltd-TW-095NTOU52530482015-10-13T13:47:38Z http://ndltd.ncl.edu.tw/handle/70090366077047542079 Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater 電混凝技術應用在肉品加工廢水處理之探討 DONG-YUAN LIN 林東源 碩士 國立臺灣海洋大學 食品科學系 95 The efficiency of electrocoagulation on waste water treatment is dependent on the characteristics of water quality and operation parameters. The purposes of this study are to apply the electrocoagulation technology on the treatment of meat wastewater, and to understand the influence of different pH and the addition of H2O2 on the operation efficiency. For inflow treated water of electrocoagulation, pH set to be 10 could obtain the best removal rate of turbidity, followed by pH 3 and pH 7. For outflow treated water, pH 10 is the best trying. On the conditions of different pH values, electric current 1.0A could obtain the best removal rate of turbidity. For the other water quality index, under the condition of 95% off of turbidity, we found that the best removal rate of total organic carbon (TOC) was at the condition of pH in- 3 and pH out-10. Better removal rate for NH3-N and COD was set at pH in- 10 and pH out- 10. The addition of 0.4 ml H2O2 could enhance the operation efficiency of electrocoagulation treatment, especially for inflow water with pH 7. The electrocoagulation time showed no marked effect on the efficiency of operation. Integrated the optimization parameters, under the conditions of pH (in-10, out-7), addition of 0.4 ml H2O2 and electric current set to be 1.0A, electrocoagulation could decrease the turbidity from 455 mg/L to 4 mg/L with removal rate of 99.2%. Consequently, the removal rate of TOC was 52%, NH3-N 31%, and COD 74%. Calculated from the removal of quality index, silt density index (SDI) was found greater than 7.5. The result showed that electrocoagulation could be a method for the treatment of meat processing wastewater. Keywords : Electrocoagulation, meat wastewater, water quality index, pH, H2O2 Chyuan-Yuan Shiau, Ph. D. 蕭泉源 2007 學位論文 ; thesis 115 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣海洋大學 === 食品科學系 === 95 === The efficiency of electrocoagulation on waste water treatment is dependent on the characteristics of water quality and operation parameters. The purposes of this study are to apply the electrocoagulation technology on the treatment of meat wastewater, and to understand the influence of different pH and the addition of H2O2 on the operation efficiency. For inflow treated water of electrocoagulation, pH set to be 10 could obtain the best removal rate of turbidity, followed by pH 3 and pH 7. For outflow treated water, pH 10 is the best trying. On the conditions of different pH values, electric current 1.0A could obtain the best removal rate of turbidity. For the other water quality index, under the condition of 95% off of turbidity, we found that the best removal rate of total organic carbon (TOC) was at the condition of pH in- 3 and pH out-10. Better removal rate for NH3-N and COD was set at pH in- 10 and pH out- 10. The addition of 0.4 ml H2O2 could enhance the operation efficiency of electrocoagulation treatment, especially for inflow water with pH 7. The electrocoagulation time showed no marked effect on the efficiency of operation. Integrated the optimization parameters, under the conditions of pH (in-10, out-7), addition of 0.4 ml H2O2 and electric current set to be 1.0A, electrocoagulation could decrease the turbidity from 455 mg/L to 4 mg/L with removal rate of 99.2%. Consequently, the removal rate of TOC was 52%, NH3-N 31%, and COD 74%. Calculated from the removal of quality index, silt density index (SDI) was found greater than 7.5. The result showed that electrocoagulation could be a method for the treatment of meat processing wastewater. Keywords : Electrocoagulation, meat wastewater, water quality index, pH, H2O2
author2 Chyuan-Yuan Shiau, Ph. D.
author_facet Chyuan-Yuan Shiau, Ph. D.
DONG-YUAN LIN
林東源
author DONG-YUAN LIN
林東源
spellingShingle DONG-YUAN LIN
林東源
Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater
author_sort DONG-YUAN LIN
title Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater
title_short Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater
title_full Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater
title_fullStr Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater
title_full_unstemmed Studies on the Application of Electrocoagulation Treatment on Meat Processing Wastewater
title_sort studies on the application of electrocoagulation treatment on meat processing wastewater
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/70090366077047542079
work_keys_str_mv AT dongyuanlin studiesontheapplicationofelectrocoagulationtreatmentonmeatprocessingwastewater
AT líndōngyuán studiesontheapplicationofelectrocoagulationtreatmentonmeatprocessingwastewater
AT dongyuanlin diànhùnníngjìshùyīngyòngzàiròupǐnjiāgōngfèishuǐchùlǐzhītàntǎo
AT líndōngyuán diànhùnníngjìshùyīngyòngzàiròupǐnjiāgōngfèishuǐchùlǐzhītàntǎo
_version_ 1717741485718241280