The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator
碩士 === 國立清華大學 === 動力機械工程學系 === 95 === Loop Heat Pipes (LHPs), which are generally and widely used with cylindrical evaporators, have a great potential for applications on spacecrafts and electronic cooling due to the advantages of high transfer capacity and long transport distances. However, the cyl...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2007
|
Online Access: | http://ndltd.ncl.edu.tw/handle/03375147476485247961 |
id |
ndltd-TW-095NTHU5311070 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-095NTHU53110702015-10-13T16:51:15Z http://ndltd.ncl.edu.tw/handle/03375147476485247961 The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator 平板型迴路式熱管散熱之研究 陳志嘉 碩士 國立清華大學 動力機械工程學系 95 Loop Heat Pipes (LHPs), which are generally and widely used with cylindrical evaporators, have a great potential for applications on spacecrafts and electronic cooling due to the advantages of high transfer capacity and long transport distances. However, the cylindrical evaporators of loop heat pipes cannot work on a flat thermo-contact surface without saddle. The saddle creates an extra thermal resistance. To avoid the above disadvantages, we utilize the flat evaporators of loop heat pipes. According to the literature, however, the heat leak problem is more serious in the flat evaporators than in the cylindrical evaporators. This problem also makes more difficult start-up and higher thermal resistance of flat evaporators. Hence this study uses stainless steel mesh and compares the affect of one or two primary wick structure. The results show that that method can ease heat leak problem, when flat evaporators of loop heat pipes have stainless steel mesh and two primary wick structures. Then loop heat pipes can start-up and work more easily at low load. Vapor flow resistance drops by four times and increases heat transfer when diameter of vapor line increases from 3mm to 4mm. When the temperature of the heater is less than 100 oC and the sink temperature is at 30oC, the maximum heat capacity reaches 140W for horizontal orientation and 170W for vertical orientation. 許文震 2007 學位論文 ; thesis 89 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立清華大學 === 動力機械工程學系 === 95 === Loop Heat Pipes (LHPs), which are generally and widely used with cylindrical evaporators, have a great potential for applications on spacecrafts and electronic cooling due to the advantages of high transfer capacity and long transport distances. However, the cylindrical evaporators of loop heat pipes cannot work on a flat thermo-contact surface without saddle. The saddle creates an extra thermal resistance. To avoid the above disadvantages, we utilize the flat evaporators of loop heat pipes. According to the literature, however, the heat leak problem is more serious in the flat evaporators than in the cylindrical evaporators. This problem also makes more difficult start-up and higher thermal resistance of flat evaporators. Hence this study uses stainless steel mesh and compares the affect of one or two primary wick structure. The results show that that method can ease heat leak problem, when flat evaporators of loop heat pipes have stainless steel mesh and two primary wick structures. Then loop heat pipes can start-up and work more easily at low load. Vapor flow resistance drops by four times and increases heat transfer when diameter of vapor line increases from 3mm to 4mm. When the temperature of the heater is less than 100 oC and the sink temperature is at 30oC, the maximum heat capacity reaches 140W for horizontal orientation and 170W for vertical orientation.
|
author2 |
許文震 |
author_facet |
許文震 陳志嘉 |
author |
陳志嘉 |
spellingShingle |
陳志嘉 The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator |
author_sort |
陳志嘉 |
title |
The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator |
title_short |
The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator |
title_full |
The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator |
title_fullStr |
The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator |
title_full_unstemmed |
The Thermal Performance Investigation of Loop Heat Pipe with Plate Evaporator |
title_sort |
thermal performance investigation of loop heat pipe with plate evaporator |
publishDate |
2007 |
url |
http://ndltd.ncl.edu.tw/handle/03375147476485247961 |
work_keys_str_mv |
AT chénzhìjiā thethermalperformanceinvestigationofloopheatpipewithplateevaporator AT chénzhìjiā píngbǎnxínghuílùshìrèguǎnsànrèzhīyánjiū AT chénzhìjiā thermalperformanceinvestigationofloopheatpipewithplateevaporator |
_version_ |
1717776089842974720 |