High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer
博士 === 國立清華大學 === 物理學系 === 95 === The Q & A experiment [1,2],aiming at the detection of vacuum birefringence predicted by quantum electrodynamics, consists mainly of a suspended 3.5 m Fabry-Perot interferometer, a rotating permanent dipole magnet and an ellipsometer. The permanent magnet, with m...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/13935467243595944612 |
id |
ndltd-TW-095NTHU5198002 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-095NTHU51980022016-05-25T04:13:40Z http://ndltd.ncl.edu.tw/handle/13935467243595944612 High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer 高精密光偏振量測與3.5米懸吊式Fabry-Perot干涉儀之回饋控制 Sheng-Jui Chen 陳生瑞 博士 國立清華大學 物理學系 95 The Q & A experiment [1,2],aiming at the detection of vacuum birefringence predicted by quantum electrodynamics, consists mainly of a suspended 3.5 m Fabry-Perot interferometer, a rotating permanent dipole magnet and an ellipsometer. The permanent magnet, with maximum central magnetic field of 2.3 T and field region length of 0.6 m, is used to polarize the vacuum (or gas) traversed by the light resonating inside the Fabry-Perot interferometer. To increase the detection sensitivity, the magnet is rotated at 5~10 rev/s to produce a time-dependent signal at twice the rotation frequency. The time-dependent signal is amplified 2F/\pi times by the Fabry-Perot interferometer, where F is the finesse of Fabry-Perot interferometer. For the last 3 months, the finesse F of the Fabry-Perot cavity is increased to 28,000~32,000 corresponding to a gain factor of 17,800~20,370. The feedback control system is improved to be more stable and less noisy, and an alignment control is successfully implemented on the Fabry-Perot interferometer. The ellipsometer is formed by a pair of Glan-Taylor type polarizing prism, a quarter-wave plate and a polarization rotation modulator. Without the quarter-wave plate, the ellipsometer becomes a polarization-rotation measuring instrument. The extinction ratio of the polarizing prism is lower than 5*10^{-9}. The apparatus is calibrated by performing the measurement of gaseous Cotton-Mouton effect (CME). The measurement of nitrogen CME is taken at several different pressures and room temperature of ~19.5 deg. C. The birefringence in nitrogen is measured to be \Delta n(N_2)=-(2.66+-0.12)*10^{-13}(B/1 T)^2(P/1 atm). The CME of air at the atmospheric pressure and room temperature 23.5 deg. C is also measured and the birefringence in air is \Delta n(air)=-(6.73+-0.26)*10^{-13}(B}/1 T)^2(P/1 atm). These results agree with other measurements found in the literature [70,79]. At present, the sensitivity for ellipticity detection is 5*10^{-7}rad.Hz}^{-1/2} at 10~20 Hz and that for polarization-rotation detection is 1.4*10^{-6}rad.Hz}^{-1/2} at 10~20 Hz. With this sensitivity, it is possible to check the polarization rotation effect recently observed by the PVLAS collaboration [29]. Our first results give (2.8+-2.8)*10^{-13} rad/pass, at B=2.3 T with 18,700 passes through a L=0.6 m long magnet (B^2L^2=1.6 T^2m^2). From the absence of an optical rotation, we were able to set a limit on axion coupling to two photons of g_{a\gamma\gamma}<1.7*10^{-6} GeV^{-1}, for axion mass m_a<2.2 meV. Wei-Tou Ni 倪維斗 2006 學位論文 ; thesis 227 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
博士 === 國立清華大學 === 物理學系 === 95 === The Q & A experiment [1,2],aiming at the detection of vacuum birefringence predicted by quantum electrodynamics,
consists mainly of a suspended 3.5 m Fabry-Perot interferometer, a rotating permanent dipole magnet and an ellipsometer. The permanent magnet,
with maximum central magnetic field of 2.3 T and field region length of 0.6 m, is used to polarize the vacuum (or gas) traversed by the light resonating inside the Fabry-Perot interferometer. To increase the detection sensitivity, the magnet is rotated at 5~10 rev/s to produce a time-dependent signal at twice the rotation frequency.
The time-dependent signal is amplified 2F/\pi times by the Fabry-Perot interferometer, where F is the finesse of Fabry-Perot interferometer. For the last 3 months, the finesse F of the Fabry-Perot cavity is increased to 28,000~32,000 corresponding to a gain factor of 17,800~20,370. The feedback control system is improved to be more stable and less noisy, and an alignment control is successfully implemented on the Fabry-Perot interferometer.
The ellipsometer is formed by a pair of Glan-Taylor type polarizing prism, a quarter-wave plate and a polarization rotation modulator. Without the quarter-wave plate, the ellipsometer becomes a polarization-rotation measuring instrument. The extinction ratio of the polarizing prism is lower than 5*10^{-9}. The apparatus is calibrated by performing the measurement of gaseous Cotton-Mouton effect (CME). The measurement of nitrogen CME is taken at several different pressures and room temperature of ~19.5 deg. C.
The birefringence in nitrogen is measured to be \Delta n(N_2)=-(2.66+-0.12)*10^{-13}(B/1 T)^2(P/1 atm).
The CME of air at the atmospheric pressure and room temperature 23.5 deg. C is also measured and the birefringence in air is \Delta n(air)=-(6.73+-0.26)*10^{-13}(B}/1 T)^2(P/1 atm). These results agree with other measurements found in the literature [70,79]. At present,
the sensitivity for ellipticity detection is 5*10^{-7}rad.Hz}^{-1/2} at 10~20 Hz and that for polarization-rotation detection is 1.4*10^{-6}rad.Hz}^{-1/2} at 10~20 Hz.
With this sensitivity, it is possible to check the polarization rotation effect recently observed by the PVLAS collaboration [29]. Our first results give (2.8+-2.8)*10^{-13} rad/pass, at B=2.3 T with 18,700 passes through a L=0.6 m long magnet (B^2L^2=1.6 T^2m^2). From the absence of an optical rotation, we were able to set a limit on axion coupling to two photons of g_{a\gamma\gamma}<1.7*10^{-6} GeV^{-1}, for axion mass m_a<2.2 meV.
|
author2 |
Wei-Tou Ni |
author_facet |
Wei-Tou Ni Sheng-Jui Chen 陳生瑞 |
author |
Sheng-Jui Chen 陳生瑞 |
spellingShingle |
Sheng-Jui Chen 陳生瑞 High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer |
author_sort |
Sheng-Jui Chen |
title |
High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer |
title_short |
High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer |
title_full |
High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer |
title_fullStr |
High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer |
title_full_unstemmed |
High precision measurement of optical polarization and feedback control of the 3.5 m suspended Fabry-Perot interferometer |
title_sort |
high precision measurement of optical polarization and feedback control of the 3.5 m suspended fabry-perot interferometer |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/13935467243595944612 |
work_keys_str_mv |
AT shengjuichen highprecisionmeasurementofopticalpolarizationandfeedbackcontrolofthe35msuspendedfabryperotinterferometer AT chénshēngruì highprecisionmeasurementofopticalpolarizationandfeedbackcontrolofthe35msuspendedfabryperotinterferometer AT shengjuichen gāojīngmìguāngpiānzhènliàngcèyǔ35mǐxuándiàoshìfabryperotgànshèyízhīhuíkuìkòngzhì AT chénshēngruì gāojīngmìguāngpiānzhènliàngcèyǔ35mǐxuándiàoshìfabryperotgànshèyízhīhuíkuìkòngzhì |
_version_ |
1718280022511321088 |