Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter
碩士 === 國立屏東科技大學 === 機械工程系所 === 95 === Abstract Student ID: M9432030 Title of Thesis: Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter Name of Institute: National Pingtung University of Science and Technology Total Pages: 73 Name of Department: Department...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2007
|
Online Access: | http://ndltd.ncl.edu.tw/handle/93365592893223118688 |
id |
ndltd-TW-095NPUS5489038 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-095NPUS54890382016-12-22T04:11:53Z http://ndltd.ncl.edu.tw/handle/93365592893223118688 Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter 鐵氟龍與銅管科氏力式質量流率計實驗分析及比較 Jhao-Kuan Wei 魏肇寬 碩士 國立屏東科技大學 機械工程系所 95 Abstract Student ID: M9432030 Title of Thesis: Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter Name of Institute: National Pingtung University of Science and Technology Total Pages: 73 Name of Department: Department of Mechanical Engineering Date of Graduation: June, 2007 Degree Conferred: Master Name of Student: Jhao-Kuan Wei Adviser: Hsu-Jeng Liu The Contents of Abstract in this Thesis: This thesis analyze, compare Coriolis mass flowmeter with different tube and different material. First, we build Copper tube and Teflon tube Coriolis mass flowmeter respectively, and we present the essential frame and the design theory of the Coriolis mass flowmeter; and Applying Experiment Modal Analysis to analyze the each shape and tube’s modal analysis, and to find the Coriolis frequency for excitability. The relation between Hall sensor’s magnetic field effect and stimulating sources is being correct discussion, and to find out each tube under the single one stimulating force the different flow rate, to get phase difference with different flow rate will be linear and distance of sensor which don’t contact, according to analysis, to make each tube Coriolis mass flowmeter. Stimulating sources is used Matlab-xPC Hardware equipment to produce the excitation frequency, and the drive coil and magnet will be magnetize to produce the excitation frequency. To measurement the signal by Hall sensor that is mounted at upstream and downstream flow of the tube, then we use Matlab-xPC Hardware to filter single processing, we can measure the mass flow rate and signal analysis immediately. After we can find the accuracy of the 5 tube Coriolis mass flowmeter good than teflon tube Coriolis mass flowmeter. Keywords: Coriolis mass flowmeter, Matlab-xPC, signal process Hsu-Jeng Liu 劉思正 2007 學位論文 ; thesis 73 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立屏東科技大學 === 機械工程系所 === 95 === Abstract
Student ID: M9432030
Title of Thesis: Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter
Name of Institute: National Pingtung University of Science and Technology
Total Pages: 73
Name of Department: Department of Mechanical Engineering
Date of Graduation: June, 2007 Degree Conferred: Master
Name of Student: Jhao-Kuan Wei Adviser: Hsu-Jeng Liu
The Contents of Abstract in this Thesis:
This thesis analyze, compare Coriolis mass flowmeter with different tube and different material. First, we build Copper tube and Teflon tube Coriolis mass flowmeter respectively, and we present the essential frame and the design theory of the Coriolis mass flowmeter; and Applying Experiment Modal Analysis to analyze the each shape and tube’s modal analysis, and to find the Coriolis frequency for excitability. The relation between Hall sensor’s magnetic field effect and stimulating sources is being correct discussion, and to find out each tube under the single one stimulating force the different flow rate, to get phase difference with different flow rate will be linear and distance of sensor which don’t contact, according to analysis, to make each tube Coriolis mass flowmeter. Stimulating sources is used Matlab-xPC Hardware equipment to produce the excitation frequency, and the drive coil and magnet will be magnetize to produce the excitation frequency. To measurement the signal by Hall sensor that is mounted at upstream and downstream flow of the tube, then we use Matlab-xPC Hardware to filter single processing, we can measure the mass flow rate and signal analysis immediately. After we can find the accuracy of the 5 tube Coriolis mass flowmeter good than teflon tube Coriolis mass flowmeter.
Keywords: Coriolis mass flowmeter, Matlab-xPC, signal process
|
author2 |
Hsu-Jeng Liu |
author_facet |
Hsu-Jeng Liu Jhao-Kuan Wei 魏肇寬 |
author |
Jhao-Kuan Wei 魏肇寬 |
spellingShingle |
Jhao-Kuan Wei 魏肇寬 Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter |
author_sort |
Jhao-Kuan Wei |
title |
Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter |
title_short |
Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter |
title_full |
Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter |
title_fullStr |
Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter |
title_full_unstemmed |
Experimental Analysis and Comparison of Teflon Versus Copper Tube Coriolis Mass Flowmeter |
title_sort |
experimental analysis and comparison of teflon versus copper tube coriolis mass flowmeter |
publishDate |
2007 |
url |
http://ndltd.ncl.edu.tw/handle/93365592893223118688 |
work_keys_str_mv |
AT jhaokuanwei experimentalanalysisandcomparisonofteflonversuscoppertubecoriolismassflowmeter AT wèizhàokuān experimentalanalysisandcomparisonofteflonversuscoppertubecoriolismassflowmeter AT jhaokuanwei tiěfúlóngyǔtóngguǎnkēshìlìshìzhìliàngliúlǜjìshíyànfēnxījíbǐjiào AT wèizhàokuān tiěfúlóngyǔtóngguǎnkēshìlìshìzhìliàngliúlǜjìshíyànfēnxījíbǐjiào |
_version_ |
1718402467718234112 |