Water Uptake of the UV-treated Polyimide Film
碩士 === 國立高雄應用科技大學 === 化學工程系碩士班 === 95 === The feasibility studies on the decline in the water uptake for the some commercialized PI films were thoroughly investigated by exposing these films to the different intensities of UV light. UV radiation on the surface of the PI film results in the chemical...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2007
|
Online Access: | http://ndltd.ncl.edu.tw/handle/21708110115890263974 |
id |
ndltd-TW-095KUAS0063036 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-095KUAS00630362016-05-23T04:17:18Z http://ndltd.ncl.edu.tw/handle/21708110115890263974 Water Uptake of the UV-treated Polyimide Film UV光表面處理聚醯亞胺薄膜之吸水率研究 Yu E Chen 陳鈺鋨 碩士 國立高雄應用科技大學 化學工程系碩士班 95 The feasibility studies on the decline in the water uptake for the some commercialized PI films were thoroughly investigated by exposing these films to the different intensities of UV light. UV radiation on the surface of the PI film results in the chemical reactions, usually crosslinking, and hence the water uptake, gas permeability, thermal properties, and mechanical properties. The water uptake for TaiFlex PI film declined by 17.5% and DuPont Kapton 50H film by 11%. The thermal stability for TaiFlex PI film did not alter, but its tensile strength increased as the times of UV exposure increased. Alternatively, ionic migration within the 2L FCCL (2 layer Flexible Copper Clad Laminate) slightly decrease, probably due to that the crosslinking takes place. Rong-Hsien Lin Wen-Chung OuYang 林榮顯 歐陽文忠 2007 學位論文 ; thesis 49 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立高雄應用科技大學 === 化學工程系碩士班 === 95 === The feasibility studies on the decline in the water uptake for the some commercialized PI films were thoroughly investigated by exposing these films to the different intensities of UV light. UV radiation on the surface of the PI film results in the chemical reactions, usually crosslinking, and hence the water uptake, gas permeability, thermal properties, and mechanical properties.
The water uptake for TaiFlex PI film declined by 17.5% and DuPont Kapton 50H film by 11%. The thermal stability for TaiFlex PI film did not alter, but its tensile strength increased as the times of UV exposure increased. Alternatively, ionic migration within the 2L FCCL (2 layer Flexible Copper Clad Laminate) slightly decrease, probably due to that the crosslinking takes place.
|
author2 |
Rong-Hsien Lin |
author_facet |
Rong-Hsien Lin Yu E Chen 陳鈺鋨 |
author |
Yu E Chen 陳鈺鋨 |
spellingShingle |
Yu E Chen 陳鈺鋨 Water Uptake of the UV-treated Polyimide Film |
author_sort |
Yu E Chen |
title |
Water Uptake of the UV-treated Polyimide Film |
title_short |
Water Uptake of the UV-treated Polyimide Film |
title_full |
Water Uptake of the UV-treated Polyimide Film |
title_fullStr |
Water Uptake of the UV-treated Polyimide Film |
title_full_unstemmed |
Water Uptake of the UV-treated Polyimide Film |
title_sort |
water uptake of the uv-treated polyimide film |
publishDate |
2007 |
url |
http://ndltd.ncl.edu.tw/handle/21708110115890263974 |
work_keys_str_mv |
AT yuechen wateruptakeoftheuvtreatedpolyimidefilm AT chényùtiě wateruptakeoftheuvtreatedpolyimidefilm AT yuechen uvguāngbiǎomiànchùlǐjùxīyàànbáomózhīxīshuǐlǜyánjiū AT chényùtiě uvguāngbiǎomiànchùlǐjùxīyàànbáomózhīxīshuǐlǜyánjiū |
_version_ |
1718276762555645952 |