dose response of Gafchromic films EBT to high energy x-ray and electron beams
碩士 === 高雄醫學大學 === 醫學放射技術學研究所碩士班 === 95 === The object of this experiment is to confer the dose response of high energy x-ray, electron beams, single or fraction irradiation, and try to find its correlation. Different energy of dose of x-ray and electron beams exposure dividedly collected single and...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2007
|
Online Access: | http://ndltd.ncl.edu.tw/handle/48464172292446086778 |
id |
ndltd-TW-095KMC05605002 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-095KMC056050022016-05-23T04:18:10Z http://ndltd.ncl.edu.tw/handle/48464172292446086778 dose response of Gafchromic films EBT to high energy x-ray and electron beams GafchromicfilmEBT對於高能x光與電子之劑量回應關係 Ching-Yu Chang 張瀞予 碩士 高雄醫學大學 醫學放射技術學研究所碩士班 95 The object of this experiment is to confer the dose response of high energy x-ray, electron beams, single or fraction irradiation, and try to find its correlation. Different energy of dose of x-ray and electron beams exposure dividedly collected single and fraction irradiation was made by Varian 2100C accelerator when using the ISP Gafchromic film (RCF) EBT. All the RCF film was read and scanned by digital densitometer after 24 hours. The optic density (OD) value was collected and analyzed. It was using different dose to measure the OD value by single and fraction irradiation. When random access dose (50-800 cGy) was verified, the reproducibility was acceptable. The result shows that RCF film is out of energy dependence, no apparent difference between single and fraction irradiation, and it can be re-usable by the data analysis. Paosh Chang 張寶樹 2007 學位論文 ; thesis 34 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 高雄醫學大學 === 醫學放射技術學研究所碩士班 === 95 === The object of this experiment is to confer the dose response of high energy x-ray, electron beams, single or fraction irradiation, and try to find its correlation. Different energy of dose of x-ray and electron beams exposure dividedly collected single and fraction irradiation was made by Varian 2100C accelerator when using the ISP Gafchromic film (RCF) EBT. All the RCF film was read and scanned by digital densitometer after 24 hours. The optic density (OD) value was collected and analyzed. It was using different dose to measure the OD value by single and fraction irradiation.
When random access dose (50-800 cGy) was verified, the reproducibility was acceptable. The result shows that RCF film is out of energy dependence, no apparent difference between single and fraction irradiation, and it can be re-usable by the data analysis.
|
author2 |
Paosh Chang |
author_facet |
Paosh Chang Ching-Yu Chang 張瀞予 |
author |
Ching-Yu Chang 張瀞予 |
spellingShingle |
Ching-Yu Chang 張瀞予 dose response of Gafchromic films EBT to high energy x-ray and electron beams |
author_sort |
Ching-Yu Chang |
title |
dose response of Gafchromic films EBT to high energy x-ray and electron beams |
title_short |
dose response of Gafchromic films EBT to high energy x-ray and electron beams |
title_full |
dose response of Gafchromic films EBT to high energy x-ray and electron beams |
title_fullStr |
dose response of Gafchromic films EBT to high energy x-ray and electron beams |
title_full_unstemmed |
dose response of Gafchromic films EBT to high energy x-ray and electron beams |
title_sort |
dose response of gafchromic films ebt to high energy x-ray and electron beams |
publishDate |
2007 |
url |
http://ndltd.ncl.edu.tw/handle/48464172292446086778 |
work_keys_str_mv |
AT chingyuchang doseresponseofgafchromicfilmsebttohighenergyxrayandelectronbeams AT zhāngjìngyǔ doseresponseofgafchromicfilmsebttohighenergyxrayandelectronbeams AT chingyuchang gafchromicfilmebtduìyúgāonéngxguāngyǔdiànzizhījìliànghuíyīngguānxì AT zhāngjìngyǔ gafchromicfilmebtduìyúgāonéngxguāngyǔdiànzizhījìliànghuíyīngguānxì |
_version_ |
1718279150372913152 |