Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber

碩士 === 大葉大學 === 電信工程學系碩士班 === 95 === ABSTRACT With the rapid advent of modern science, our living environment has been crammed with electromagnetic radiation interferences. This in turn causes a severe degradation of the instrument and equipment. Therefore, countries all over the world have passed...

Full description

Bibliographic Details
Main Authors: Po-Hsun Huang, 黃柏勳
Other Authors: Han-Nien Lin
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/90513998532864202186
id ndltd-TW-095DYU00435002
record_format oai_dc
spelling ndltd-TW-095DYU004350022016-05-25T04:14:21Z http://ndltd.ncl.edu.tw/handle/90513998532864202186 Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber 輻射源位置對電波迴響室場均勻度與等向性之效應 Po-Hsun Huang 黃柏勳 碩士 大葉大學 電信工程學系碩士班 95 ABSTRACT With the rapid advent of modern science, our living environment has been crammed with electromagnetic radiation interferences. This in turn causes a severe degradation of the instrument and equipment. Therefore, countries all over the world have passed strict requirement for EMC specification for all general electronic products. This work studied the utilization of Reverberation Chamber as a newly developed EMC test site. A Reverberation Chamber is basically a metal shielded room with metal stirrers whose function is to control the field distribution inside a working volume inside the chamber by changing the boundary conditions of the electromagnetic field inside the chamber. Comparing with the anechoic chamber, the reverberation chamber does not require expensive absorber material and medium high power amplifier for operation. More importantly is the chamber ability to generate a statistical uniform and isotropic field which can meet the stringent requirement when performing the EMS test. Because of the low cost and enhanced efficiency, the reverberation chamber has become the preferred test facility. In this thesis, we investigate and discuss the effect on field uniformity and isotropicity inside the work volume of a reverberation chamber by changing the location and direction of transmitting antenna. A comparison between electromagnetic numerical analysis and measurements were being made. Han-Nien Lin Cheng-Nan Chiu 林漢年 邱政男 2007 學位論文 ; thesis 93 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 大葉大學 === 電信工程學系碩士班 === 95 === ABSTRACT With the rapid advent of modern science, our living environment has been crammed with electromagnetic radiation interferences. This in turn causes a severe degradation of the instrument and equipment. Therefore, countries all over the world have passed strict requirement for EMC specification for all general electronic products. This work studied the utilization of Reverberation Chamber as a newly developed EMC test site. A Reverberation Chamber is basically a metal shielded room with metal stirrers whose function is to control the field distribution inside a working volume inside the chamber by changing the boundary conditions of the electromagnetic field inside the chamber. Comparing with the anechoic chamber, the reverberation chamber does not require expensive absorber material and medium high power amplifier for operation. More importantly is the chamber ability to generate a statistical uniform and isotropic field which can meet the stringent requirement when performing the EMS test. Because of the low cost and enhanced efficiency, the reverberation chamber has become the preferred test facility. In this thesis, we investigate and discuss the effect on field uniformity and isotropicity inside the work volume of a reverberation chamber by changing the location and direction of transmitting antenna. A comparison between electromagnetic numerical analysis and measurements were being made.
author2 Han-Nien Lin
author_facet Han-Nien Lin
Po-Hsun Huang
黃柏勳
author Po-Hsun Huang
黃柏勳
spellingShingle Po-Hsun Huang
黃柏勳
Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber
author_sort Po-Hsun Huang
title Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber
title_short Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber
title_full Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber
title_fullStr Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber
title_full_unstemmed Effect of Radiation Source Location on Field Uniformity and Isotropicity Inside Reverberation Chamber
title_sort effect of radiation source location on field uniformity and isotropicity inside reverberation chamber
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/90513998532864202186
work_keys_str_mv AT pohsunhuang effectofradiationsourcelocationonfielduniformityandisotropicityinsidereverberationchamber
AT huángbǎixūn effectofradiationsourcelocationonfielduniformityandisotropicityinsidereverberationchamber
AT pohsunhuang fúshèyuánwèizhìduìdiànbōhuíxiǎngshìchǎngjūnyúndùyǔděngxiàngxìngzhīxiàoyīng
AT huángbǎixūn fúshèyuánwèizhìduìdiànbōhuíxiǎngshìchǎngjūnyúndùyǔděngxiàngxìngzhīxiàoyīng
_version_ 1718280518632472576