Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations

碩士 === 中山醫學大學 === 口腔材料科學研究所 === 95 === Hydroxyapatite coating have been used as load-bearing implant applications. The aim of this work is to deposit functionally graded HA/Ti layers using plasma spray to improve the coating-substrate interface properties. In addition to the Ti bondcoat and the top...

Full description

Bibliographic Details
Main Authors: Bo-Ren, 簡柏仁
Other Authors: 丁信智
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/73191184641387270247
id ndltd-TW-095CSMU5660005
record_format oai_dc
spelling ndltd-TW-095CSMU56600052015-10-28T04:07:06Z http://ndltd.ncl.edu.tw/handle/73191184641387270247 Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations 牙科植體用新型氫氧基磷灰石/鈦複合漸層之性質 Bo-Ren 簡柏仁 碩士 中山醫學大學 口腔材料科學研究所 95 Hydroxyapatite coating have been used as load-bearing implant applications. The aim of this work is to deposit functionally graded HA/Ti layers using plasma spray to improve the coating-substrate interface properties. In addition to the Ti bondcoat and the top HA biolayer, the alternating layers were created by means of changing the feeding rate and input powder of Ti and HA. The stability of the graded coatings such as corrosion resistance and fatigue, and bonding strength of the potential graded coatings without and with post-deposition heat treatment were examined. Results showed that surface chemistry and morphology of the graded coatings were similar to those of monolithic HA coatings. The bonding strength values of the as-sprayed graded coating were much superior to those of monolithic HA coatings. The cyclic fatigue did have a statistically significant effect on bond strength of monolithic HA coatings, with a decrease of 23%. However, the graded coatings were able to survive 1 million cycles of loading in air without significantly reduced bond strength. The in vitro electrochemical measurement results also indicated that the graded coatings had a more beneficial and desired behavior than monolithic HA coatings after fatigue. An appropriate heat treatment resulted in recrystallization of amorphous calcium phosphate of as-sprayed coatings. The enhancement of the resistance to corrosion took place after heat treatment. Consequently, we concluded that the heat treatment at 600℃, endowing with increased crystallinity and the reduced defects as well as enhanced bond strength, may be a suitable post-deposition treatment method to promote the characteristics of graded HA/Ti coatings. 丁信智 2007 學位論文 ; thesis 44 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中山醫學大學 === 口腔材料科學研究所 === 95 === Hydroxyapatite coating have been used as load-bearing implant applications. The aim of this work is to deposit functionally graded HA/Ti layers using plasma spray to improve the coating-substrate interface properties. In addition to the Ti bondcoat and the top HA biolayer, the alternating layers were created by means of changing the feeding rate and input powder of Ti and HA. The stability of the graded coatings such as corrosion resistance and fatigue, and bonding strength of the potential graded coatings without and with post-deposition heat treatment were examined. Results showed that surface chemistry and morphology of the graded coatings were similar to those of monolithic HA coatings. The bonding strength values of the as-sprayed graded coating were much superior to those of monolithic HA coatings. The cyclic fatigue did have a statistically significant effect on bond strength of monolithic HA coatings, with a decrease of 23%. However, the graded coatings were able to survive 1 million cycles of loading in air without significantly reduced bond strength. The in vitro electrochemical measurement results also indicated that the graded coatings had a more beneficial and desired behavior than monolithic HA coatings after fatigue. An appropriate heat treatment resulted in recrystallization of amorphous calcium phosphate of as-sprayed coatings. The enhancement of the resistance to corrosion took place after heat treatment. Consequently, we concluded that the heat treatment at 600℃, endowing with increased crystallinity and the reduced defects as well as enhanced bond strength, may be a suitable post-deposition treatment method to promote the characteristics of graded HA/Ti coatings.
author2 丁信智
author_facet 丁信智
Bo-Ren
簡柏仁
author Bo-Ren
簡柏仁
spellingShingle Bo-Ren
簡柏仁
Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
author_sort Bo-Ren
title Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
title_short Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
title_full Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
title_fullStr Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
title_full_unstemmed Properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
title_sort properties of novel hydroxyapatite/titanium gradient coatings for dental implantations
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/73191184641387270247
work_keys_str_mv AT boren propertiesofnovelhydroxyapatitetitaniumgradientcoatingsfordentalimplantations
AT jiǎnbǎirén propertiesofnovelhydroxyapatitetitaniumgradientcoatingsfordentalimplantations
AT boren yákēzhítǐyòngxīnxíngqīngyǎngjīlínhuīshítàifùhéjiàncéngzhīxìngzhì
AT jiǎnbǎirén yákēzhítǐyòngxīnxíngqīngyǎngjīlínhuīshítàifùhéjiàncéngzhīxìngzhì
_version_ 1718112321324187648