Microfluidic PCR Device Using Two-stage Thermal Cycling
碩士 === 大同大學 === 生物工程學系(所) === 94 === Polymerase chain reaction (PCR) is normally carried out under three specific temperatures. An integrated microfluidic PCR device was developed using microfabrication techniques. The device employed a two-stage thermal cycling. By performing annealing and elongati...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/07767888509509327458 |
id |
ndltd-TW-094TTU00106018 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094TTU001060182016-06-01T04:21:09Z http://ndltd.ncl.edu.tw/handle/07767888509509327458 Microfluidic PCR Device Using Two-stage Thermal Cycling 兩段式熱循環微流道PCR晶片 Wen-Shian Liang 梁文憲 碩士 大同大學 生物工程學系(所) 94 Polymerase chain reaction (PCR) is normally carried out under three specific temperatures. An integrated microfluidic PCR device was developed using microfabrication techniques. The device employed a two-stage thermal cycling. By performing annealing and elongation under the same temperature, the cycle time can be decreased and the total cycle number can be increased. The 70 mm deep flow channels were casted using polydimethylsiloxane (PDMS). A chromium layer was sputtered on Corning 1737 glass then etched and used as heaters. The glass and the polymer were bonded together to form enclosed channels. Thirty PCR cycles were manufactured in this 5.5 cm×4.0 cm device. The chip successfully amplified a 298 bp fragment from D-amino acid oxidase gene (Trigonopsis variabilis) with similar efficiency when compared to a thermal cycler. The effects of fragment length and several additives (BSA, PEG, PVP, and Triton X-100) on the device where also tested. Chi-yang Yu 游吉陽 2006 學位論文 ; thesis 70 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 大同大學 === 生物工程學系(所) === 94 === Polymerase chain reaction (PCR) is normally carried out under three specific temperatures. An integrated microfluidic PCR device was developed using microfabrication techniques. The device employed a two-stage thermal cycling. By performing annealing and elongation under the same temperature, the cycle time can be decreased and the total cycle number can be increased. The 70 mm deep flow channels were casted using polydimethylsiloxane (PDMS). A chromium layer was sputtered on Corning 1737 glass then etched and used as heaters. The glass and the polymer were bonded together to form enclosed channels. Thirty PCR cycles were manufactured in this 5.5 cm×4.0 cm device. The chip successfully amplified a 298 bp fragment from D-amino acid oxidase gene (Trigonopsis variabilis) with similar efficiency when compared to a thermal cycler. The effects of fragment length and several additives (BSA, PEG, PVP, and Triton X-100) on the device where also tested.
|
author2 |
Chi-yang Yu |
author_facet |
Chi-yang Yu Wen-Shian Liang 梁文憲 |
author |
Wen-Shian Liang 梁文憲 |
spellingShingle |
Wen-Shian Liang 梁文憲 Microfluidic PCR Device Using Two-stage Thermal Cycling |
author_sort |
Wen-Shian Liang |
title |
Microfluidic PCR Device Using Two-stage Thermal Cycling |
title_short |
Microfluidic PCR Device Using Two-stage Thermal Cycling |
title_full |
Microfluidic PCR Device Using Two-stage Thermal Cycling |
title_fullStr |
Microfluidic PCR Device Using Two-stage Thermal Cycling |
title_full_unstemmed |
Microfluidic PCR Device Using Two-stage Thermal Cycling |
title_sort |
microfluidic pcr device using two-stage thermal cycling |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/07767888509509327458 |
work_keys_str_mv |
AT wenshianliang microfluidicpcrdeviceusingtwostagethermalcycling AT liángwénxiàn microfluidicpcrdeviceusingtwostagethermalcycling AT wenshianliang liǎngduànshìrèxúnhuánwēiliúdàopcrjīngpiàn AT liángwénxiàn liǎngduànshìrèxúnhuánwēiliúdàopcrjīngpiàn |
_version_ |
1718289152346161152 |