Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water
碩士 === 靜宜大學 === 應用化學研究所 === 94 === This work is divide into two part: The first part: We proposed an electronic tongue system that includes a newly developed chemical sensor array comprising six chemical sensors. Sensing materials are different mixtures of polymers, conducting polymer and liposome....
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/gf5g6w |
id |
ndltd-TW-094PU005500021 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094PU0055000212018-06-25T06:05:10Z http://ndltd.ncl.edu.tw/handle/gf5g6w Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water 阻抗分析技術應用在運動飲料及廢水中鉻的偵測研究 Cheng-Hsiu Yeh 葉政修 碩士 靜宜大學 應用化學研究所 94 This work is divide into two part: The first part: We proposed an electronic tongue system that includes a newly developed chemical sensor array comprising six chemical sensors. Sensing materials are different mixtures of polymers, conducting polymer and liposome. We use some different materials to compose chemical sensors and determine conductivity. The experiment results show that the sensed signals are successfully classified by principal component analysis (PCA) method. Different frequencies were scanned on standard solutions of taste sensor electrode using LCZ meter and appropriate frequency value was obtained as a parameter for measuring the samples. Various kinds of commercial sports drink are analyzed by the PCA method with focus on the salt region. Five of the sport drinks determination of the concentration respectively(6.47,27.83,14.15 ,22.48,19.5mM.) The second part: we proposed two various electrodes ,the sensing materials included different plasticizers (DOS,CN), ionophore, (C-thiophenecalix resorcinarene) etc. We used the two sensors to determination the standard chromium solutions (VI) 0.1,1,10,100,1000ppm and four waste water. The concentration of the waste water determined respectively (2510,10500,10.2,12.5ppm). Measurement principle of the sensor array is the impedance parameter of solutions. The equivalent circuits are the combination of capacitance and resistance. Circuits are obtained by using the cole-cole plot technology. Ran-Jang Wu Hung-Wei Chen 吳仁彰 陳宏偉 2006 學位論文 ; thesis 78 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 靜宜大學 === 應用化學研究所 === 94 === This work is divide into two part: The first part: We proposed an electronic tongue system that includes a newly developed chemical sensor array comprising six chemical sensors. Sensing materials are different mixtures of polymers, conducting polymer and liposome. We use some different materials to compose chemical sensors and determine conductivity. The experiment results show that the sensed signals are successfully classified by principal component analysis (PCA) method. Different frequencies were scanned on standard solutions of taste sensor electrode using LCZ meter and appropriate frequency value was obtained as a parameter for measuring the samples. Various kinds of commercial sports drink are analyzed by the PCA method with focus on the salt region. Five of the sport drinks determination of the concentration respectively(6.47,27.83,14.15 ,22.48,19.5mM.)
The second part: we proposed two various electrodes ,the sensing materials included different plasticizers (DOS,CN), ionophore, (C-thiophenecalix resorcinarene) etc. We used the two sensors to determination the standard chromium solutions (VI) 0.1,1,10,100,1000ppm and four waste water. The concentration of the waste water determined respectively (2510,10500,10.2,12.5ppm).
Measurement principle of the sensor array is the impedance parameter of solutions. The equivalent circuits are the combination of capacitance and resistance. Circuits are obtained by using the cole-cole plot technology.
|
author2 |
Ran-Jang Wu |
author_facet |
Ran-Jang Wu Cheng-Hsiu Yeh 葉政修 |
author |
Cheng-Hsiu Yeh 葉政修 |
spellingShingle |
Cheng-Hsiu Yeh 葉政修 Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water |
author_sort |
Cheng-Hsiu Yeh |
title |
Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water |
title_short |
Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water |
title_full |
Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water |
title_fullStr |
Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water |
title_full_unstemmed |
Impedance measurement technology application for sport drink and determination Cr(VI) in the waste water |
title_sort |
impedance measurement technology application for sport drink and determination cr(vi) in the waste water |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/gf5g6w |
work_keys_str_mv |
AT chenghsiuyeh impedancemeasurementtechnologyapplicationforsportdrinkanddeterminationcrviinthewastewater AT yèzhèngxiū impedancemeasurementtechnologyapplicationforsportdrinkanddeterminationcrviinthewastewater AT chenghsiuyeh zǔkàngfēnxījìshùyīngyòngzàiyùndòngyǐnliàojífèishuǐzhōngluòdezhēncèyánjiū AT yèzhèngxiū zǔkàngfēnxījìshùyīngyòngzàiyùndòngyǐnliàojífèishuǐzhōngluòdezhēncèyánjiū |
_version_ |
1718704789654601728 |