Studies of Modified Titanium oxide Electrodes

碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 94 === The paper relates to a process for producing a metal probe tip having a sharp point. A computer controlled instrument and reversed dip etching process characterizes the tip while in formation and reliably produces tips having a radius of curvature of approxi...

Full description

Bibliographic Details
Main Authors: Chi-Chum Yang, 楊啟全
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/nq86x6
id ndltd-TW-094NYPI5124028
record_format oai_dc
spelling ndltd-TW-094NYPI51240282019-09-24T03:34:25Z http://ndltd.ncl.edu.tw/handle/nq86x6 Studies of Modified Titanium oxide Electrodes 氧化鈦修飾電極的研究 Chi-Chum Yang 楊啟全 碩士 國立虎尾科技大學 光電與材料科技研究所 94 The paper relates to a process for producing a metal probe tip having a sharp point. A computer controlled instrument and reversed dip etching process characterizes the tip while in formation and reliably produces tips having a radius of curvature of approximately 10μm. In the paper, the position of the metal wire during the reversed-dip-etching operation is mechanically controlled while the etching solution is monitored. A new pH sensor based on a novel oxidized titanium electrode is prepared and its characteristics discussed as well. Titanium electrodes were anodized in DMSO organic solution by applying DC voltages (6V~160V) to form various titanium oxide thin films. The dry (stored in dry air) anodized titanium electrode has a super-Nernstian response with a slope of 66.0 mV/pH unit, and the wet (stored in 4M KCl solution) anodized titanium electrode has a near Nernstian response with a slope of 59.0 mV/pH unit. Responses over a pH range 2 ~ 12 are linear. A self-assembled Prussian blue (PB) on titanium microelectrode with modified Nafion is described. The modified electrode showed high sensitivity when used in the determination of potassium ion concentration. It can effectively eliminate the interference of H+ ion after coated PB with modified Nafion. This electrode can be used in the determination of the time since death (postmortem interval, PMI). 2006 學位論文 ; thesis 201 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 94 === The paper relates to a process for producing a metal probe tip having a sharp point. A computer controlled instrument and reversed dip etching process characterizes the tip while in formation and reliably produces tips having a radius of curvature of approximately 10μm. In the paper, the position of the metal wire during the reversed-dip-etching operation is mechanically controlled while the etching solution is monitored. A new pH sensor based on a novel oxidized titanium electrode is prepared and its characteristics discussed as well. Titanium electrodes were anodized in DMSO organic solution by applying DC voltages (6V~160V) to form various titanium oxide thin films. The dry (stored in dry air) anodized titanium electrode has a super-Nernstian response with a slope of 66.0 mV/pH unit, and the wet (stored in 4M KCl solution) anodized titanium electrode has a near Nernstian response with a slope of 59.0 mV/pH unit. Responses over a pH range 2 ~ 12 are linear. A self-assembled Prussian blue (PB) on titanium microelectrode with modified Nafion is described. The modified electrode showed high sensitivity when used in the determination of potassium ion concentration. It can effectively eliminate the interference of H+ ion after coated PB with modified Nafion. This electrode can be used in the determination of the time since death (postmortem interval, PMI).
author Chi-Chum Yang
楊啟全
spellingShingle Chi-Chum Yang
楊啟全
Studies of Modified Titanium oxide Electrodes
author_facet Chi-Chum Yang
楊啟全
author_sort Chi-Chum Yang
title Studies of Modified Titanium oxide Electrodes
title_short Studies of Modified Titanium oxide Electrodes
title_full Studies of Modified Titanium oxide Electrodes
title_fullStr Studies of Modified Titanium oxide Electrodes
title_full_unstemmed Studies of Modified Titanium oxide Electrodes
title_sort studies of modified titanium oxide electrodes
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/nq86x6
work_keys_str_mv AT chichumyang studiesofmodifiedtitaniumoxideelectrodes
AT yángqǐquán studiesofmodifiedtitaniumoxideelectrodes
AT chichumyang yǎnghuàtàixiūshìdiànjídeyánjiū
AT yángqǐquán yǎnghuàtàixiūshìdiànjídeyánjiū
_version_ 1719256854281846784