Design and Analysis of Normal Force Sensor of Connectors
碩士 === 國立臺灣科技大學 === 機械工程系 === 94 === Measuring the normal force of a connector is very important. The normal force of a connector needs to be above 100 gf, so the transmission of the signal can remain stable. In general, measuring the normal force of a connector needs to remove part of the plastic h...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/4j9vn9 |
id |
ndltd-TW-094NTUS5489104 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094NTUS54891042019-05-15T19:18:15Z http://ndltd.ncl.edu.tw/handle/4j9vn9 Design and Analysis of Normal Force Sensor of Connectors 連接器挾持力感測器設計與分析 Wen-hui Chaing 蔣文暉 碩士 國立臺灣科技大學 機械工程系 94 Measuring the normal force of a connector is very important. The normal force of a connector needs to be above 100 gf, so the transmission of the signal can remain stable. In general, measuring the normal force of a connector needs to remove part of the plastic housing and structure of a connector, so that the probe can be inserted into the connector to measure the normal force. Because the structure of the connector has been changed, the measurement results may be inaccurate. In the study, we use ANSYS software to design better spring element of a minature force sensor, and then fabricate it by MEMS technology. The miniature force sensor will be packaged with a PCB so that it can be employed to measure the normal force of the connector directly without destructing the structure of the connector. It is found that the effect of rectangular thin film is better than square thin film in terms of maximizing the measuring signal. Wei-chen Lee 李維楨 2006 學位論文 ; thesis 110 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 機械工程系 === 94 === Measuring the normal force of a connector is very important. The normal force of a connector needs to be above 100 gf, so the transmission of the signal can remain stable. In general, measuring the normal force of a connector needs to remove part of the plastic housing and structure of a connector, so that the probe can be inserted into the connector to measure the normal force. Because the structure of the connector has been changed, the measurement results may be inaccurate. In the study, we use ANSYS software to design better spring element of a minature force sensor, and then fabricate it by MEMS technology. The miniature force sensor will be packaged with a PCB so that it can be employed to measure the normal force of the connector directly without destructing the structure of the connector. It is found that the effect of rectangular thin film is better than square thin film in terms of maximizing the measuring signal.
|
author2 |
Wei-chen Lee |
author_facet |
Wei-chen Lee Wen-hui Chaing 蔣文暉 |
author |
Wen-hui Chaing 蔣文暉 |
spellingShingle |
Wen-hui Chaing 蔣文暉 Design and Analysis of Normal Force Sensor of Connectors |
author_sort |
Wen-hui Chaing |
title |
Design and Analysis of Normal Force Sensor of Connectors |
title_short |
Design and Analysis of Normal Force Sensor of Connectors |
title_full |
Design and Analysis of Normal Force Sensor of Connectors |
title_fullStr |
Design and Analysis of Normal Force Sensor of Connectors |
title_full_unstemmed |
Design and Analysis of Normal Force Sensor of Connectors |
title_sort |
design and analysis of normal force sensor of connectors |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/4j9vn9 |
work_keys_str_mv |
AT wenhuichaing designandanalysisofnormalforcesensorofconnectors AT jiǎngwénhuī designandanalysisofnormalforcesensorofconnectors AT wenhuichaing liánjiēqìxiéchílìgǎncèqìshèjìyǔfēnxī AT jiǎngwénhuī liánjiēqìxiéchílìgǎncèqìshèjìyǔfēnxī |
_version_ |
1719087400692482048 |