Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices

碩士 === 國立臺灣大學 === 土木工程學研究所 === 94 === Post-tensioned (PT) steel beam to column connection constructed with friction devices (FDs) combines the characteristics of pre-stressed strands and frictional energy dissipating devices. Thus, the post-tensioned system possesses re-centering capability from the...

Full description

Bibliographic Details
Main Authors: Chin-Lung Lin, 林錦隆
Other Authors: 蔡克銓
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/59800450473536392036
id ndltd-TW-094NTU05015108
record_format oai_dc
spelling ndltd-TW-094NTU050151082015-12-16T04:38:37Z http://ndltd.ncl.edu.tw/handle/59800450473536392036 Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices 鋼造含摩擦型消能裝置預力梁柱接頭之耐震行為研究 Chin-Lung Lin 林錦隆 碩士 國立臺灣大學 土木工程學研究所 94 Post-tensioned (PT) steel beam to column connection constructed with friction devices (FDs) combines the characteristics of pre-stressed strands and frictional energy dissipating devices. Thus, the post-tensioned system possesses re-centering capability from the pre-stressed strands while dissipating seismic energy in the beam web friction devices. This paper first derives the force-deformation relationships of the post-tensioned steel beam to column connection constructed with bolted web friction devices. The paper then describes the test program conducted in the National Center for Research on Earthquake Engineering on four bolted friction devices and four full-scale PT beam-to-column moment connection subassemblies. Tests confirm that (1) hysteretic behavior of four bolted friction devices is very stable, and the friction coefficient between the steel plate and the brass shim is about 0.34, (2) the proposed force-deformation relationships accurately predict the experimental responses of the PT connections under cyclically increasing deformations up to a peak beam rotation of 0.05 radians, (3) the PT connection using the FDs can be designed with a higher decompression moment than those using other type of metallic yielding energy-dissipating devices, (4) the decompression moments do not degrade as beam cyclic deformations increase. The paper concludes with the design recommendations for self-centering moment connections using friction devices. 蔡克銓 2006 學位論文 ; thesis 118 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 土木工程學研究所 === 94 === Post-tensioned (PT) steel beam to column connection constructed with friction devices (FDs) combines the characteristics of pre-stressed strands and frictional energy dissipating devices. Thus, the post-tensioned system possesses re-centering capability from the pre-stressed strands while dissipating seismic energy in the beam web friction devices. This paper first derives the force-deformation relationships of the post-tensioned steel beam to column connection constructed with bolted web friction devices. The paper then describes the test program conducted in the National Center for Research on Earthquake Engineering on four bolted friction devices and four full-scale PT beam-to-column moment connection subassemblies. Tests confirm that (1) hysteretic behavior of four bolted friction devices is very stable, and the friction coefficient between the steel plate and the brass shim is about 0.34, (2) the proposed force-deformation relationships accurately predict the experimental responses of the PT connections under cyclically increasing deformations up to a peak beam rotation of 0.05 radians, (3) the PT connection using the FDs can be designed with a higher decompression moment than those using other type of metallic yielding energy-dissipating devices, (4) the decompression moments do not degrade as beam cyclic deformations increase. The paper concludes with the design recommendations for self-centering moment connections using friction devices.
author2 蔡克銓
author_facet 蔡克銓
Chin-Lung Lin
林錦隆
author Chin-Lung Lin
林錦隆
spellingShingle Chin-Lung Lin
林錦隆
Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices
author_sort Chin-Lung Lin
title Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices
title_short Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices
title_full Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices
title_fullStr Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices
title_full_unstemmed Seismic Behavior of Post-tensioned Steel Beam to Column Connection with Friction Devices
title_sort seismic behavior of post-tensioned steel beam to column connection with friction devices
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/59800450473536392036
work_keys_str_mv AT chinlunglin seismicbehaviorofposttensionedsteelbeamtocolumnconnectionwithfrictiondevices
AT línjǐnlóng seismicbehaviorofposttensionedsteelbeamtocolumnconnectionwithfrictiondevices
AT chinlunglin gāngzàohánmócāxíngxiāonéngzhuāngzhìyùlìliángzhùjiētóuzhīnàizhènxíngwèiyánjiū
AT línjǐnlóng gāngzàohánmócāxíngxiāonéngzhuāngzhìyùlìliángzhùjiētóuzhīnàizhènxíngwèiyánjiū
_version_ 1718150016712835072