Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities

碩士 === 國立清華大學 === 物理學系 === 94 === This thesis dealt with two research topics, one relating to x-ray waveguides, the other to multiplate x-ray cavities. For the former a given incident x-ray beam is usually coupled into a waveguide from the side or from the front at grazing or normal incidence condi...

Full description

Bibliographic Details
Main Authors: Po-Wei Wu, 武柏瑋
Other Authors: Shih-Lin Chang
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/09704881581098912252
id ndltd-TW-094NTHU5198048
record_format oai_dc
spelling ndltd-TW-094NTHU51980482015-12-16T04:39:23Z http://ndltd.ncl.edu.tw/handle/09704881581098912252 Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities 廣角入射X光波導管之垂直波導效應以及多片X光共振腔之研究 Po-Wei Wu 武柏瑋 碩士 國立清華大學 物理學系 94 This thesis dealt with two research topics, one relating to x-ray waveguides, the other to multiplate x-ray cavities. For the former a given incident x-ray beam is usually coupled into a waveguide from the side or from the front at grazing or normal incidence condition. In contrast, here we propose to use surface diffraction beam of (1 1 3) reflection to guide x-rays in a wide angle incidence geometry. Waveguides of 150 μm in height, 2 cm in length and the width ranging from 5 to 100 μm were prepared from a 4-inch Si(001) crystal wafer by using the microelectronic lithography process, then plated with gold by thermal evaporation.Much more beams were collected in the waveguide because of total reflection. Second part is concerned with simulation of resonance in multiplate x-ray cavities. We have experimentally observed cavity resonance fringes in the Fabry-Perot resonators for hard x-rays, but at the same time try to simulate energy scans of cavities with different numbers of plates according to the x-ray dynamical theory, while energy spread of the incident beam is notionally gaussian distribution. We attempted to find out the meaning of Fourier transform, comparison between different numbers of plates, and effects on changing gap width of multiplate cavities. Shih-Lin Chang 張石麟 2006 學位論文 ; thesis 61 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 物理學系 === 94 === This thesis dealt with two research topics, one relating to x-ray waveguides, the other to multiplate x-ray cavities. For the former a given incident x-ray beam is usually coupled into a waveguide from the side or from the front at grazing or normal incidence condition. In contrast, here we propose to use surface diffraction beam of (1 1 3) reflection to guide x-rays in a wide angle incidence geometry. Waveguides of 150 μm in height, 2 cm in length and the width ranging from 5 to 100 μm were prepared from a 4-inch Si(001) crystal wafer by using the microelectronic lithography process, then plated with gold by thermal evaporation.Much more beams were collected in the waveguide because of total reflection. Second part is concerned with simulation of resonance in multiplate x-ray cavities. We have experimentally observed cavity resonance fringes in the Fabry-Perot resonators for hard x-rays, but at the same time try to simulate energy scans of cavities with different numbers of plates according to the x-ray dynamical theory, while energy spread of the incident beam is notionally gaussian distribution. We attempted to find out the meaning of Fourier transform, comparison between different numbers of plates, and effects on changing gap width of multiplate cavities.
author2 Shih-Lin Chang
author_facet Shih-Lin Chang
Po-Wei Wu
武柏瑋
author Po-Wei Wu
武柏瑋
spellingShingle Po-Wei Wu
武柏瑋
Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
author_sort Po-Wei Wu
title Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
title_short Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
title_full Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
title_fullStr Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
title_full_unstemmed Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
title_sort beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/09704881581098912252
work_keys_str_mv AT poweiwu beamcompressioninwideangleincidentxraywaveguidesandresonanceinmultiplatexraycavities
AT wǔbǎiwěi beamcompressioninwideangleincidentxraywaveguidesandresonanceinmultiplatexraycavities
AT poweiwu guǎngjiǎorùshèxguāngbōdǎoguǎnzhīchuízhíbōdǎoxiàoyīngyǐjíduōpiànxguānggòngzhènqiāngzhīyánjiū
AT wǔbǎiwěi guǎngjiǎorùshèxguāngbōdǎoguǎnzhīchuízhíbōdǎoxiàoyīngyǐjíduōpiànxguānggòngzhènqiāngzhīyánjiū
_version_ 1718152002524938240