Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities
碩士 === 國立清華大學 === 物理學系 === 94 === This thesis dealt with two research topics, one relating to x-ray waveguides, the other to multiplate x-ray cavities. For the former a given incident x-ray beam is usually coupled into a waveguide from the side or from the front at grazing or normal incidence condi...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/09704881581098912252 |
id |
ndltd-TW-094NTHU5198048 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094NTHU51980482015-12-16T04:39:23Z http://ndltd.ncl.edu.tw/handle/09704881581098912252 Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities 廣角入射X光波導管之垂直波導效應以及多片X光共振腔之研究 Po-Wei Wu 武柏瑋 碩士 國立清華大學 物理學系 94 This thesis dealt with two research topics, one relating to x-ray waveguides, the other to multiplate x-ray cavities. For the former a given incident x-ray beam is usually coupled into a waveguide from the side or from the front at grazing or normal incidence condition. In contrast, here we propose to use surface diffraction beam of (1 1 3) reflection to guide x-rays in a wide angle incidence geometry. Waveguides of 150 μm in height, 2 cm in length and the width ranging from 5 to 100 μm were prepared from a 4-inch Si(001) crystal wafer by using the microelectronic lithography process, then plated with gold by thermal evaporation.Much more beams were collected in the waveguide because of total reflection. Second part is concerned with simulation of resonance in multiplate x-ray cavities. We have experimentally observed cavity resonance fringes in the Fabry-Perot resonators for hard x-rays, but at the same time try to simulate energy scans of cavities with different numbers of plates according to the x-ray dynamical theory, while energy spread of the incident beam is notionally gaussian distribution. We attempted to find out the meaning of Fourier transform, comparison between different numbers of plates, and effects on changing gap width of multiplate cavities. Shih-Lin Chang 張石麟 2006 學位論文 ; thesis 61 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立清華大學 === 物理學系 === 94 === This thesis dealt with two research topics, one relating to x-ray waveguides, the other to multiplate x-ray cavities.
For the former a given incident x-ray beam is usually coupled into a waveguide from the side or from the front at grazing or normal incidence condition. In contrast, here we propose to use surface diffraction beam of (1 1 3) reflection to guide x-rays in a wide angle incidence geometry. Waveguides of 150 μm in height, 2 cm in length and the width ranging from 5 to 100 μm were prepared from a 4-inch Si(001) crystal wafer by using the microelectronic lithography process, then plated with gold by thermal evaporation.Much more beams were collected in the waveguide
because of total reflection.
Second part is concerned with simulation of resonance in multiplate x-ray cavities. We have experimentally observed cavity resonance fringes in the Fabry-Perot resonators for hard x-rays, but at the same time try to simulate energy scans of cavities with different numbers of plates according to the x-ray dynamical theory, while energy spread of the incident beam is notionally gaussian distribution. We attempted to find out the meaning of Fourier transform, comparison between different numbers of plates, and effects on changing gap width of multiplate cavities.
|
author2 |
Shih-Lin Chang |
author_facet |
Shih-Lin Chang Po-Wei Wu 武柏瑋 |
author |
Po-Wei Wu 武柏瑋 |
spellingShingle |
Po-Wei Wu 武柏瑋 Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
author_sort |
Po-Wei Wu |
title |
Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
title_short |
Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
title_full |
Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
title_fullStr |
Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
title_full_unstemmed |
Beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
title_sort |
beam compression in wide-angle incident x-ray waveguides and resonance in multiplate x-ray cavities |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/09704881581098912252 |
work_keys_str_mv |
AT poweiwu beamcompressioninwideangleincidentxraywaveguidesandresonanceinmultiplatexraycavities AT wǔbǎiwěi beamcompressioninwideangleincidentxraywaveguidesandresonanceinmultiplatexraycavities AT poweiwu guǎngjiǎorùshèxguāngbōdǎoguǎnzhīchuízhíbōdǎoxiàoyīngyǐjíduōpiànxguānggòngzhènqiāngzhīyánjiū AT wǔbǎiwěi guǎngjiǎorùshèxguāngbōdǎoguǎnzhīchuízhíbōdǎoxiàoyīngyǐjíduōpiànxguānggòngzhènqiāngzhīyánjiū |
_version_ |
1718152002524938240 |