A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects
碩士 === 國立中山大學 === 生物醫學科學研究所 === 94 === Abstract: Background: At present, device closure of interatrial communication has become a well established technique in order to adequately treat severe left-to-right shunt associated with ASDs. During the traditional procedure, fluoroscopy with the waist of a...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/17096215601466647204 |
id |
ndltd-TW-094NSYS5114002 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094NSYS51140022016-05-27T04:18:57Z http://ndltd.ncl.edu.tw/handle/17096215601466647204 A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects 在第二型心房中膈缺損的病患作心導管關閉術時應用經胸心臟超音波為一種非侵襲性的測量方法用以選取合適的閉合器 Kuang-Jen Chien 簡光仁 碩士 國立中山大學 生物醫學科學研究所 94 Abstract: Background: At present, device closure of interatrial communication has become a well established technique in order to adequately treat severe left-to-right shunt associated with ASDs. During the traditional procedure, fluoroscopy with the waist of a compliant balloon is used to determine the appropriate size of the closure device and defect sizing. Choice of adequate closure device using transthoracic echocardiography (TTE) has been hitherto unreported. Methods & Materials: Between December 2002 and October 2004, 40 patients (15 males, 25 females, mean age; 11.7 ± 7.8 years ) with secundum ASDs underwent transcatheter closure at our institution. In group 1, 30 patients had the procedure by balloon sizing and TTE sizing. In 10 patients (group 2), TTE sizing was used as the sole too l for selecting device size and the device size was chosen to be based on the Amplatzer septal occluder ( ASO ) size and TTE size ratio in group 1. The procedure was performed under continuous transoesophageal echocardiographic monitor with general anesthesia. Results: The correlation was found between TTE and stretched balloon sizing diameter SBD ( y= 1.2645x-1.4465; R²=0.9861 ), and between TTE size and ASO size ( y = 1.3412x-1.2864; R²=0.9929 ) in group 1. In group 2, statistical correlation between TTE and ASO ( y=1.3419x-0.1172; R²=0.9934 ) was also found. Good linear regression between TTE size and ASO chosen size was noted in group 1 and group 2 (R²=0.99).In group 2, successful device implantation was accomplished in all patients whose device size was chosen to be based on the ASO and TTE ratio in group 1. Conclusions: TTE sizing is a safe and ideal method to measure interatrial defect and choose the occluding device respectively. With our experience, the sizing based on the TTE is generally easier than measurement from the balloon sizing. Cheng-Liang Lee 李正亮 2006 學位論文 ; thesis 51 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中山大學 === 生物醫學科學研究所 === 94 === Abstract:
Background: At present, device closure of interatrial communication has become a well established technique in order to adequately treat severe left-to-right shunt associated with ASDs. During the traditional procedure, fluoroscopy with the waist of a compliant balloon is used to determine the appropriate size of the closure device and defect sizing. Choice of adequate closure device using transthoracic echocardiography (TTE) has been hitherto unreported.
Methods & Materials: Between December 2002 and October 2004, 40 patients (15 males, 25 females, mean age; 11.7 ± 7.8 years ) with secundum ASDs underwent transcatheter closure at our institution. In group 1, 30 patients had the procedure by balloon sizing and TTE sizing. In 10 patients (group 2), TTE sizing was used as the sole too l for selecting device size and the device size was chosen to be based on the Amplatzer septal occluder ( ASO ) size and TTE size ratio in group 1. The procedure was performed under continuous transoesophageal echocardiographic monitor with general anesthesia.
Results: The correlation was found between TTE and stretched balloon sizing diameter SBD ( y= 1.2645x-1.4465; R²=0.9861 ), and between TTE size and ASO size ( y = 1.3412x-1.2864; R²=0.9929 ) in group 1. In group 2, statistical correlation between TTE and ASO ( y=1.3419x-0.1172; R²=0.9934 ) was also found. Good linear regression between TTE size and ASO chosen size was noted in group 1 and group 2 (R²=0.99).In group 2, successful device implantation was accomplished in all patients whose device size was chosen to be based on the ASO and TTE ratio in group 1.
Conclusions: TTE sizing is a safe and ideal method to measure interatrial defect and choose the occluding device respectively. With our experience, the sizing based on the TTE is generally easier than measurement from the balloon sizing.
|
author2 |
Cheng-Liang Lee |
author_facet |
Cheng-Liang Lee Kuang-Jen Chien 簡光仁 |
author |
Kuang-Jen Chien 簡光仁 |
spellingShingle |
Kuang-Jen Chien 簡光仁 A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects |
author_sort |
Kuang-Jen Chien |
title |
A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects |
title_short |
A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects |
title_full |
A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects |
title_fullStr |
A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects |
title_full_unstemmed |
A Noninvasive Sizing Method to Choose Fitted Amplatzer Septal Occluder by Transthoracic Echocardiography in Patients with Secundum Atrial Septal Defects |
title_sort |
noninvasive sizing method to choose fitted amplatzer septal occluder by transthoracic echocardiography in patients with secundum atrial septal defects |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/17096215601466647204 |
work_keys_str_mv |
AT kuangjenchien anoninvasivesizingmethodtochoosefittedamplatzerseptaloccluderbytransthoracicechocardiographyinpatientswithsecundumatrialseptaldefects AT jiǎnguāngrén anoninvasivesizingmethodtochoosefittedamplatzerseptaloccluderbytransthoracicechocardiographyinpatientswithsecundumatrialseptaldefects AT kuangjenchien zàidìèrxíngxīnfángzhōnggéquēsǔndebìnghuànzuòxīndǎoguǎnguānbìshùshíyīngyòngjīngxiōngxīnzàngchāoyīnbōwèiyīzhǒngfēiqīnxíxìngdecèliàngfāngfǎyòngyǐxuǎnqǔhéshìdebìhéqì AT jiǎnguāngrén zàidìèrxíngxīnfángzhōnggéquēsǔndebìnghuànzuòxīndǎoguǎnguānbìshùshíyīngyòngjīngxiōngxīnzàngchāoyīnbōwèiyīzhǒngfēiqīnxíxìngdecèliàngfāngfǎyòngyǐxuǎnqǔhéshìdebìhéqì AT kuangjenchien noninvasivesizingmethodtochoosefittedamplatzerseptaloccluderbytransthoracicechocardiographyinpatientswithsecundumatrialseptaldefects AT jiǎnguāngrén noninvasivesizingmethodtochoosefittedamplatzerseptaloccluderbytransthoracicechocardiographyinpatientswithsecundumatrialseptaldefects |
_version_ |
1718283646086938624 |