Implementation of a Portable Ultrasound Densitometry System

碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 94 ===   Since osteoporosis is common disease for old people, it can only examine by expensive instrument in hospital, such as dual-energy X-ray absorptiometry (DEXA) and ultrasound densitometry system in hospital for evaluating the degree of osteoporosis. The purpo...

Full description

Bibliographic Details
Main Authors: Ming-Yueh Hsu, 徐鳴嶽
Other Authors: Tain _Song Chen
Format: Others
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/41535132192332843839
id ndltd-TW-094NCKU5530035
record_format oai_dc
spelling ndltd-TW-094NCKU55300352015-12-16T04:31:52Z http://ndltd.ncl.edu.tw/handle/41535132192332843839 Implementation of a Portable Ultrasound Densitometry System 建立可攜式超音波骨密度量測系統 Ming-Yueh Hsu 徐鳴嶽 碩士 國立成功大學 醫學工程研究所碩博士班 94   Since osteoporosis is common disease for old people, it can only examine by expensive instrument in hospital, such as dual-energy X-ray absorptiometry (DEXA) and ultrasound densitometry system in hospital for evaluating the degree of osteoporosis. The purpose of this research is implementation of a portable ultrasound densitometry system. Two kinds of BUA parameter and SOS parameter by ultrasound measurement diagnose the osteoporosis degree.   The design of this research is divided into hardware and software. The hardware has four parts: (1) Pulser: using MOSFET as switch to generate the pulse. (2) Receiver: using the low noise, low distortion operational amplifier (TL071), and the high performance video operational amplifier (AD811) to receive ultrasound signal. (3) Controller: single chip (8051) control the hardware; (4) DAQ: acquire ultrasound signal and store data in RAM. The software has two parts: (1) writing the assemble language on Controller (8051) for controlling the hardware; (2) operation interface for with SOS and BUA function using for Visual Basic.   In this result, we have finished the system of ultrasonic Pulser/Receiver (300V) which can be sampled at 15MHz in DAQ part. In SOS measurement, errors are all less than 2.1% when utilize this system to test phantom and calcaneum. In BUA measurement, we can distinguish normal bone phantom and osteoporosis bone phantom; but the examination for calcaneum is not confirmed whether our system can differentiate the osteoporosis effectively. Tain _Song Chen 陳天送 學位論文 ; thesis 66 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 94 ===   Since osteoporosis is common disease for old people, it can only examine by expensive instrument in hospital, such as dual-energy X-ray absorptiometry (DEXA) and ultrasound densitometry system in hospital for evaluating the degree of osteoporosis. The purpose of this research is implementation of a portable ultrasound densitometry system. Two kinds of BUA parameter and SOS parameter by ultrasound measurement diagnose the osteoporosis degree.   The design of this research is divided into hardware and software. The hardware has four parts: (1) Pulser: using MOSFET as switch to generate the pulse. (2) Receiver: using the low noise, low distortion operational amplifier (TL071), and the high performance video operational amplifier (AD811) to receive ultrasound signal. (3) Controller: single chip (8051) control the hardware; (4) DAQ: acquire ultrasound signal and store data in RAM. The software has two parts: (1) writing the assemble language on Controller (8051) for controlling the hardware; (2) operation interface for with SOS and BUA function using for Visual Basic.   In this result, we have finished the system of ultrasonic Pulser/Receiver (300V) which can be sampled at 15MHz in DAQ part. In SOS measurement, errors are all less than 2.1% when utilize this system to test phantom and calcaneum. In BUA measurement, we can distinguish normal bone phantom and osteoporosis bone phantom; but the examination for calcaneum is not confirmed whether our system can differentiate the osteoporosis effectively.
author2 Tain _Song Chen
author_facet Tain _Song Chen
Ming-Yueh Hsu
徐鳴嶽
author Ming-Yueh Hsu
徐鳴嶽
spellingShingle Ming-Yueh Hsu
徐鳴嶽
Implementation of a Portable Ultrasound Densitometry System
author_sort Ming-Yueh Hsu
title Implementation of a Portable Ultrasound Densitometry System
title_short Implementation of a Portable Ultrasound Densitometry System
title_full Implementation of a Portable Ultrasound Densitometry System
title_fullStr Implementation of a Portable Ultrasound Densitometry System
title_full_unstemmed Implementation of a Portable Ultrasound Densitometry System
title_sort implementation of a portable ultrasound densitometry system
url http://ndltd.ncl.edu.tw/handle/41535132192332843839
work_keys_str_mv AT mingyuehhsu implementationofaportableultrasounddensitometrysystem
AT xúmíngyuè implementationofaportableultrasounddensitometrysystem
AT mingyuehhsu jiànlìkěxiéshìchāoyīnbōgǔmìdùliàngcèxìtǒng
AT xúmíngyuè jiànlìkěxiéshìchāoyīnbōgǔmìdùliàngcèxìtǒng
_version_ 1718149218792636416