Solving Base-Line Drift Problem by Multi-Stage Sampling Method

碩士 === 逢甲大學 === 通訊工程所 === 94 === Intelligent clothing or smart clothe integrate biological signal sensor, wireless data transferring modules, PC analytical software and power supply unit together for continuously monitoring patient’s medical conditions. A typical example would be an intelligent clot...

Full description

Bibliographic Details
Main Authors: Chia-Yu Jan, 冉家瑜
Other Authors: Hsiao-Chiu Chu
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/54963334747530275142
id ndltd-TW-094FCU05650005
record_format oai_dc
spelling ndltd-TW-094FCU056500052015-12-11T04:04:18Z http://ndltd.ncl.edu.tw/handle/54963334747530275142 Solving Base-Line Drift Problem by Multi-Stage Sampling Method 利用多段取樣解決基線漂移問題 Chia-Yu Jan 冉家瑜 碩士 逢甲大學 通訊工程所 94 Intelligent clothing or smart clothe integrate biological signal sensor, wireless data transferring modules, PC analytical software and power supply unit together for continuously monitoring patient’s medical conditions. A typical example would be an intelligent clothing with the functions of ECG (Electrocardiogram) monitoring. To resolve base line drifting problem, several alternatives were examined. We have utilized multiple segment sampling methodology to enhance user’s mobility. Temperature control function was also added to enhance user’s comfort. Wireless bluetooth technology for data transmission was used to improve the ease of patient who either need intermittently or long term biological signal monitoring. Hsiao-Chiu Chu 朱嘯秋 2006 學位論文 ; thesis 65 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 逢甲大學 === 通訊工程所 === 94 === Intelligent clothing or smart clothe integrate biological signal sensor, wireless data transferring modules, PC analytical software and power supply unit together for continuously monitoring patient’s medical conditions. A typical example would be an intelligent clothing with the functions of ECG (Electrocardiogram) monitoring. To resolve base line drifting problem, several alternatives were examined. We have utilized multiple segment sampling methodology to enhance user’s mobility. Temperature control function was also added to enhance user’s comfort. Wireless bluetooth technology for data transmission was used to improve the ease of patient who either need intermittently or long term biological signal monitoring.
author2 Hsiao-Chiu Chu
author_facet Hsiao-Chiu Chu
Chia-Yu Jan
冉家瑜
author Chia-Yu Jan
冉家瑜
spellingShingle Chia-Yu Jan
冉家瑜
Solving Base-Line Drift Problem by Multi-Stage Sampling Method
author_sort Chia-Yu Jan
title Solving Base-Line Drift Problem by Multi-Stage Sampling Method
title_short Solving Base-Line Drift Problem by Multi-Stage Sampling Method
title_full Solving Base-Line Drift Problem by Multi-Stage Sampling Method
title_fullStr Solving Base-Line Drift Problem by Multi-Stage Sampling Method
title_full_unstemmed Solving Base-Line Drift Problem by Multi-Stage Sampling Method
title_sort solving base-line drift problem by multi-stage sampling method
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/54963334747530275142
work_keys_str_mv AT chiayujan solvingbaselinedriftproblembymultistagesamplingmethod
AT rǎnjiāyú solvingbaselinedriftproblembymultistagesamplingmethod
AT chiayujan lìyòngduōduànqǔyàngjiějuéjīxiànpiàoyíwèntí
AT rǎnjiāyú lìyòngduōduànqǔyàngjiějuéjīxiànpiàoyíwèntí
_version_ 1718147730891603968