An Analysis of Transient of Transmission Lines Caused by a Lightning Strike

碩士 === 逢甲大學 === 電機工程所 === 94 === The purpose of this study was to analyze the transient phenomena of transmission lines and towers with and without line arresters caused by lightning strokes, through which the specifications of structure design were modified in order to improve the reliability of po...

Full description

Bibliographic Details
Main Authors: Chih-Min Huang, 黃志民
Other Authors: Sy-Ruen Huang
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/33814087254190881017
id ndltd-TW-094FCU05442021
record_format oai_dc
spelling ndltd-TW-094FCU054420212015-12-11T04:04:28Z http://ndltd.ncl.edu.tw/handle/33814087254190881017 An Analysis of Transient of Transmission Lines Caused by a Lightning Strike 雷擊輸電線引起暫態分析與探討 Chih-Min Huang 黃志民 碩士 逢甲大學 電機工程所 94 The purpose of this study was to analyze the transient phenomena of transmission lines and towers with and without line arresters caused by lightning strokes, through which the specifications of structure design were modified in order to improve the reliability of power transmission. From this premise, by using ATP Draw model, three power configuration modes of the 345kv overhead transmission lines and towers were simulated and analyzed: (1) The four phases JMarti transmission line module (applied to overhead transmission lines with shields) joined the single phase distributive parameters Z module (used to simulate the field conditions of towers). (2) The single phase JMarti simulated for shield lines joined the single phase distributive parameters Z module for tower, and the three phases distributive parameters Z-T module for overhead transmission lines without shields. (3) The single phase distributive parameters Z module simulated for shield lines and towers joined the three phase distributive parameters Z-T modules for overhead transmission lines. In addition, the researcher sought to reply to other relevant modes set out in the literature to evaluate the present simulated conditions by way ofATP Draw. The results provided some evidence of the effectiveness of the aforementioned three modes. Sy-Ruen Huang 黃思倫 2006 學位論文 ; thesis 101 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 逢甲大學 === 電機工程所 === 94 === The purpose of this study was to analyze the transient phenomena of transmission lines and towers with and without line arresters caused by lightning strokes, through which the specifications of structure design were modified in order to improve the reliability of power transmission. From this premise, by using ATP Draw model, three power configuration modes of the 345kv overhead transmission lines and towers were simulated and analyzed: (1) The four phases JMarti transmission line module (applied to overhead transmission lines with shields) joined the single phase distributive parameters Z module (used to simulate the field conditions of towers). (2) The single phase JMarti simulated for shield lines joined the single phase distributive parameters Z module for tower, and the three phases distributive parameters Z-T module for overhead transmission lines without shields. (3) The single phase distributive parameters Z module simulated for shield lines and towers joined the three phase distributive parameters Z-T modules for overhead transmission lines. In addition, the researcher sought to reply to other relevant modes set out in the literature to evaluate the present simulated conditions by way ofATP Draw. The results provided some evidence of the effectiveness of the aforementioned three modes.
author2 Sy-Ruen Huang
author_facet Sy-Ruen Huang
Chih-Min Huang
黃志民
author Chih-Min Huang
黃志民
spellingShingle Chih-Min Huang
黃志民
An Analysis of Transient of Transmission Lines Caused by a Lightning Strike
author_sort Chih-Min Huang
title An Analysis of Transient of Transmission Lines Caused by a Lightning Strike
title_short An Analysis of Transient of Transmission Lines Caused by a Lightning Strike
title_full An Analysis of Transient of Transmission Lines Caused by a Lightning Strike
title_fullStr An Analysis of Transient of Transmission Lines Caused by a Lightning Strike
title_full_unstemmed An Analysis of Transient of Transmission Lines Caused by a Lightning Strike
title_sort analysis of transient of transmission lines caused by a lightning strike
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/33814087254190881017
work_keys_str_mv AT chihminhuang ananalysisoftransientoftransmissionlinescausedbyalightningstrike
AT huángzhìmín ananalysisoftransientoftransmissionlinescausedbyalightningstrike
AT chihminhuang léijīshūdiànxiànyǐnqǐzàntàifēnxīyǔtàntǎo
AT huángzhìmín léijīshūdiànxiànyǐnqǐzàntàifēnxīyǔtàntǎo
AT chihminhuang analysisoftransientoftransmissionlinescausedbyalightningstrike
AT huángzhìmín analysisoftransientoftransmissionlinescausedbyalightningstrike
_version_ 1718147651847847936