Study of the Current Transformer Temperature Rise for Distribution Board

碩士 === 逢甲大學 === 資訊電機工程碩士在職專班 === 94 === Current is need to change from high current to low current by current transformer(CT) in Power system, that meter can examine and relay can detect directly. When the power system is normal the iron-core of CT magnetism saturation phenomenon is unlikely. When f...

Full description

Bibliographic Details
Main Authors: Yuan-Fu Chang, 張源富
Other Authors: Sy-Ruen Huang
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/58491649189254115547
id ndltd-TW-094FCU05392082
record_format oai_dc
spelling ndltd-TW-094FCU053920822015-12-11T04:04:28Z http://ndltd.ncl.edu.tw/handle/58491649189254115547 Study of the Current Transformer Temperature Rise for Distribution Board 配電盤內的比流器溫昇之研究 Yuan-Fu Chang 張源富 碩士 逢甲大學 資訊電機工程碩士在職專班 94 Current is need to change from high current to low current by current transformer(CT) in Power system, that meter can examine and relay can detect directly. When the power system is normal the iron-core of CT magnetism saturation phenomenon is unlikely. When faults occur on the power system. However, CT may saturation due to the malfunctions of power systems because of the property of iron-core of CT is non-linearity once CT had saturated, the exciting current of CT would be huge and the secondary current would be distorting. The thesis draft finite element method to analyze. First reality locale measure results in base. Furthermore, unidentical seat of CT in distribution board compare and analyze electric field, magnetic field and temperature distributions within the device to understand relative relation of electric field, magnetic field and temperature to confirm the cause of iron-core of CT magnetism saturation. Sy-Ruen Huang 黃思倫 2006 學位論文 ; thesis 72 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 逢甲大學 === 資訊電機工程碩士在職專班 === 94 === Current is need to change from high current to low current by current transformer(CT) in Power system, that meter can examine and relay can detect directly. When the power system is normal the iron-core of CT magnetism saturation phenomenon is unlikely. When faults occur on the power system. However, CT may saturation due to the malfunctions of power systems because of the property of iron-core of CT is non-linearity once CT had saturated, the exciting current of CT would be huge and the secondary current would be distorting. The thesis draft finite element method to analyze. First reality locale measure results in base. Furthermore, unidentical seat of CT in distribution board compare and analyze electric field, magnetic field and temperature distributions within the device to understand relative relation of electric field, magnetic field and temperature to confirm the cause of iron-core of CT magnetism saturation.
author2 Sy-Ruen Huang
author_facet Sy-Ruen Huang
Yuan-Fu Chang
張源富
author Yuan-Fu Chang
張源富
spellingShingle Yuan-Fu Chang
張源富
Study of the Current Transformer Temperature Rise for Distribution Board
author_sort Yuan-Fu Chang
title Study of the Current Transformer Temperature Rise for Distribution Board
title_short Study of the Current Transformer Temperature Rise for Distribution Board
title_full Study of the Current Transformer Temperature Rise for Distribution Board
title_fullStr Study of the Current Transformer Temperature Rise for Distribution Board
title_full_unstemmed Study of the Current Transformer Temperature Rise for Distribution Board
title_sort study of the current transformer temperature rise for distribution board
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/58491649189254115547
work_keys_str_mv AT yuanfuchang studyofthecurrenttransformertemperaturerisefordistributionboard
AT zhāngyuánfù studyofthecurrenttransformertemperaturerisefordistributionboard
AT yuanfuchang pèidiànpánnèidebǐliúqìwēnshēngzhīyánjiū
AT zhāngyuánfù pèidiànpánnèidebǐliúqìwēnshēngzhīyánjiū
_version_ 1718147609926828032