Parameter determination of infrared thermography toward the inspection of concrete surfaces after fire exposure

碩士 === 朝陽科技大學 === 營建工程系碩士班 === 94 === The objective of current study is to explore the feasibility of post-fire assessment of concrete surface using infrared thermography, or IRT. Fire exposure of concrete specimens was simulated using electric ovens at different temperatures lasting for two hours....

Full description

Bibliographic Details
Main Authors: Chou-Hsuan Lee, 李洲亘
Other Authors: Chih-Hung Chiang
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/83rh9z
Description
Summary:碩士 === 朝陽科技大學 === 營建工程系碩士班 === 94 === The objective of current study is to explore the feasibility of post-fire assessment of concrete surface using infrared thermography, or IRT. Fire exposure of concrete specimens was simulated using electric ovens at different temperatures lasting for two hours. Uniform heat flux was applied to the surface of the specimen after cooling to room temperature. The thermal images were then taken immediately following the heat flux was terminated. In some cases, surface cracks may be associated with the area of higher temperature in thermal images. Similar results were found based on two- and three-dimensional modeling using finite element analysis. Furthermore, the effect of concrete surface emissivity on the thermal images was also investigated.