The Performance-Based Design of Sprinklers System in Hospital
碩士 === 長榮大學 === 職業安全與衛生學系碩士班 === 94 === These researches evaluated the fire protection systems in hospital and proceed a performance-based design for sprinkler system. The scope was too broad to cover every area in hospital. The sprinkler system was chosen to be the first evaluation item for hospita...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/33694485850671795232 |
id |
ndltd-TW-094CJU00590005 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094CJU005900052016-06-03T04:13:27Z http://ndltd.ncl.edu.tw/handle/33694485850671795232 The Performance-Based Design of Sprinklers System in Hospital 醫療院所自動灑水設備性能化設計之探討 Yu-jen Chen 陳佑任 碩士 長榮大學 職業安全與衛生學系碩士班 94 These researches evaluated the fire protection systems in hospital and proceed a performance-based design for sprinkler system. The scope was too broad to cover every area in hospital. The sprinkler system was chosen to be the first evaluation item for hospital by using Fire Dynamics Simulator (FDS). Sprinkler layout, Fire size, and its location had significant effects for sprinkler actuation. The sprinkler took longer to actuate when 500kW fire was under 30cm thick beam. The sprinkler was accelerated to activate, when 500kW fire was under a 30cm thick beam and the beam was 10cm or 20cm away from the ceiling. The beam effect was insignificant when the fire was 1500kW. If the fire origin was moved 1m horizontally away from the beam and there was no clearance between ceiling and beam, the sprinkler was hard to activate. There was no difference for sprinkler actuation time of 10cm or 20cm clearance between ceiling and beam. They are also the same response time as a free ceiling for the same fire size. 【key word】: performance-based design、CFD model、hospital San-ping Ho 何三平 2006 學位論文 ; thesis 83 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 長榮大學 === 職業安全與衛生學系碩士班 === 94 === These researches evaluated the fire protection systems in hospital and proceed a performance-based design for sprinkler system. The scope was too broad to cover every area in hospital. The sprinkler system was chosen to be the first evaluation item for hospital by using Fire Dynamics Simulator (FDS). Sprinkler layout, Fire size, and its location had significant effects for sprinkler actuation. The sprinkler took longer to actuate when 500kW fire was under 30cm thick beam. The sprinkler was accelerated to activate, when 500kW fire was under a 30cm thick beam and the beam was 10cm or 20cm away from the ceiling. The beam effect was insignificant when the fire was 1500kW. If the fire origin was moved 1m horizontally away from the beam and there was no clearance between ceiling and beam, the sprinkler was hard to activate. There was no difference for sprinkler actuation time of 10cm or 20cm clearance between ceiling and beam. They are also the same response time as a free ceiling for the same fire size.
【key word】: performance-based design、CFD model、hospital
|
author2 |
San-ping Ho |
author_facet |
San-ping Ho Yu-jen Chen 陳佑任 |
author |
Yu-jen Chen 陳佑任 |
spellingShingle |
Yu-jen Chen 陳佑任 The Performance-Based Design of Sprinklers System in Hospital |
author_sort |
Yu-jen Chen |
title |
The Performance-Based Design of Sprinklers System in Hospital |
title_short |
The Performance-Based Design of Sprinklers System in Hospital |
title_full |
The Performance-Based Design of Sprinklers System in Hospital |
title_fullStr |
The Performance-Based Design of Sprinklers System in Hospital |
title_full_unstemmed |
The Performance-Based Design of Sprinklers System in Hospital |
title_sort |
performance-based design of sprinklers system in hospital |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/33694485850671795232 |
work_keys_str_mv |
AT yujenchen theperformancebaseddesignofsprinklerssysteminhospital AT chényòurèn theperformancebaseddesignofsprinklerssysteminhospital AT yujenchen yīliáoyuànsuǒzìdòngsǎshuǐshèbèixìngnénghuàshèjìzhītàntǎo AT chényòurèn yīliáoyuànsuǒzìdòngsǎshuǐshèbèixìngnénghuàshèjìzhītàntǎo AT yujenchen performancebaseddesignofsprinklerssysteminhospital AT chényòurèn performancebaseddesignofsprinklerssysteminhospital |
_version_ |
1718292144306782208 |