The Performance-Based Design of Sprinklers System in Hospital

碩士 === 長榮大學 === 職業安全與衛生學系碩士班 === 94 === These researches evaluated the fire protection systems in hospital and proceed a performance-based design for sprinkler system. The scope was too broad to cover every area in hospital. The sprinkler system was chosen to be the first evaluation item for hospita...

Full description

Bibliographic Details
Main Authors: Yu-jen Chen, 陳佑任
Other Authors: San-ping Ho
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/33694485850671795232
id ndltd-TW-094CJU00590005
record_format oai_dc
spelling ndltd-TW-094CJU005900052016-06-03T04:13:27Z http://ndltd.ncl.edu.tw/handle/33694485850671795232 The Performance-Based Design of Sprinklers System in Hospital 醫療院所自動灑水設備性能化設計之探討 Yu-jen Chen 陳佑任 碩士 長榮大學 職業安全與衛生學系碩士班 94 These researches evaluated the fire protection systems in hospital and proceed a performance-based design for sprinkler system. The scope was too broad to cover every area in hospital. The sprinkler system was chosen to be the first evaluation item for hospital by using Fire Dynamics Simulator (FDS). Sprinkler layout, Fire size, and its location had significant effects for sprinkler actuation. The sprinkler took longer to actuate when 500kW fire was under 30cm thick beam. The sprinkler was accelerated to activate, when 500kW fire was under a 30cm thick beam and the beam was 10cm or 20cm away from the ceiling. The beam effect was insignificant when the fire was 1500kW. If the fire origin was moved 1m horizontally away from the beam and there was no clearance between ceiling and beam, the sprinkler was hard to activate. There was no difference for sprinkler actuation time of 10cm or 20cm clearance between ceiling and beam. They are also the same response time as a free ceiling for the same fire size. 【key word】: performance-based design、CFD model、hospital San-ping Ho 何三平 2006 學位論文 ; thesis 83 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 長榮大學 === 職業安全與衛生學系碩士班 === 94 === These researches evaluated the fire protection systems in hospital and proceed a performance-based design for sprinkler system. The scope was too broad to cover every area in hospital. The sprinkler system was chosen to be the first evaluation item for hospital by using Fire Dynamics Simulator (FDS). Sprinkler layout, Fire size, and its location had significant effects for sprinkler actuation. The sprinkler took longer to actuate when 500kW fire was under 30cm thick beam. The sprinkler was accelerated to activate, when 500kW fire was under a 30cm thick beam and the beam was 10cm or 20cm away from the ceiling. The beam effect was insignificant when the fire was 1500kW. If the fire origin was moved 1m horizontally away from the beam and there was no clearance between ceiling and beam, the sprinkler was hard to activate. There was no difference for sprinkler actuation time of 10cm or 20cm clearance between ceiling and beam. They are also the same response time as a free ceiling for the same fire size. 【key word】: performance-based design、CFD model、hospital
author2 San-ping Ho
author_facet San-ping Ho
Yu-jen Chen
陳佑任
author Yu-jen Chen
陳佑任
spellingShingle Yu-jen Chen
陳佑任
The Performance-Based Design of Sprinklers System in Hospital
author_sort Yu-jen Chen
title The Performance-Based Design of Sprinklers System in Hospital
title_short The Performance-Based Design of Sprinklers System in Hospital
title_full The Performance-Based Design of Sprinklers System in Hospital
title_fullStr The Performance-Based Design of Sprinklers System in Hospital
title_full_unstemmed The Performance-Based Design of Sprinklers System in Hospital
title_sort performance-based design of sprinklers system in hospital
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/33694485850671795232
work_keys_str_mv AT yujenchen theperformancebaseddesignofsprinklerssysteminhospital
AT chényòurèn theperformancebaseddesignofsprinklerssysteminhospital
AT yujenchen yīliáoyuànsuǒzìdòngsǎshuǐshèbèixìngnénghuàshèjìzhītàntǎo
AT chényòurèn yīliáoyuànsuǒzìdòngsǎshuǐshèbèixìngnénghuàshèjìzhītàntǎo
AT yujenchen performancebaseddesignofsprinklerssysteminhospital
AT chényòurèn performancebaseddesignofsprinklerssysteminhospital
_version_ 1718292144306782208