The Performance Based Design of Fire Detectors

碩士 === 長榮大學 === 職業安全與衛生學系碩士班 === 94 === In Taiwan, the fire protection regulations often define some rigid requirements that can't be altered. If we can cooperate with the most popular Performance Based Design (PBD), we can solve the problems that a lot of traditional regulations can't be...

Full description

Bibliographic Details
Main Authors: Hong-Xiang Chen, 陳泓翔
Other Authors: San-Ping Ho
Format: Others
Language:zh-TW
Published: 2006
Online Access:http://ndltd.ncl.edu.tw/handle/16036435534610368541
id ndltd-TW-094CJU00590004
record_format oai_dc
spelling ndltd-TW-094CJU005900042015-12-21T04:04:53Z http://ndltd.ncl.edu.tw/handle/16036435534610368541 The Performance Based Design of Fire Detectors 火警探測器之性能化設計 Hong-Xiang Chen 陳泓翔 碩士 長榮大學 職業安全與衛生學系碩士班 94 In Taiwan, the fire protection regulations often define some rigid requirements that can't be altered. If we can cooperate with the most popular Performance Based Design (PBD), we can solve the problems that a lot of traditional regulations can't be solved. According to the test standards of fixed temperature heat detectors in Taiwan, this research found Response Time Index (RTI) of heat detectors was fixed no matter what activation temperature is. But the test standards of this and Underwriters Laboratories (UL) are different in some requirements. And the fire protection regulations in Taiwan can be improved to better, especially when there is a beam in the room. If the beam’s height exceeds 40cm, we should divide the room into two blocks; if the height is under 40cm, need not be divided into two blocks. This regulation also differs from norm of 72 of U.S.A. NFPA (National Fire Protection Association) greatly. According to the simulation result of this research, beams had significant effects to heat detector actuation in the large room area, Moreover, general cognition about the temperature rising curve of steady state fire (oil fire) differs from actual fire test. Fire Dynamics Simulator (FDS) overestimated the temperature curve of a pool fire scenario. A better FDS simulation could be obtained by using the temperature rising curve data from a heptanes’ oil fire. The domestic regulations are more conservative in lower room temperature occupancy, but U.S. regulations provide the better protection requirements in higher room temperature occupancy. The smoke detectors are necessary to classify to three groups from the sensitivity tests. San-Ping Ho 何三平 2006 學位論文 ; thesis 68 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 長榮大學 === 職業安全與衛生學系碩士班 === 94 === In Taiwan, the fire protection regulations often define some rigid requirements that can't be altered. If we can cooperate with the most popular Performance Based Design (PBD), we can solve the problems that a lot of traditional regulations can't be solved. According to the test standards of fixed temperature heat detectors in Taiwan, this research found Response Time Index (RTI) of heat detectors was fixed no matter what activation temperature is. But the test standards of this and Underwriters Laboratories (UL) are different in some requirements. And the fire protection regulations in Taiwan can be improved to better, especially when there is a beam in the room. If the beam’s height exceeds 40cm, we should divide the room into two blocks; if the height is under 40cm, need not be divided into two blocks. This regulation also differs from norm of 72 of U.S.A. NFPA (National Fire Protection Association) greatly. According to the simulation result of this research, beams had significant effects to heat detector actuation in the large room area, Moreover, general cognition about the temperature rising curve of steady state fire (oil fire) differs from actual fire test. Fire Dynamics Simulator (FDS) overestimated the temperature curve of a pool fire scenario. A better FDS simulation could be obtained by using the temperature rising curve data from a heptanes’ oil fire. The domestic regulations are more conservative in lower room temperature occupancy, but U.S. regulations provide the better protection requirements in higher room temperature occupancy. The smoke detectors are necessary to classify to three groups from the sensitivity tests.
author2 San-Ping Ho
author_facet San-Ping Ho
Hong-Xiang Chen
陳泓翔
author Hong-Xiang Chen
陳泓翔
spellingShingle Hong-Xiang Chen
陳泓翔
The Performance Based Design of Fire Detectors
author_sort Hong-Xiang Chen
title The Performance Based Design of Fire Detectors
title_short The Performance Based Design of Fire Detectors
title_full The Performance Based Design of Fire Detectors
title_fullStr The Performance Based Design of Fire Detectors
title_full_unstemmed The Performance Based Design of Fire Detectors
title_sort performance based design of fire detectors
publishDate 2006
url http://ndltd.ncl.edu.tw/handle/16036435534610368541
work_keys_str_mv AT hongxiangchen theperformancebaseddesignoffiredetectors
AT chénhóngxiáng theperformancebaseddesignoffiredetectors
AT hongxiangchen huǒjǐngtàncèqìzhīxìngnénghuàshèjì
AT chénhóngxiáng huǒjǐngtàncèqìzhīxìngnénghuàshèjì
AT hongxiangchen performancebaseddesignoffiredetectors
AT chénhóngxiáng performancebaseddesignoffiredetectors
_version_ 1718155228199518208