Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer

碩士 === 元培科學技術學院 === 影像醫學研究所 === 95 === Abstract The dosimetry verification of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new two-dimensional diode array and assess the role it can play in routine IMR...

Full description

Bibliographic Details
Main Authors: Meng-Tsung LIN, 林孟聰
Other Authors: 王愛義
Format: Others
Language:zh-TW
Published: 2007
Online Access:http://ndltd.ncl.edu.tw/handle/892c6j
id ndltd-TW-093YUST7770002
record_format oai_dc
spelling ndltd-TW-093YUST77700022018-04-28T04:30:47Z http://ndltd.ncl.edu.tw/handle/892c6j Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer 攝護腺癌強度調控放射治療之劑量驗證 Meng-Tsung LIN 林孟聰 碩士 元培科學技術學院 影像醫學研究所 95 Abstract The dosimetry verification of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new two-dimensional diode array and assess the role it can play in routine IMRT dosimetry verification. Hybridize the patient plan to a solid water phantom using the "create verification plan" in the Eclipse treatment planning system and re-calculate the dose distribution in the phantom. Typically, the dosimetry verification process consists of verifying the absolute dose delivered to a reference point, and also the relative planar isodose distribution. Measurements of relative beam dosimetry were made with the diode array and compared with those made with film and ion chamber. The diode array response is linear with dose up to 400 cGy. Clinical performance of the MapCheck for relative and absolute dosimetry is demonstrated with prostate IMRT plans, and compares well with film and ion chamber measurements. The MapCheck offers the dosimetric characteristics required for performing both relative and absolute dose measurements. Its use in the clinic can simplify and reduce the IMRT dosimetry verification workload. 王愛義 2007 學位論文 ; thesis 0 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 元培科學技術學院 === 影像醫學研究所 === 95 === Abstract The dosimetry verification of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new two-dimensional diode array and assess the role it can play in routine IMRT dosimetry verification. Hybridize the patient plan to a solid water phantom using the "create verification plan" in the Eclipse treatment planning system and re-calculate the dose distribution in the phantom. Typically, the dosimetry verification process consists of verifying the absolute dose delivered to a reference point, and also the relative planar isodose distribution. Measurements of relative beam dosimetry were made with the diode array and compared with those made with film and ion chamber. The diode array response is linear with dose up to 400 cGy. Clinical performance of the MapCheck for relative and absolute dosimetry is demonstrated with prostate IMRT plans, and compares well with film and ion chamber measurements. The MapCheck offers the dosimetric characteristics required for performing both relative and absolute dose measurements. Its use in the clinic can simplify and reduce the IMRT dosimetry verification workload.
author2 王愛義
author_facet 王愛義
Meng-Tsung LIN
林孟聰
author Meng-Tsung LIN
林孟聰
spellingShingle Meng-Tsung LIN
林孟聰
Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer
author_sort Meng-Tsung LIN
title Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer
title_short Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer
title_full Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer
title_fullStr Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer
title_full_unstemmed Dose Verification for Intensity Modulated Radiotherapy of Prostate Cancer
title_sort dose verification for intensity modulated radiotherapy of prostate cancer
publishDate 2007
url http://ndltd.ncl.edu.tw/handle/892c6j
work_keys_str_mv AT mengtsunglin doseverificationforintensitymodulatedradiotherapyofprostatecancer
AT línmèngcōng doseverificationforintensitymodulatedradiotherapyofprostatecancer
AT mengtsunglin shèhùxiànáiqiángdùdiàokòngfàngshèzhìliáozhījìliàngyànzhèng
AT línmèngcōng shèhùxiànáiqiángdùdiàokòngfàngshèzhìliáozhījìliàngyànzhèng
_version_ 1718633400876662784