Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection

碩士 === 國立臺灣大學 === 獸醫學研究所 === 93 === The study was to develop a high performance liquid chromatography (HPLC) method for determination of amoxicillin and ampicillin in feeds. Fluorescence detector was set at excitation wavelength of 358 nm and emission wavelength of 440 nm. A SymmetryShield® column...

Full description

Bibliographic Details
Main Authors: Chi-Ho Liu, 劉其和
Other Authors: 張紹光
Format: Others
Language:zh-TW
Published: 2005
Online Access:http://ndltd.ncl.edu.tw/handle/73197241533939902494
id ndltd-TW-093NTU05541035
record_format oai_dc
spelling ndltd-TW-093NTU055410352015-10-13T11:12:49Z http://ndltd.ncl.edu.tw/handle/73197241533939902494 Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection 運用高效液相層析法對飼料中安默西林及安比西林檢測方法之建立 Chi-Ho Liu 劉其和 碩士 國立臺灣大學 獸醫學研究所 93 The study was to develop a high performance liquid chromatography (HPLC) method for determination of amoxicillin and ampicillin in feeds. Fluorescence detector was set at excitation wavelength of 358 nm and emission wavelength of 440 nm. A SymmetryShield® column (RP8, 5 μm, 4.6 × 250 mm I.D.) with a mobile phase consisting of 0.01 M potassium dihydrogen phosphate (pH 2.5):acetonitrile (82: 18, v/v) was used. The average recoveries of amoxicillin and ampicillin from spiked samples were 93.28 – 102.69 % and 88.35 – 106.14 % with repeatabilities below 4 % R.S.D.. The limits of detection of amoxicillin and ampicillin were 0.3536 and 0.0269 mg/kg, the limits of quantitation were 1.1787 and 0.0896 mg/kg for feed, respectively. Not only the method of validation was performed, but also specificity, reproducibility, precision and accuracy were confirmed. This assay has been applied to the measurement of amoxicillin and ampicillin in feeds. 張紹光 2005 學位論文 ; thesis 74 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 獸醫學研究所 === 93 === The study was to develop a high performance liquid chromatography (HPLC) method for determination of amoxicillin and ampicillin in feeds. Fluorescence detector was set at excitation wavelength of 358 nm and emission wavelength of 440 nm. A SymmetryShield® column (RP8, 5 μm, 4.6 × 250 mm I.D.) with a mobile phase consisting of 0.01 M potassium dihydrogen phosphate (pH 2.5):acetonitrile (82: 18, v/v) was used. The average recoveries of amoxicillin and ampicillin from spiked samples were 93.28 – 102.69 % and 88.35 – 106.14 % with repeatabilities below 4 % R.S.D.. The limits of detection of amoxicillin and ampicillin were 0.3536 and 0.0269 mg/kg, the limits of quantitation were 1.1787 and 0.0896 mg/kg for feed, respectively. Not only the method of validation was performed, but also specificity, reproducibility, precision and accuracy were confirmed. This assay has been applied to the measurement of amoxicillin and ampicillin in feeds.
author2 張紹光
author_facet 張紹光
Chi-Ho Liu
劉其和
author Chi-Ho Liu
劉其和
spellingShingle Chi-Ho Liu
劉其和
Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
author_sort Chi-Ho Liu
title Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
title_short Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
title_full Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
title_fullStr Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
title_full_unstemmed Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
title_sort simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
publishDate 2005
url http://ndltd.ncl.edu.tw/handle/73197241533939902494
work_keys_str_mv AT chiholiu simultaneousdeterminationofamoxicillinandampicillininfeedbyliquidchromatographywithfluorescencedetection
AT liúqíhé simultaneousdeterminationofamoxicillinandampicillininfeedbyliquidchromatographywithfluorescencedetection
AT chiholiu yùnyònggāoxiàoyèxiāngcéngxīfǎduìsìliàozhōngānmòxīlínjíānbǐxīlínjiǎncèfāngfǎzhījiànlì
AT liúqíhé yùnyònggāoxiàoyèxiāngcéngxīfǎduìsìliàozhōngānmòxīlínjíānbǐxīlínjiǎncèfāngfǎzhījiànlì
_version_ 1716840144980410368