Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement

碩士 === 國立臺灣大學 === 醫學工程學研究所 === 93 ===   In this research, we developed Microelectrode Array(MEA) chip and measured platform for zebrafish and zebrafish embryo ECG signals and other bio-potential signals .This platform also used in any MEA chip to measure any bio-potential signals.   MEA chip is fabr...

Full description

Bibliographic Details
Main Authors: Jin-Jiang Kao, 高錦江
Other Authors: Chii-Wann Lin
Format: Others
Language:zh-TW
Published: 2005
Online Access:http://ndltd.ncl.edu.tw/handle/83926854515039024301
id ndltd-TW-093NTU05530051
record_format oai_dc
spelling ndltd-TW-093NTU055300512015-10-13T11:12:50Z http://ndltd.ncl.edu.tw/handle/83926854515039024301 Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement 微電極陣列系統於斑馬魚生理電訊號量測應用 Jin-Jiang Kao 高錦江 碩士 國立臺灣大學 醫學工程學研究所 93   In this research, we developed Microelectrode Array(MEA) chip and measured platform for zebrafish and zebrafish embryo ECG signals and other bio-potential signals .This platform also used in any MEA chip to measure any bio-potential signals.   MEA chip is fabricated by using Micro-Electro Machanical System(MEMS) processes. The substrate of MEA chip is glass, and the conduction-line-layer is used Ti(Titanium), Cr(Chromium), ITO(Indium Tin Oxide), and etc. The Bio-Connect-layer is used Au(Gold), ITO, and Pt(Platinum). Our MEA chips are composed of 64 electrodes arranged in an 8 × 8 matrix. The electrodes area are 20 × 20μm2 and 40 × 40μm2. The interval between the two electrodes measures 120μm and 100μm. The sensing area are 1.02 × 1.02mm2 and 1.04 × 1.04mm2.   The measurement platform comprise chip holder, measurement circuits, and LabVIEW software platform. We design 64 number of Measurement circuits. Measurement circuits comprise instrumentation pre-amplifier, 300Hz low pass filter, 0.1Hz high pass filter, 60Hz notch filter, and post-amplifier. Becaure DAQ card is limited number of analog signals channels, we design analog multiplexer. We use LabVIEW to control analog multiplexer to catch signals to computer. Chii-Wann Lin 林啟萬 2005 學位論文 ; thesis 74 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 醫學工程學研究所 === 93 ===   In this research, we developed Microelectrode Array(MEA) chip and measured platform for zebrafish and zebrafish embryo ECG signals and other bio-potential signals .This platform also used in any MEA chip to measure any bio-potential signals.   MEA chip is fabricated by using Micro-Electro Machanical System(MEMS) processes. The substrate of MEA chip is glass, and the conduction-line-layer is used Ti(Titanium), Cr(Chromium), ITO(Indium Tin Oxide), and etc. The Bio-Connect-layer is used Au(Gold), ITO, and Pt(Platinum). Our MEA chips are composed of 64 electrodes arranged in an 8 × 8 matrix. The electrodes area are 20 × 20μm2 and 40 × 40μm2. The interval between the two electrodes measures 120μm and 100μm. The sensing area are 1.02 × 1.02mm2 and 1.04 × 1.04mm2.   The measurement platform comprise chip holder, measurement circuits, and LabVIEW software platform. We design 64 number of Measurement circuits. Measurement circuits comprise instrumentation pre-amplifier, 300Hz low pass filter, 0.1Hz high pass filter, 60Hz notch filter, and post-amplifier. Becaure DAQ card is limited number of analog signals channels, we design analog multiplexer. We use LabVIEW to control analog multiplexer to catch signals to computer.
author2 Chii-Wann Lin
author_facet Chii-Wann Lin
Jin-Jiang Kao
高錦江
author Jin-Jiang Kao
高錦江
spellingShingle Jin-Jiang Kao
高錦江
Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement
author_sort Jin-Jiang Kao
title Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement
title_short Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement
title_full Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement
title_fullStr Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement
title_full_unstemmed Microelectrode Array System for Zebrafish Bio-Potential Signals Measurement
title_sort microelectrode array system for zebrafish bio-potential signals measurement
publishDate 2005
url http://ndltd.ncl.edu.tw/handle/83926854515039024301
work_keys_str_mv AT jinjiangkao microelectrodearraysystemforzebrafishbiopotentialsignalsmeasurement
AT gāojǐnjiāng microelectrodearraysystemforzebrafishbiopotentialsignalsmeasurement
AT jinjiangkao wēidiànjízhènlièxìtǒngyúbānmǎyúshēnglǐdiànxùnhàoliàngcèyīngyòng
AT gāojǐnjiāng wēidiànjízhènlièxìtǒngyúbānmǎyúshēnglǐdiànxùnhàoliàngcèyīngyòng
_version_ 1716840674731491328