A Study of Microbubble Generator and Its Applications
碩士 === 國立臺灣大學 === 應用力學研究所 === 93 === Generation of single microbubble by injection in microchannel has been investigated in this thesis. Microbubble generator is a cross type microchannel configured with contraction section. To analyze microbubble generation, two different contraction angles, 10° an...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Online Access: | http://ndltd.ncl.edu.tw/handle/2jctye |
id |
ndltd-TW-093NTU05499062 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-093NTU054990622019-05-15T19:18:31Z http://ndltd.ncl.edu.tw/handle/2jctye A Study of Microbubble Generator and Its Applications 微氣泡產生器之研究及其應用 Yi-Hua Wang 王怡華 碩士 國立臺灣大學 應用力學研究所 93 Generation of single microbubble by injection in microchannel has been investigated in this thesis. Microbubble generator is a cross type microchannel configured with contraction section. To analyze microbubble generation, two different contraction angles, 10° and 15° have been experimentally studied. Microchannels are fabricated in PDMS (polydimethysiloxane) by using soft lithography technique. Method of microbubble generation is to stop gas-liquid interface by contraction and segment gas stream into designed length by liquid from side channels. Stop position analysis shows that contraction channel stops the gas injection indeed. Further, by repeating the sequences of single microbubble generation in order to form microbubbly flow, and a model of microbubbly flow is developed preliminarily. Namely, a novel method for microbubbly flow formation is proposed in this thesis. 王安邦 學位論文 ; thesis 42 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣大學 === 應用力學研究所 === 93 === Generation of single microbubble by injection in microchannel has been investigated in this thesis. Microbubble generator is a cross type microchannel configured with contraction section. To analyze microbubble generation, two different contraction angles, 10° and 15° have been experimentally studied. Microchannels are fabricated in PDMS (polydimethysiloxane) by using soft lithography technique. Method of microbubble generation is to stop gas-liquid interface by contraction and segment gas stream into designed length by liquid from side channels. Stop position analysis shows that contraction channel stops the gas injection indeed. Further, by repeating the sequences of single microbubble generation in order to form microbubbly flow, and a model of microbubbly flow is developed preliminarily. Namely, a novel method for microbubbly flow formation is proposed in this thesis.
|
author2 |
王安邦 |
author_facet |
王安邦 Yi-Hua Wang 王怡華 |
author |
Yi-Hua Wang 王怡華 |
spellingShingle |
Yi-Hua Wang 王怡華 A Study of Microbubble Generator and Its Applications |
author_sort |
Yi-Hua Wang |
title |
A Study of Microbubble Generator and Its Applications |
title_short |
A Study of Microbubble Generator and Its Applications |
title_full |
A Study of Microbubble Generator and Its Applications |
title_fullStr |
A Study of Microbubble Generator and Its Applications |
title_full_unstemmed |
A Study of Microbubble Generator and Its Applications |
title_sort |
study of microbubble generator and its applications |
url |
http://ndltd.ncl.edu.tw/handle/2jctye |
work_keys_str_mv |
AT yihuawang astudyofmicrobubblegeneratoranditsapplications AT wángyíhuá astudyofmicrobubblegeneratoranditsapplications AT yihuawang wēiqìpàochǎnshēngqìzhīyánjiūjíqíyīngyòng AT wángyíhuá wēiqìpàochǎnshēngqìzhīyánjiūjíqíyīngyòng AT yihuawang studyofmicrobubblegeneratoranditsapplications AT wángyíhuá studyofmicrobubblegeneratoranditsapplications |
_version_ |
1719087322328203264 |