Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System
碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 93 === The goal of this research is to develop a wireless physiological monitoring system and to test its performance. The wireless physiological monitoring system was implemented on an internet-based software environment to allow for data acquisition, transmission...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2005
|
Online Access: | http://ndltd.ncl.edu.tw/handle/24184610825290641358 |
id |
ndltd-TW-093NTU05415013 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-093NTU054150132015-12-21T04:04:13Z http://ndltd.ncl.edu.tw/handle/24184610825290641358 Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System 整合無線通訊與網路技術之生理訊號監測系統研究 Jr-Shin Chen 陳致信 碩士 國立臺灣大學 生物產業機電工程學研究所 93 The goal of this research is to develop a wireless physiological monitoring system and to test its performance. The wireless physiological monitoring system was implemented on an internet-based software environment to allow for data acquisition, transmission and analyses. This wireless physiological monitoring system can be divided into four subsystems; a physiological signal sensor component, a microprocessor, a bluetooth wireless module and an integrated software. The physiological signal sensor component is composed of electrode patches and an instrumentation amplifier. Electrode patches is attached to the patient’s heart area. After the electrode patches receive the signal from the heart, the differential signal is measured and then amplified and filtered for the final output of ECG signal. The ECG signal is transmitted to the program running on a personal computer via bluetooth wireless module to capture those signals for future analysis and processing. The microprocessor uses its ADC (analog to digital converter) to process the analog signals received from the physiological signal sensor component and convert it to hexadecimal digital code. The bluetooth wireless module transmits those signals back to the server wirelessly. The integrated software system then converts those digital signals into wave signals and presents them on the monitoring screen simultaneously. On the other hand, the integrated software system also conforms to the server’s setting and presents these data on the websites so that physician and nurses can use the internet browser to get the most recent info of the monitoring system. This physiological monitoring system can monitor three patients at a time and can be extended to more patients. The size of each portable hardware is about 90×55×20 mm3. This portable hardware can detect patient’s ECG signal, heart rate, and body temperature. 林達德 2005 學位論文 ; thesis 86 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 93 === The goal of this research is to develop a wireless physiological monitoring system and to test its performance. The wireless physiological monitoring system was implemented on an internet-based software environment to allow for data acquisition, transmission and analyses. This wireless physiological monitoring system can be divided into four subsystems; a physiological signal sensor component, a microprocessor, a bluetooth wireless module and an integrated software. The physiological signal sensor component is composed of electrode patches and an instrumentation amplifier. Electrode patches is attached to the patient’s heart area. After the electrode patches receive the signal from the heart, the differential signal is measured and then amplified and filtered for the final output of ECG signal. The ECG signal is transmitted to the program running on a personal computer via bluetooth wireless module to capture those signals for future analysis and processing. The microprocessor uses its ADC (analog to digital converter) to process the analog signals received from the physiological signal sensor component and convert it to hexadecimal digital code. The bluetooth wireless module transmits those signals back to the server wirelessly. The integrated software system then converts those digital signals into wave signals and presents them on the monitoring screen simultaneously. On the other hand, the integrated software system also conforms to the server’s setting and presents these data on the websites so that physician and nurses can use the internet browser to get the most recent info of the monitoring system. This physiological monitoring system can monitor three patients at a time and can be extended to more patients. The size of each portable hardware is about 90×55×20 mm3. This portable hardware can detect patient’s ECG signal, heart rate, and body temperature.
|
author2 |
林達德 |
author_facet |
林達德 Jr-Shin Chen 陳致信 |
author |
Jr-Shin Chen 陳致信 |
spellingShingle |
Jr-Shin Chen 陳致信 Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System |
author_sort |
Jr-Shin Chen |
title |
Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System |
title_short |
Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System |
title_full |
Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System |
title_fullStr |
Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System |
title_full_unstemmed |
Integration of Wireless Communication and Internet Technology for a Physiological Monitoring System |
title_sort |
integration of wireless communication and internet technology for a physiological monitoring system |
publishDate |
2005 |
url |
http://ndltd.ncl.edu.tw/handle/24184610825290641358 |
work_keys_str_mv |
AT jrshinchen integrationofwirelesscommunicationandinternettechnologyforaphysiologicalmonitoringsystem AT chénzhìxìn integrationofwirelesscommunicationandinternettechnologyforaphysiologicalmonitoringsystem AT jrshinchen zhěnghéwúxiàntōngxùnyǔwǎnglùjìshùzhīshēnglǐxùnhàojiāncèxìtǒngyánjiū AT chénzhìxìn zhěnghéwúxiàntōngxùnyǔwǎnglùjìshùzhīshēnglǐxùnhàojiāncèxìtǒngyánjiū |
_version_ |
1718154600779874304 |