Development of High Precision Multi-Axis Laser Scanning System

碩士 === 國立清華大學 === 動力機械工程學系 === 93 === The objective of this thesis is to develop a high-precision multi-axis laser scanning system for small workpieces, including a 4-axis laser scanning machine, a control system and data processing software. The workpiece can be moved by a rotary axis and linear st...

Full description

Bibliographic Details
Main Authors: Ming-Yen Ho, 何銘晏
Other Authors: Wei-Tai Lei
Format: Others
Language:zh-TW
Published: 2005
Online Access:http://ndltd.ncl.edu.tw/handle/97506921917429300578
id ndltd-TW-093NTHU5311078
record_format oai_dc
spelling ndltd-TW-093NTHU53110782016-06-06T04:11:36Z http://ndltd.ncl.edu.tw/handle/97506921917429300578 Development of High Precision Multi-Axis Laser Scanning System 高精度多軸雷射掃瞄機系統研發 Ming-Yen Ho 何銘晏 碩士 國立清華大學 動力機械工程學系 93 The objective of this thesis is to develop a high-precision multi-axis laser scanning system for small workpieces, including a 4-axis laser scanning machine, a control system and data processing software. The workpiece can be moved by a rotary axis and linear stages according to designed paths. Therefore, the machine can digitizes the 3D profile of a workpiece by a single point laser head. The whole measuring precision is in μm scale which is higher than the existing products on the market. In addition, this thesis proposes a new data simplification algorithm and a new data registration procedure. The data simplification algorithm can remove inappropriate or unnecessary points by the direction of the concaves. For data registration, this paper proposes a new method named “Data Registration Based on Explicit Coordinate Transformation”. The method calculates the axial of the rotation axis and the offset between the reference coordinate and the workpiece coordinate by a standard ball in advance. Therefore, the actual positions of the measured points in workpiece coordinate can be calculated by the rotary angle and the Homogeneous Transformation Matrix (HTM). In other words, the measured points can be transformed to the same coordinate and the data registration can be made. The method can avoid a large amount of calculation and local optimal problem of the Iterative Closest Point (ICP) algorithm. Besides, the method not only can be used in the machine we developed in this thesis but also can apply to any machine tools with rotary axis to set up accurate transformation parameters, improving the precision of the machine by a wide margin. Wei-Tai Lei 雷衛台 2005 學位論文 ; thesis 96 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 動力機械工程學系 === 93 === The objective of this thesis is to develop a high-precision multi-axis laser scanning system for small workpieces, including a 4-axis laser scanning machine, a control system and data processing software. The workpiece can be moved by a rotary axis and linear stages according to designed paths. Therefore, the machine can digitizes the 3D profile of a workpiece by a single point laser head. The whole measuring precision is in μm scale which is higher than the existing products on the market. In addition, this thesis proposes a new data simplification algorithm and a new data registration procedure. The data simplification algorithm can remove inappropriate or unnecessary points by the direction of the concaves. For data registration, this paper proposes a new method named “Data Registration Based on Explicit Coordinate Transformation”. The method calculates the axial of the rotation axis and the offset between the reference coordinate and the workpiece coordinate by a standard ball in advance. Therefore, the actual positions of the measured points in workpiece coordinate can be calculated by the rotary angle and the Homogeneous Transformation Matrix (HTM). In other words, the measured points can be transformed to the same coordinate and the data registration can be made. The method can avoid a large amount of calculation and local optimal problem of the Iterative Closest Point (ICP) algorithm. Besides, the method not only can be used in the machine we developed in this thesis but also can apply to any machine tools with rotary axis to set up accurate transformation parameters, improving the precision of the machine by a wide margin.
author2 Wei-Tai Lei
author_facet Wei-Tai Lei
Ming-Yen Ho
何銘晏
author Ming-Yen Ho
何銘晏
spellingShingle Ming-Yen Ho
何銘晏
Development of High Precision Multi-Axis Laser Scanning System
author_sort Ming-Yen Ho
title Development of High Precision Multi-Axis Laser Scanning System
title_short Development of High Precision Multi-Axis Laser Scanning System
title_full Development of High Precision Multi-Axis Laser Scanning System
title_fullStr Development of High Precision Multi-Axis Laser Scanning System
title_full_unstemmed Development of High Precision Multi-Axis Laser Scanning System
title_sort development of high precision multi-axis laser scanning system
publishDate 2005
url http://ndltd.ncl.edu.tw/handle/97506921917429300578
work_keys_str_mv AT mingyenho developmentofhighprecisionmultiaxislaserscanningsystem
AT hémíngyàn developmentofhighprecisionmultiaxislaserscanningsystem
AT mingyenho gāojīngdùduōzhóuléishèsǎomiáojīxìtǒngyánfā
AT hémíngyàn gāojīngdùduōzhóuléishèsǎomiáojīxìtǒngyánfā
_version_ 1718296310869655552