The Fabrication and Evaluation of HA/PLLA Porous Membrane for Wound Dressing
碩士 === 國立交通大學 === 機械工程系所 === 93 === In this experiment, a series of columnar array served as punches were fabricated on silicon wafer by semiconductor manufacture process. In the mean time HA/PLLA membranes were prepared by spin coating upon the surface of wafer. Then the membranes were punched by...
Main Authors: | Tian-Huang Qiu, 邱添煌 |
---|---|
Other Authors: | Ray-Quen Hsu |
Format: | Others |
Language: | zh-TW |
Published: |
2005
|
Online Access: | http://ndltd.ncl.edu.tw/handle/78011615026967785641 |
Similar Items
-
Physical Properties and In Vivo Study of Porous Biodegradable PLLA/ HA Composites
by: Hsiung Ching-fang, et al.
Published: (2002) -
Correction: A Comparative Study on Osteogenic Priming Potential of Electron Spun Scaffold PLLA/HA/Col, PLLA/HA, and PLLA/Col for Tissue Engineering Application.
Published: (2014-01-01) -
A comparative study on in vitro osteogenic priming potential of electron spun scaffold PLLA/HA/Col, PLLA/HA, and PLLA/Col for tissue engineering application.
by: Hanumantha Rao Balaji Raghavendran, et al.
Published: (2014-01-01) -
Correction: A Comparative Study on In Vitro Osteogenic Priming Potential of Electron Spun Scaffold PLLA/HA/Col, PLLA/HA, and PLLA/Col for Tissue Engineering Application
by: The Staff
Published: (2014-01-01) -
The study on the membrane structure of PLLA and PLLA/PEG blends
by: Yi-Hsiu Liu, et al.
Published: (2003)