The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan

碩士 === 國立成功大學 === 建築學系專班 === 93 ===  “Open education” is a philosophy which is new and developing in Taiwan. Under the influence of the emerging idea for education, the design concept of “clustered classroom” has become prevailing in school planning, no matter in new or renovated primary schools sin...

Full description

Bibliographic Details
Main Authors: Chen-Yen Huang, 黃貞燕
Other Authors: Che-Min Chiang
Format: Others
Language:zh-TW
Published: 2005
Online Access:http://ndltd.ncl.edu.tw/handle/67895236153247797404
id ndltd-TW-093NCKU5222050
record_format oai_dc
spelling ndltd-TW-093NCKU52220502017-08-27T04:29:40Z http://ndltd.ncl.edu.tw/handle/67895236153247797404 The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan 班群教室室內物理環境品質之研究-以高雄市為例 Chen-Yen Huang 黃貞燕 碩士 國立成功大學 建築學系專班 93  “Open education” is a philosophy which is new and developing in Taiwan. Under the influence of the emerging idea for education, the design concept of “clustered classroom” has become prevailing in school planning, no matter in new or renovated primary schools since 1999. The study emphasizes on the indoor environmental quality of “clustered classroom” in 4 schools in Kaohsiung, which are the most experienced (for 6 years)in the application of the design concept. For the comparison, 15 classrooms including 4 traditional samples are investigated by questionnaire survey, detailed monitoring at the same time. After the analysis and comparison of IEQ problems between clustered classrooms and traditional classrooms, the summary of the results are as follows:  1.Noise All types of classrooms exceeded the acoustic standards of 55 dB(A) for 20dB(A) during the students’ lesson hours in window opened condition. The suggested range of reverberation times in unoccupied classrooms is 0.8~1.0 seconds. All kinds of classrooms were above the suggested range. The reverberation times in clustered classrooms were longer than the traditional classrooms, because of the difference of room capacity and the building material.    2.Light To classify the units of cluttered classrooms, there were three types of opening pattern: single directional opening, bi-directional horizontal opening and bi-directional vertical opening. Without using auxiliary lighting, the single directional opening units and bi-directional vertical opening units were all poor lighting intensity and uniformity ratio of illuminance. And the bi-directional horizontal opening had higher daylight factor than the other two kinds of patterns.  3.Thermal comfort Almost half of clustered classrooms exceeded the ISO-7730 thermal comfort standards for PMV value for 0.04~0.44, during January to April 2005. All the traditional classrooms, which were measured in May, 2005, the PMV mean value exceeded the thermal comfort standards for 2.03. That was seriously over the thermal comfort scale.  4.Air quality The indoor carbon monoxide(CO)and carbon dioxide(CO2)levels were measured continuously throughout one school day. The clustered classrooms were measured in the natural ventilated condition, and the traditional classrooms were measured in natural and mechanical ventilated condition. The CO and CO2 levels in all cases were within the standard range. But the indoor PM10 concentration exceeded the suggested limit in some clustered classrooms. Che-Min Chiang 江哲銘 2005 學位論文 ; thesis 94 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 建築學系專班 === 93 ===  “Open education” is a philosophy which is new and developing in Taiwan. Under the influence of the emerging idea for education, the design concept of “clustered classroom” has become prevailing in school planning, no matter in new or renovated primary schools since 1999. The study emphasizes on the indoor environmental quality of “clustered classroom” in 4 schools in Kaohsiung, which are the most experienced (for 6 years)in the application of the design concept. For the comparison, 15 classrooms including 4 traditional samples are investigated by questionnaire survey, detailed monitoring at the same time. After the analysis and comparison of IEQ problems between clustered classrooms and traditional classrooms, the summary of the results are as follows:  1.Noise All types of classrooms exceeded the acoustic standards of 55 dB(A) for 20dB(A) during the students’ lesson hours in window opened condition. The suggested range of reverberation times in unoccupied classrooms is 0.8~1.0 seconds. All kinds of classrooms were above the suggested range. The reverberation times in clustered classrooms were longer than the traditional classrooms, because of the difference of room capacity and the building material.    2.Light To classify the units of cluttered classrooms, there were three types of opening pattern: single directional opening, bi-directional horizontal opening and bi-directional vertical opening. Without using auxiliary lighting, the single directional opening units and bi-directional vertical opening units were all poor lighting intensity and uniformity ratio of illuminance. And the bi-directional horizontal opening had higher daylight factor than the other two kinds of patterns.  3.Thermal comfort Almost half of clustered classrooms exceeded the ISO-7730 thermal comfort standards for PMV value for 0.04~0.44, during January to April 2005. All the traditional classrooms, which were measured in May, 2005, the PMV mean value exceeded the thermal comfort standards for 2.03. That was seriously over the thermal comfort scale.  4.Air quality The indoor carbon monoxide(CO)and carbon dioxide(CO2)levels were measured continuously throughout one school day. The clustered classrooms were measured in the natural ventilated condition, and the traditional classrooms were measured in natural and mechanical ventilated condition. The CO and CO2 levels in all cases were within the standard range. But the indoor PM10 concentration exceeded the suggested limit in some clustered classrooms.
author2 Che-Min Chiang
author_facet Che-Min Chiang
Chen-Yen Huang
黃貞燕
author Chen-Yen Huang
黃貞燕
spellingShingle Chen-Yen Huang
黃貞燕
The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan
author_sort Chen-Yen Huang
title The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan
title_short The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan
title_full The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan
title_fullStr The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan
title_full_unstemmed The Study of the Physical Indoor Environment for Primary School Classrooms in Kaohsiung, Taiwan
title_sort study of the physical indoor environment for primary school classrooms in kaohsiung, taiwan
publishDate 2005
url http://ndltd.ncl.edu.tw/handle/67895236153247797404
work_keys_str_mv AT chenyenhuang thestudyofthephysicalindoorenvironmentforprimaryschoolclassroomsinkaohsiungtaiwan
AT huángzhēnyàn thestudyofthephysicalindoorenvironmentforprimaryschoolclassroomsinkaohsiungtaiwan
AT chenyenhuang bānqúnjiàoshìshìnèiwùlǐhuánjìngpǐnzhìzhīyánjiūyǐgāoxióngshìwèilì
AT huángzhēnyàn bānqúnjiàoshìshìnèiwùlǐhuánjìngpǐnzhìzhīyánjiūyǐgāoxióngshìwèilì
AT chenyenhuang studyofthephysicalindoorenvironmentforprimaryschoolclassroomsinkaohsiungtaiwan
AT huángzhēnyàn studyofthephysicalindoorenvironmentforprimaryschoolclassroomsinkaohsiungtaiwan
_version_ 1718518439853686784