On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine
碩士 === 高雄醫學大學 === 醫學研究所碩士班 === 93 === Preconcentration techniques play important roles in on-line methods development. In the present study, using a polytetrafluoroethylene (PTFE) tubing preconcentration and flow-injection flame atomic absorption spectrometric detection, we have successfully develop...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2005
|
Online Access: | http://ndltd.ncl.edu.tw/handle/48896411898817297645 |
id |
ndltd-TW-093KMC05534062 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-093KMC055340622015-12-23T04:08:00Z http://ndltd.ncl.edu.tw/handle/48896411898817297645 On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine 利用PTFE管線前濃縮配合流動注入火焰式原子吸收光譜儀之連線檢驗系統進行尿液中鉛與銅之研究 Ting-Ting Yang 楊婷婷 碩士 高雄醫學大學 醫學研究所碩士班 93 Preconcentration techniques play important roles in on-line methods development. In the present study, using a polytetrafluoroethylene (PTFE) tubing preconcentration and flow-injection flame atomic absorption spectrometric detection, we have successfully developed an analytical system for enrichment and determination of trace lead (Pb) and copper (Cu) in urine. The sample mixed with ammonium pyrrolidine dithiocarbamate (APDC) was passing through a PTFE tubing and the Pb (Ⅱ)-PDC and Cu (Ⅱ)-PDC complex were absorbed quantitatively on the tubing. The preconcentrated complex was effectively eluted by hydrochloric acid solution and introduced into the nebulizer-burner system. In this method, 0.2% (v/v) HNO3 solution was used as carrier solution and the optimal flow rate of nebulizer was set at 6.0 mL/min. The calibration curve was linear over the concentration range of 0.1-0.6 mg/L and 0.05-0.4 mg/L for Pb and Cu, respectively. The limits of detection were 25 and 4 mg/L, for lead and copper, respectively. The intra- and inter-assay for lead and copper at three levels of standard solution (0.1, 0.2 and 0.3 mg/L for lead; 0.05, 0.1 and 0.2 mg/L for copper) were less than 7.5 and 7.1%. The recoveries of lead and copper spiked in human urine samples ranged from 96.7 to 108.1% and 93-96% for Pb and Cu, respectively. Furthermore, by comparing the results obtained using the developed on-line preconcentration method and graphite furnace atomic absorption spectrometry, we found the method is reliable for the determination of lead and copper in urine. Yeou-Lih Huang 黃友利 2005 學位論文 ; thesis 96 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 高雄醫學大學 === 醫學研究所碩士班 === 93 === Preconcentration techniques play important roles in on-line methods development. In the present study, using a polytetrafluoroethylene (PTFE) tubing preconcentration and flow-injection flame atomic absorption spectrometric detection, we have successfully developed an analytical system for enrichment and determination of trace lead (Pb) and copper (Cu) in urine. The sample mixed with ammonium pyrrolidine dithiocarbamate (APDC) was passing through a PTFE tubing and the Pb (Ⅱ)-PDC and Cu (Ⅱ)-PDC complex were absorbed quantitatively on the tubing. The preconcentrated complex was effectively eluted by hydrochloric acid solution and introduced into the nebulizer-burner system. In this method, 0.2% (v/v) HNO3 solution was used as carrier solution and the optimal flow rate of nebulizer was set at 6.0 mL/min. The calibration curve was linear over the concentration range of 0.1-0.6 mg/L and 0.05-0.4 mg/L for Pb and Cu, respectively. The limits of detection were 25 and 4 mg/L, for lead and copper, respectively. The intra- and inter-assay for lead and copper at three levels of standard solution (0.1, 0.2 and 0.3 mg/L for lead; 0.05, 0.1 and 0.2 mg/L for copper) were less than 7.5 and 7.1%. The recoveries of lead and copper spiked in human urine samples ranged from 96.7 to 108.1% and 93-96% for Pb and Cu, respectively. Furthermore, by comparing the results obtained using the developed on-line preconcentration method and graphite furnace atomic absorption spectrometry, we found the method is reliable for the determination of lead and copper in urine.
|
author2 |
Yeou-Lih Huang |
author_facet |
Yeou-Lih Huang Ting-Ting Yang 楊婷婷 |
author |
Ting-Ting Yang 楊婷婷 |
spellingShingle |
Ting-Ting Yang 楊婷婷 On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine |
author_sort |
Ting-Ting Yang |
title |
On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine |
title_short |
On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine |
title_full |
On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine |
title_fullStr |
On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine |
title_full_unstemmed |
On-Line PTFE Tubing Preconcentration Device Coupling with FI-FAAS for Determination of Ultra-Trace Lead and Copper in Urine |
title_sort |
on-line ptfe tubing preconcentration device coupling with fi-faas for determination of ultra-trace lead and copper in urine |
publishDate |
2005 |
url |
http://ndltd.ncl.edu.tw/handle/48896411898817297645 |
work_keys_str_mv |
AT tingtingyang onlineptfetubingpreconcentrationdevicecouplingwithfifaasfordeterminationofultratraceleadandcopperinurine AT yángtíngtíng onlineptfetubingpreconcentrationdevicecouplingwithfifaasfordeterminationofultratraceleadandcopperinurine AT tingtingyang lìyòngptfeguǎnxiànqiánnóngsuōpèihéliúdòngzhùrùhuǒyànshìyuánzixīshōuguāngpǔyízhīliánxiànjiǎnyànxìtǒngjìnxíngniàoyèzhōngqiānyǔtóngzhīyánjiū AT yángtíngtíng lìyòngptfeguǎnxiànqiánnóngsuōpèihéliúdòngzhùrùhuǒyànshìyuánzixīshōuguāngpǔyízhīliánxiànjiǎnyànxìtǒngjìnxíngniàoyèzhōngqiānyǔtóngzhīyánjiū |
_version_ |
1718155698608537600 |