A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole
碩士 === 中原大學 === 電機工程研究所 === 93 === Abstract In this thesis, the ground fault characteristics of closed-loop very high voltage(VHV) underground distribution system (VHV underground loop) are studied which includes the ground potential rises(GPR), step and touch voltages on the utility and customer su...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2005
|
Online Access: | http://ndltd.ncl.edu.tw/handle/40213908036261616761 |
id |
ndltd-TW-093CYCU5442043 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-093CYCU54420432015-10-13T15:06:40Z http://ndltd.ncl.edu.tw/handle/40213908036261616761 A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole 考慮人孔接地條件探討特高壓地下環路接地系統之接地故障特性 Chi-Fu Wu 吳基福 碩士 中原大學 電機工程研究所 93 Abstract In this thesis, the ground fault characteristics of closed-loop very high voltage(VHV) underground distribution system (VHV underground loop) are studied which includes the ground potential rises(GPR), step and touch voltages on the utility and customer substation grounding systems and the current distributions on the cable shielding conductors. The grounding conditions of cable shielding conductors are considered which includes common grounding or individual grounding for the cables in the man-holes, the variation of grounding resistances and the on or off states of the surge arresters in the cable-cover-protection unit(CCPU). For a VHV underground loop, the grounding grids in utility and customer substation and the grounding electrodes in the man-holes are connected together via cable shielding conductors and interconnected conductors (auxiliary grounding wires). So, the ground fault current of any one of customer will flow pass through all other customers’ grounding systems and thus produce GPR, step and touch voltages and large current on shielding conductors or flow into surge arresters. These problems have been found from the study results and their affections are also assessed, and this study provide useful data for improving the performances of VHV underground loop. Keyword: very high voltage underground loop, cable grounding Chih-Ju Chou 周至如 2005 學位論文 ; thesis 139 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中原大學 === 電機工程研究所 === 93 === Abstract
In this thesis, the ground fault characteristics of closed-loop very high voltage(VHV) underground distribution system (VHV underground loop) are studied which includes the ground potential rises(GPR), step and touch voltages on the utility and customer substation grounding systems and the current distributions on the cable shielding conductors. The grounding conditions of cable shielding conductors are considered which includes common grounding or individual grounding for the cables in the man-holes, the variation of grounding resistances and the on or off states of the surge arresters in the cable-cover-protection unit(CCPU). For a VHV underground loop, the grounding grids in utility and customer substation and the grounding electrodes in the man-holes are connected together via cable shielding conductors and interconnected conductors (auxiliary grounding wires). So, the ground fault current of any one of customer will flow pass through all other customers’ grounding systems and thus produce GPR, step and touch voltages and large current on shielding conductors or flow into surge arresters. These problems have been found from the study results and their affections are also assessed, and this study provide useful data for improving the performances of VHV underground loop.
Keyword: very high voltage underground loop, cable grounding
|
author2 |
Chih-Ju Chou |
author_facet |
Chih-Ju Chou Chi-Fu Wu 吳基福 |
author |
Chi-Fu Wu 吳基福 |
spellingShingle |
Chi-Fu Wu 吳基福 A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole |
author_sort |
Chi-Fu Wu |
title |
A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole |
title_short |
A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole |
title_full |
A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole |
title_fullStr |
A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole |
title_full_unstemmed |
A study on the Ground Fault Characteristics of Grounding System of Closed-Loop VHV Underground System Considering Grounding Conditions in the Man Hole |
title_sort |
study on the ground fault characteristics of grounding system of closed-loop vhv underground system considering grounding conditions in the man hole |
publishDate |
2005 |
url |
http://ndltd.ncl.edu.tw/handle/40213908036261616761 |
work_keys_str_mv |
AT chifuwu astudyonthegroundfaultcharacteristicsofgroundingsystemofclosedloopvhvundergroundsystemconsideringgroundingconditionsinthemanhole AT wújīfú astudyonthegroundfaultcharacteristicsofgroundingsystemofclosedloopvhvundergroundsystemconsideringgroundingconditionsinthemanhole AT chifuwu kǎolǜrénkǒngjiēdetiáojiàntàntǎotègāoyādexiàhuánlùjiēdexìtǒngzhījiēdegùzhàngtèxìng AT wújīfú kǎolǜrénkǒngjiēdetiáojiàntàntǎotègāoyādexiàhuánlùjiēdexìtǒngzhījiēdegùzhàngtèxìng AT chifuwu studyonthegroundfaultcharacteristicsofgroundingsystemofclosedloopvhvundergroundsystemconsideringgroundingconditionsinthemanhole AT wújīfú studyonthegroundfaultcharacteristicsofgroundingsystemofclosedloopvhvundergroundsystemconsideringgroundingconditionsinthemanhole |
_version_ |
1717761861402755072 |