Development of Lipid Panel Biosensors

博士 === 淡江大學 === 化學學系 === 92 === The goal of this dissertation is to develop a portable electrochemical lipid biosensors for cholesterol, cholesteryl ester, triglyceride, and high density lipoprotein cholesterol respectively. These biosensors can be applied to evaluate the lipid panel and the risky...

Full description

Bibliographic Details
Main Authors: Wei Chung Shih, 施偉仲
Other Authors: Meng Shan Lin
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/58706271544596901094
id ndltd-TW-092TKU00065029
record_format oai_dc
spelling ndltd-TW-092TKU000650292016-06-15T04:16:51Z http://ndltd.ncl.edu.tw/handle/58706271544596901094 Development of Lipid Panel Biosensors 脂質生化感測器之發展研究 Wei Chung Shih 施偉仲 博士 淡江大學 化學學系 92 The goal of this dissertation is to develop a portable electrochemical lipid biosensors for cholesterol, cholesteryl ester, triglyceride, and high density lipoprotein cholesterol respectively. These biosensors can be applied to evaluate the lipid panel and the risky factor for cardiovascular disease in clinical medicine in the future. The integrated three electrode system was screen printed on the top of PP sheet and the electrochemical signal was measured by a home-made portable potentiostat. To improve the selectivity and sensitivity, the sensing strip included the catalyst layer and the enzyme reaction layer to reduce the applied potential and recognize the analyte, the operation conditions were carefully studied. The sensor strips targeting the free cholesterol, total cholesterol (TC), triglyceride(TG) and high density lipoprotein cholesterol (HDL-C) were based on the measurement hydrogen peroxide concentration from above three biosensors and the value of LDL-C can be calculated with reported Friedwald equation, (LDL-C) = (TC)-(HDL-C)-(TG/5), and risky factor equal to (TC)/ (HDL-C) also can be evaluated. The result shows that the detection ranges of biosensors are up to 300 mg/dL for free cholesterol, 500 mg/dL for cholesteryl ester, 750 mg/dL for triglyceride and 110 mg/dL for high density lipoprotein cholesterol. The detection ranges of these electrochemical biosensors are fit for the most clinical requirements. The detection limits according to priority are 17.6, 19.4, 28.2, and 23.2 mg/dL and the measurement time are 25, 20, 65, and 35 sec. These characteristics meet the requirement of clinical needs for lipid assessment. Meng Shan Lin 林孟山 2004 學位論文 ; thesis 212 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 博士 === 淡江大學 === 化學學系 === 92 === The goal of this dissertation is to develop a portable electrochemical lipid biosensors for cholesterol, cholesteryl ester, triglyceride, and high density lipoprotein cholesterol respectively. These biosensors can be applied to evaluate the lipid panel and the risky factor for cardiovascular disease in clinical medicine in the future. The integrated three electrode system was screen printed on the top of PP sheet and the electrochemical signal was measured by a home-made portable potentiostat. To improve the selectivity and sensitivity, the sensing strip included the catalyst layer and the enzyme reaction layer to reduce the applied potential and recognize the analyte, the operation conditions were carefully studied. The sensor strips targeting the free cholesterol, total cholesterol (TC), triglyceride(TG) and high density lipoprotein cholesterol (HDL-C) were based on the measurement hydrogen peroxide concentration from above three biosensors and the value of LDL-C can be calculated with reported Friedwald equation, (LDL-C) = (TC)-(HDL-C)-(TG/5), and risky factor equal to (TC)/ (HDL-C) also can be evaluated. The result shows that the detection ranges of biosensors are up to 300 mg/dL for free cholesterol, 500 mg/dL for cholesteryl ester, 750 mg/dL for triglyceride and 110 mg/dL for high density lipoprotein cholesterol. The detection ranges of these electrochemical biosensors are fit for the most clinical requirements. The detection limits according to priority are 17.6, 19.4, 28.2, and 23.2 mg/dL and the measurement time are 25, 20, 65, and 35 sec. These characteristics meet the requirement of clinical needs for lipid assessment.
author2 Meng Shan Lin
author_facet Meng Shan Lin
Wei Chung Shih
施偉仲
author Wei Chung Shih
施偉仲
spellingShingle Wei Chung Shih
施偉仲
Development of Lipid Panel Biosensors
author_sort Wei Chung Shih
title Development of Lipid Panel Biosensors
title_short Development of Lipid Panel Biosensors
title_full Development of Lipid Panel Biosensors
title_fullStr Development of Lipid Panel Biosensors
title_full_unstemmed Development of Lipid Panel Biosensors
title_sort development of lipid panel biosensors
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/58706271544596901094
work_keys_str_mv AT weichungshih developmentoflipidpanelbiosensors
AT shīwěizhòng developmentoflipidpanelbiosensors
AT weichungshih zhīzhìshēnghuàgǎncèqìzhīfāzhǎnyánjiū
AT shīwěizhòng zhīzhìshēnghuàgǎncèqìzhīfāzhǎnyánjiū
_version_ 1718304367575040000