Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires

碩士 === 國立成功大學 === 機械工程學系碩博士班 === 92 ===   With regard to a 10MW full-scale fire test facility, a series of calibration tests were carried out by means of gasoline pool fires. Various pool fire arrangements under different exhaust rates were conducted.   Heat release rate was computed with the follow...

Full description

Bibliographic Details
Main Authors: I-Fong Shiau, 蕭宜峰
Other Authors: none
Format: Others
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/z6mec4
id ndltd-TW-092NCKU5490019
record_format oai_dc
spelling ndltd-TW-092NCKU54900192019-05-15T20:21:37Z http://ndltd.ncl.edu.tw/handle/z6mec4 Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires 利用油盤火焰驗證10MW大尺度燃燒分析裝置 I-Fong Shiau 蕭宜峰 碩士 國立成功大學 機械工程學系碩博士班 92   With regard to a 10MW full-scale fire test facility, a series of calibration tests were carried out by means of gasoline pool fires. Various pool fire arrangements under different exhaust rates were conducted.   Heat release rate was computed with the following four methods. They are (1)oxygen consumption, (2)carbon dioxide generation, (3)gas temperature rise, and (4)mass reduction rate. The mass reduction rate of gasoline in the pool was measured with load cells; this method provided the basis of comparison for the first three methods. It was found in this study that the oxygen consumption method is more accurate than carbon dioxide generation method and is within 10% error in the range of 1~4MW heat release rate.   In the process of observation and analysis, the inter-relation among the following factors were recognized. These factors included flame appearance, fire products composition, exhaust rates, heat release rate, funnel-flame distance, and fuel pool arrangements. With this knowledge, some problems associated with the operation of the 10MW full-scale fire test facility were discussed and solutions suggested. none 林大惠 學位論文 ; thesis 137 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 機械工程學系碩博士班 === 92 ===   With regard to a 10MW full-scale fire test facility, a series of calibration tests were carried out by means of gasoline pool fires. Various pool fire arrangements under different exhaust rates were conducted.   Heat release rate was computed with the following four methods. They are (1)oxygen consumption, (2)carbon dioxide generation, (3)gas temperature rise, and (4)mass reduction rate. The mass reduction rate of gasoline in the pool was measured with load cells; this method provided the basis of comparison for the first three methods. It was found in this study that the oxygen consumption method is more accurate than carbon dioxide generation method and is within 10% error in the range of 1~4MW heat release rate.   In the process of observation and analysis, the inter-relation among the following factors were recognized. These factors included flame appearance, fire products composition, exhaust rates, heat release rate, funnel-flame distance, and fuel pool arrangements. With this knowledge, some problems associated with the operation of the 10MW full-scale fire test facility were discussed and solutions suggested.
author2 none
author_facet none
I-Fong Shiau
蕭宜峰
author I-Fong Shiau
蕭宜峰
spellingShingle I-Fong Shiau
蕭宜峰
Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires
author_sort I-Fong Shiau
title Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires
title_short Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires
title_full Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires
title_fullStr Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires
title_full_unstemmed Performance Evaluations on the 10MW Full-Scale Fire Test Facility by Using Oil-Pool Fires
title_sort performance evaluations on the 10mw full-scale fire test facility by using oil-pool fires
url http://ndltd.ncl.edu.tw/handle/z6mec4
work_keys_str_mv AT ifongshiau performanceevaluationsonthe10mwfullscalefiretestfacilitybyusingoilpoolfires
AT xiāoyífēng performanceevaluationsonthe10mwfullscalefiretestfacilitybyusingoilpoolfires
AT ifongshiau lìyòngyóupánhuǒyànyànzhèng10mwdàchǐdùránshāofēnxīzhuāngzhì
AT xiāoyífēng lìyòngyóupánhuǒyànyànzhèng10mwdàchǐdùránshāofēnxīzhuāngzhì
_version_ 1719097891144859648