The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy
碩士 === 國立中興大學 === 材料工程學研究所 === 92 === The purpose of this study was to improve the adhesion and corrosion resistance of hydroxyapatite(HA) on implant alloys, by electrolytic deposition of HA/TiO2 double layers coatings on Ti-6Al-4V alloys. The alloys were subjected to electrolytic deposition in a Ti...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2004
|
Online Access: | http://ndltd.ncl.edu.tw/handle/42294889864861959309 |
id |
ndltd-TW-092NCHU0159017 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-092NCHU01590172015-10-13T16:26:50Z http://ndltd.ncl.edu.tw/handle/42294889864861959309 The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy 電化學沈積HA/TiO2生醫陶瓷鍍膜於Ti-6Al-4V合金製程參數之研究 Rhelong Chen 陳瑞龍 碩士 國立中興大學 材料工程學研究所 92 The purpose of this study was to improve the adhesion and corrosion resistance of hydroxyapatite(HA) on implant alloys, by electrolytic deposition of HA/TiO2 double layers coatings on Ti-6Al-4V alloys. The alloys were subjected to electrolytic deposition in a TiCl4 alcoholic solution and subsequently in a mixed aqueous solution of Ca(NO3)2‧4H2O and NH4H2PO4 to form TiO(OH)2‧H2O interface layer and hydroxyapatite layer, respectively. Then the substrate was subjected to a low-temperature sintering process and transformed into a HA/TiO2 composite coating. The samples were characterized by XRD, SEM/EDS analysis; dynamic polarization tests; immersion tests; tensile tests; cell culture; and organ culture. The HA/TiO2 coated specimen revealed the better corrosion resistance than the HA and TiO2 coated or the uncoated. The adhesion strength of HA coatings on Ti-6Al-4V alloys were improved by the intermediate TiO2 coating. Also, immersion tests revealed the better bioactivity on HA/TiO2 or HA coated specimens than on the uncoated. Due to the best resistance and best bioactivity, the calvaria organ culture of HA/TiO2 also revealed the best osteoconduction. S. K. Yen 顏秀崗 2004 學位論文 ; thesis 155 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中興大學 === 材料工程學研究所 === 92 === The purpose of this study was to improve the adhesion and corrosion resistance of hydroxyapatite(HA) on implant alloys, by electrolytic deposition of HA/TiO2 double layers coatings on Ti-6Al-4V alloys. The alloys were subjected to electrolytic deposition in a TiCl4 alcoholic solution and subsequently in a mixed aqueous solution of Ca(NO3)2‧4H2O and NH4H2PO4 to form TiO(OH)2‧H2O interface layer and hydroxyapatite layer, respectively. Then the substrate was subjected to a low-temperature sintering process and transformed into a HA/TiO2 composite coating. The samples were characterized by XRD, SEM/EDS analysis; dynamic polarization tests; immersion tests; tensile tests; cell culture; and organ culture. The HA/TiO2 coated specimen revealed the better corrosion resistance than the HA and TiO2 coated or the uncoated. The adhesion strength of HA coatings on Ti-6Al-4V alloys were improved by the intermediate TiO2 coating. Also, immersion tests revealed the better bioactivity on HA/TiO2 or HA coated specimens than on the uncoated. Due to the best resistance and best bioactivity, the calvaria organ culture of HA/TiO2 also revealed the best osteoconduction.
|
author2 |
S. K. Yen |
author_facet |
S. K. Yen Rhelong Chen 陳瑞龍 |
author |
Rhelong Chen 陳瑞龍 |
spellingShingle |
Rhelong Chen 陳瑞龍 The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy |
author_sort |
Rhelong Chen |
title |
The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy |
title_short |
The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy |
title_full |
The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy |
title_fullStr |
The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy |
title_full_unstemmed |
The Study of Process Parameter of Electrolytic HA/TiO2 Bioceramic Coatings on Ti-6Al-4V alloy |
title_sort |
study of process parameter of electrolytic ha/tio2 bioceramic coatings on ti-6al-4v alloy |
publishDate |
2004 |
url |
http://ndltd.ncl.edu.tw/handle/42294889864861959309 |
work_keys_str_mv |
AT rhelongchen thestudyofprocessparameterofelectrolytichatio2bioceramiccoatingsonti6al4valloy AT chénruìlóng thestudyofprocessparameterofelectrolytichatio2bioceramiccoatingsonti6al4valloy AT rhelongchen diànhuàxuéchénjīhatio2shēngyītáocídùmóyúti6al4vhéjīnzhìchéngcānshùzhīyánjiū AT chénruìlóng diànhuàxuéchénjīhatio2shēngyītáocídùmóyúti6al4vhéjīnzhìchéngcānshùzhīyánjiū AT rhelongchen studyofprocessparameterofelectrolytichatio2bioceramiccoatingsonti6al4valloy AT chénruìlóng studyofprocessparameterofelectrolytichatio2bioceramiccoatingsonti6al4valloy |
_version_ |
1717771059159105536 |