Study and Implementation of a Single Phase Active Power Filter

碩士 === 崑山科技大學 === 電機工程研究所 === 92 === In this paper, It is not as same as traditional method to control real power or reactive power, we use the power balance idea to compensate harmonic and reactive current by Active Power Filter(APF). Current comes from using power electronic equipment results in h...

Full description

Bibliographic Details
Main Authors: Jhong-Kan Huang, 黃仲康
Other Authors: n
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/g23hne
id ndltd-TW-092KSUT5442022
record_format oai_dc
spelling ndltd-TW-092KSUT54420222019-05-15T20:33:45Z http://ndltd.ncl.edu.tw/handle/g23hne Study and Implementation of a Single Phase Active Power Filter 單相主動式電力濾波器之研製 Jhong-Kan Huang 黃仲康 碩士 崑山科技大學 電機工程研究所 92 In this paper, It is not as same as traditional method to control real power or reactive power, we use the power balance idea to compensate harmonic and reactive current by Active Power Filter(APF). Current comes from using power electronic equipment results in harmonic current and reactive power. After using APF to supply these current, the source current must be sine wave after compensating, and is in phase with source voltage. From the point of view “the APF forces the source current to be sine wave and in phase with source voltage”, then APF can compensate reactive power and eliminate harmonic current. It is not necessary to calculate average power through complicate process, the method and circuit will be more simple and less cost. n 陳金鈴 2004 學位論文 ; thesis 105 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 崑山科技大學 === 電機工程研究所 === 92 === In this paper, It is not as same as traditional method to control real power or reactive power, we use the power balance idea to compensate harmonic and reactive current by Active Power Filter(APF). Current comes from using power electronic equipment results in harmonic current and reactive power. After using APF to supply these current, the source current must be sine wave after compensating, and is in phase with source voltage. From the point of view “the APF forces the source current to be sine wave and in phase with source voltage”, then APF can compensate reactive power and eliminate harmonic current. It is not necessary to calculate average power through complicate process, the method and circuit will be more simple and less cost.
author2 n
author_facet n
Jhong-Kan Huang
黃仲康
author Jhong-Kan Huang
黃仲康
spellingShingle Jhong-Kan Huang
黃仲康
Study and Implementation of a Single Phase Active Power Filter
author_sort Jhong-Kan Huang
title Study and Implementation of a Single Phase Active Power Filter
title_short Study and Implementation of a Single Phase Active Power Filter
title_full Study and Implementation of a Single Phase Active Power Filter
title_fullStr Study and Implementation of a Single Phase Active Power Filter
title_full_unstemmed Study and Implementation of a Single Phase Active Power Filter
title_sort study and implementation of a single phase active power filter
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/g23hne
work_keys_str_mv AT jhongkanhuang studyandimplementationofasinglephaseactivepowerfilter
AT huángzhòngkāng studyandimplementationofasinglephaseactivepowerfilter
AT jhongkanhuang dānxiāngzhǔdòngshìdiànlìlǜbōqìzhīyánzhì
AT huángzhòngkāng dānxiāngzhǔdòngshìdiànlìlǜbōqìzhīyánzhì
_version_ 1719100798626955264