The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment

碩士 === 朝陽科技大學 === 環境工程與管理系碩士班 === 92 === Abstract Due to the rapid growth economy in Taiwan area (in recent years), largely water demand was increased. Facing the industrial vigorous development but the water resources actually decreased day by day. The insufficient water resources will affect the d...

Full description

Bibliographic Details
Main Authors: Shih-Chi Fang, 房士祺
Other Authors: Shu-Fen Cheng
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/xv9gaj
id ndltd-TW-092CYUT5087010
record_format oai_dc
spelling ndltd-TW-092CYUT50870102019-05-15T20:21:11Z http://ndltd.ncl.edu.tw/handle/xv9gaj The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment 電混凝處理方法對廢水處理效率提昇之研究 Shih-Chi Fang 房士祺 碩士 朝陽科技大學 環境工程與管理系碩士班 92 Abstract Due to the rapid growth economy in Taiwan area (in recent years), largely water demand was increased. Facing the industrial vigorous development but the water resources actually decreased day by day. The insufficient water resources will affect the development of economy continuously; therefore the topic of the technology of Waste Water Regeneration of Localization is so importance! (In domestic industry,) Electrocoagulation processes technology has been applied in wasted water processing in many years ago. But after the short period attempt, most domestic factories have discarded it currently. The main reasons are that the operating term of electrocoagulation processing system is difficult to control and the processing efficiency is extremely unstable. Electrocoagulation processes method not only change along with the water quality characteristics and the operation parameter, its processing efficiency of can have the quite big disparity, also its processing efficiency generally does not present the rule change along with the operation parameter change the tendency, therefore it needs to have Electrocoagulation processes mechanism quite clearly understanding in the actual utilization in order to achieve the best processing effect. This study uses each different water quality characteristic of waste water including COD waste water, and which contains waste water of the heavy metal to conducts Electrocoagulation processing research in order to understand the influence of each operation parameter during electrocoagulation processing. Discussion factors include operation voltage, resident time and pH value. Demonstrated by the findings that, following the increasing of the operation voltage and the resident time, pH value of the running water, the temperature, the soluble hard ion and the sludge quantity would increase as well as COD, BOD, SS would reduce. The result confirmed electrocoagulation method can be used in processing industrial waste water. In addition, the study integrate improvement method of zero- metal and electrocoagulation to discusses the promotion effect in the waste water processing efficiency. Its result is better than traditional electrocoagulation method. Shu-Fen Cheng 程淑芬 2004 學位論文 ; thesis 91 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 朝陽科技大學 === 環境工程與管理系碩士班 === 92 === Abstract Due to the rapid growth economy in Taiwan area (in recent years), largely water demand was increased. Facing the industrial vigorous development but the water resources actually decreased day by day. The insufficient water resources will affect the development of economy continuously; therefore the topic of the technology of Waste Water Regeneration of Localization is so importance! (In domestic industry,) Electrocoagulation processes technology has been applied in wasted water processing in many years ago. But after the short period attempt, most domestic factories have discarded it currently. The main reasons are that the operating term of electrocoagulation processing system is difficult to control and the processing efficiency is extremely unstable. Electrocoagulation processes method not only change along with the water quality characteristics and the operation parameter, its processing efficiency of can have the quite big disparity, also its processing efficiency generally does not present the rule change along with the operation parameter change the tendency, therefore it needs to have Electrocoagulation processes mechanism quite clearly understanding in the actual utilization in order to achieve the best processing effect. This study uses each different water quality characteristic of waste water including COD waste water, and which contains waste water of the heavy metal to conducts Electrocoagulation processing research in order to understand the influence of each operation parameter during electrocoagulation processing. Discussion factors include operation voltage, resident time and pH value. Demonstrated by the findings that, following the increasing of the operation voltage and the resident time, pH value of the running water, the temperature, the soluble hard ion and the sludge quantity would increase as well as COD, BOD, SS would reduce. The result confirmed electrocoagulation method can be used in processing industrial waste water. In addition, the study integrate improvement method of zero- metal and electrocoagulation to discusses the promotion effect in the waste water processing efficiency. Its result is better than traditional electrocoagulation method.
author2 Shu-Fen Cheng
author_facet Shu-Fen Cheng
Shih-Chi Fang
房士祺
author Shih-Chi Fang
房士祺
spellingShingle Shih-Chi Fang
房士祺
The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
author_sort Shih-Chi Fang
title The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
title_short The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
title_full The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
title_fullStr The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
title_full_unstemmed The study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
title_sort study of the efficiency elevation for modified electrocoagulation system on wastewater treatment
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/xv9gaj
work_keys_str_mv AT shihchifang thestudyoftheefficiencyelevationformodifiedelectrocoagulationsystemonwastewatertreatment
AT fángshìqí thestudyoftheefficiencyelevationformodifiedelectrocoagulationsystemonwastewatertreatment
AT shihchifang diànhùnníngchùlǐfāngfǎduìfèishuǐchùlǐxiàolǜtíshēngzhīyánjiū
AT fángshìqí diànhùnníngchùlǐfāngfǎduìfèishuǐchùlǐxiàolǜtíshēngzhīyánjiū
AT shihchifang studyoftheefficiencyelevationformodifiedelectrocoagulationsystemonwastewatertreatment
AT fángshìqí studyoftheefficiencyelevationformodifiedelectrocoagulationsystemonwastewatertreatment
_version_ 1719096761303171072